Haroon Asghar

Dr. Haroon Asghar

National Center for Physics, Islamabad, Islāmābād, Pakistan
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2015 in Spectrochimica Acta Part B: Atomic Spectroscopy
Verified
Journal Article
Closed access
JIJaved Iqbal
Javed Iqbal
SMS. Mahmood
S. Mahmood
ITIram Tufail
Iram Tufail
Haroon AsgharHaroon Asghar
Haroon Asghar
RAR. Ahmed
R. Ahmed
MBM.A. Baig
M.A. Baig

22 February 2023 in Heliyon
Verified
Journal Article
Open access
Amir FayyazAmir Fayyaz
Amir Fayyaz
Haroon AsgharHaroon Asghar
Haroon Asghar
AAA.M. Alshehri
A.M. Alshehri
TATahani A. Alrebdi
Tahani A. Alrebdi
In the present study, the immediate detection of rare-earth elements (REEs) in phosphorite deposits has been reported using laser-induced breakdown spectroscopy (LIBS). Numerous emission lines corresponding to the REEs such as lanthanum (La), cerium (Ce), neodymium (Nd), samarium (Sm), and ytterbium (Yb), have been detected in the emission spectra of phosphorite-induced plasma plume. For the quantitative analysis, we employed the calibration-free LIBS (CF-LIBS), and Energy Dispersive X-ray (EDX) spectroscopy techniques. The results obtained using the CF-LIBS technique show excellent agreement with that obtained by EDX. Besides principal component analysis (PCA) was employed by incorporating the LIBS spectral data of rare earth phosphorite rocks samples containing La, Ce, Nd, Sm, and Yb emission lines. The first three PCs were observed using LIBS spectral data set showing a covariance (interpretation rate) up to 76.3%. This study suggests that LIBS yields a quick and very reliable qualitative and quantitative analysis of REEs in any geological ore sample.

13 February 2018 in Optics Express
Verified
Journal Article
Closed access
PDF file
Haroon AsgharHaroon Asghar
Haroon Asghar
WWWei Wei
Wei Wei
PKPramod Kumar
Pramod Kumar
ESEhsan Sooudi
Ehsan Sooudi
JMJohn. G. McInerney
John. G. McInerney
We report experimental studies of the influence of symmetric dual-loop optical feedback on the RF linewidth and timing jitter of self-mode-locked two-section quantum dash lasers emitting at 1550 nm. Various feedback schemes were investigated and optimum levels determined for narrowest RF linewidth and low timing jitter, for single-loop and symmetric dual-loop feedback. Two symmetric dual-loop configurations, with balanced and unbalanced feedback ratios, were studied. We demonstrate that unbalanced symmetric dual loop feedback, with the inner cavity resonant and fine delay tuning of the outer loop, gives the narrowest RF linewidth and reduced timing jitter over a wide range of delay, unlike single and balanced symmetric dual-loop configurations. This configuration with feedback lengths of 80 and 140 m narrows the RF linewidth by ∼ 4–67x and ∼ 10–100x, respectively, across the widest delay range, compared to free-running. For symmetric dual-loop feedback, the influence of different power split ratios through the feedback loops was determined. Our results show that symmetric dual-loop feedback is markedly more effective than single-loop feedback in reducing RF linewidth and timing jitter, and is much less sensitive to delay phase, making this technique ideal for applications where robustness and alignment tolerance are essential.

3 April 2024 in Optical Fiber Technology
Verified
Journal Article
Closed access
HHHafsa Hameed
Hafsa Hameed
Haroon AsgharHaroon Asghar
Haroon Asghar
ULUsman Liaqat
Usman Liaqat
MSMuhammad Sohail
Muhammad Sohail
RARizwan Ahmed
Rizwan Ahmed
MBM. Aslam Baig
M. Aslam Baig

24 November 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Haroon AsgharHaroon Asghar
Haroon Asghar
RARizwan Ahmed
Rizwan Ahmed
RARizwan Ajmal
Rizwan Ajmal
ZUZeshan A. Umar
Zeshan A. Umar
JMJohn. G. McInerney
John. G. McInerney
MBM. Aslam Baig
M. Aslam Baig
In this paper, we present the performance and stability of an erbium-doped fiber laser (EDFL) based on ZnO saturable-absorber (SA) prepared using two schemes: solution method (SM) and pulsed laser deposition technique (PLDT). It was observed that EDFL with ZnO-SA prepared using SM emits at 1561.25 nm under a pump power of 230 mW. As the pump power is increased from 22.2 mW to 75.3 mW, the pulse duration decreases from 24.91 to 10.69 µs, and the pulse repetition rates increase from 11.59 to 40.91 kHz. Besides at pump power of 75.3 mW, the peak power, pulse energy, and average output power are measured as 0.327 mW, 2.86 nJ, and 0.18 mW, respectively. However, when PLDT-based SA was incorporated into the ring cavity, the emission wavelength is noticed at 1568.21 nm at a pump power of 230 mW. With the increase in pump power from 22.2 mW to 418 mW, the pulse repetition rates increase from 10.79 to 79.37 kHz and the pulse width decreases from 23.58 to 5.6 µs. Furthermore, the peak power, pulse energy, and average output power are observed to be 10.9 mW, 74 nJ, and 5.35 mW, respectively. The stability of EDFL based on SAs prepared using SM and PLDT has also been investigated. To the best of the author's knowledge, it is the first comparison of performance and long-term stability of EDFL based on two experimental techniques SM and PLDT-based SAs. These findings suggest that PLDT-based SAs provides optimum stability over a long period and enhanced the performance of fiber lasers compared to the SAs prepared using the conventional SM technique. This study paves the way for the development of ultra-stable SAs for their potential applications in pulsed laser sources and photonic devices.

28 May 2020 in Applied Optics
Verified
Journal Article
Closed access
JIJaved Iqbal
Javed Iqbal
Haroon AsgharHaroon Asghar
Haroon Asghar
SSS. K. H. Shah
S. K. H. Shah
MNM. Naeem
M. Naeem
SAShahab Abbasi
Shahab Abbasi
RARahel Ali
Rahel Ali
In this work, laser-induced breakdown spectroscopy (LIBS) has been used for the quantitative and qualitative analysis of the sage sample using the calibration-free LIBS (CF-LIBS) technique. The sage plasma is generated by focusing the second harmonics (532 nm) of a Q -switched Nd:YAG laser with a repetition rate of 10 Hz and pulse duration of 5 ns. The emission spectra are recorded using a LIBS 2000 detection system spectrometer consisting of five high-resolution spectrometers covering a wavelength range from 200 to 720 nm. The optical emission spectra of the sage sample reveal the spectral lines of Fe, Ca, Ti, Co, Mn, Ni, and Cr. The plasma temperature and electron number density of the neutral spectral lines of the pertinent elements have been deduced using the Boltzmann plot and Stark-broadening line profile method, with average values 8855 ± 885 K and 3.89 × 10 16 c m − 3 , respectively. The average values of the plasma parameters were used for the quantification of the detected elements in the sample. Based on the calibration-free method, the measured results demonstrate that Fe is the major constituent in the sample, having a percentage concentration of 48.1%, while the remaining elements are Ca, Ti, Co, Mn, Ni, and Cr, with percentage concentrations 0.7%, 5.3%, 8%, 11%, 12.3%, and 14.6%, respectively. This study demonstrates the feasibility of LIBS for the compositional analysis of major and trace elements present in the plant samples and its further applications in medicine.