The neuro-stimulant anti-narcoleptic drug as modafinil (MOD) is used to treatment neurological conditions caused by COVID-19. MOD was used to treatment narcolepsy, shift-work sleep disorder, and obstructive sleep apnea-related sleepiness. So, an innovative, quick, economical, selective, and ecologically friendly procedure was carried out. A highly sensitive N@CQDs technique was created from green Eruca sativa leaves in about 4 min using microwave synthesis at 700 w. The quantum yield of the synthesized N@CQDs was found to be 41.39%. By increasing the concentration of MOD, the quantum dots' fluorescence intensity was gradually quenched. After being excited at 445 nm, the fluorescence reading was recorded at 515 nm. The linear range was found to be in the range 50 – 700 ng mL−1 with lower limit of quantitation (LOQ) equal to 45.00 ng mL−1. The current method was fully validated and bio analytically according to (US-FDA and ICH) guidelines. Full characterization of the N@CQDs has been conducted by high resolution transmission electron microscope (HRTEM), Zeta potential measurement, fluorescence, UV–VIS, and FTIR spectroscopy. Various experimental variables including pH, QDs concentration and the reaction time were optimized. The proposed study is simply implemented for the therapeutic drug monitoring system (TDMS) and various clinical laboratories for further pharmacokinetic research.
The COVID-19 pandemic has encouraged the search for novel antiviral medications. Recently, molnupiravir (MOL) has been approved as an oral antiviral to manage COVID-19. Thus, the development of sensitive and cost-effective methods for quantification of MOL in real plasma samples (pharmacokinetic) and pharmaceutical tablets is required. Herein, we present the fabrication of novel fluorescent polyamine quantum dots (PA@CQDs) fabricated from apricots using one step synthesis for analysis of MOL. The relative fluorescence intensity (RFI) of the synthesized quantum dots was influentially quenched by the addition of molnupiraivr. The linear range was found to be between 2–70 ng mL−1 with lower limit of quantitation (LOQ) equal to 1.61 ng mL−1. The fluorescent probe was successfully utilized in a pharmacokinetic study of MOL with maximum plasma concentration (Cmax) 920.2 ± 6.12 ng mL−1 without any matrix interference. The sensitivity and selectivity of the presented method allow its application in clinical laboratories.
Vonoprazan (VON) has been approved recently via US-FDA in 2015 as the first in class of potassium competitive acid blocker group. VON is used for management of GIT ulcer, reflux esophagitis and for eradication of Helicobacter pylori. So, the first spectrofluorimetric method was developed for estimation of VON in real human plasma and content uniformity test. The fluorimetric methodology based on reaction of secondary amine group in VON with benzofurazan (0.05% w/v NBD-Cl) reagent as nucleophilic substitution reaction in alkaline medium (0.1 M borate buffer pH 8.2) to produce highly fluorescent product measure at 530 nm after excitation at 465 nm. The linear calibration range was found 15 to 200 ng mL−1 with lower limit of quantitation (LOQ) equal to 8.57 ng mL−1. The method was successfully applied for estimation of VON in pharmacokinetic (PK) and content uniformity studies. The maximum plasma concentration was found to be (Cmax) 71.03 ng mL−1 after maximum time (tmax) equal to 1.5 ± 0.15 h. The presented strategy also applied to ensure concentration of drug in each tablet using content uniformity test with high percent of recovery 100.05 ± 0.66. The proposed method was established for clinical laboratories and therapeutic drug monitoring studies.