Caroline Holtkamp

Dr. Caroline Holtkamp


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2021 in Pathogens
Verified
Journal Article
Open access
PDF file
MFMelanie Fiedler
Melanie Fiedler
CHCaroline Holtkamp
Caroline Holtkamp
UDUlf Dittmer
Ulf Dittmer
OAOlympia Anastasiou
Olympia Anastasiou
We aimed to evaluate the LIAISON® SARS-CoV-2 antigen assay (DiaSorin), comparing its performance to real-time polymerase chain reaction (RT-PCR) for the detection of SARS-CoV-2 RNA. 182 (110 PCR-positive and 72 PCR-negative) nasopharyngeal swab samples were taken for the detection of SARS-CoV-2. RT-PCR and antigen assay were performed using the same material. The sensitivity and specificity of the antigen assay were calculated for different cut-offs, with RT-PCR serving as the reference method. Stored clinical samples that were positive for other respiratory viruses were tested to evaluate cross-reactivity. One third (33/110, 30%) were falsely classified as negative, while no false positives were found using the 200 TCID50/mL cut-off for the SARS-CoV-2 antigen as proposed by the manufacturer. This corresponded to a sensitivity of 70% (60–78%) and a specificity of 100% (94–100%). Lowering the cut-off for positivity of the antigen assay to 22.79 or 57.68 TCID50/mL increased the sensitivity of the method, reaching a sensitivity of 92% (85–96%) vs. 79% (70–86%) and a specificity of 81% (69–89%) vs. 99% (91–100%), respectively. The antigen assay reliably detected samples with high SARS-CoV-2 viral loads (≥106 copies SARS-CoV-2/mL), while it cannot differentiate between negative and low positive samples. Cross-reactivity toward other respiratory viruses was not detected.

18 January 2022 in Vaccines
Verified
Journal Article
Open access
PDF file
CHCaroline Holtkamp
Caroline Holtkamp
MFMelanie Fiedler
Melanie Fiedler
UDUlf Dittmer
Ulf Dittmer
OAOlympia Anastasiou
Olympia Anastasiou
Hepatitis B virus infection results in the appearance of anti-HBc antibodies that normally persist lifelong. We analyzed the course of anti-HBc antibodies overtime, focusing on patients with a permanent loss or fluctuating anti-HBc antibodies. From 120,531 patients tested for anti-HBc antibodies (Architect, Abbott) from January 2006 to December 2020, ≥4 serial values were available in 8098 and permanent or intermittent anti-HBc loss was observed in 139 patients. It was relatively frequent in baseline anti-HBc positive, immunocompromised patients with available serial measurements of anti-HBc overtime (13% of hematologic/oncologic patients, 10% of solid organ transplant recipients, and 6% of HIV patients compared to 3% in patients with other diseases). In the same period, 12,607 samples were tested for HBsAg, anti-HBc antibodies, and HBV DNA—in nine cases we detected HBV DNA with undetectable anti-HBc and HBsAg. In four out of nine cases contamination of the PCR during processing was the likeliest cause, in another four, no further data were available, while in one the HBV DNA was later followed by a temporary anti-HBc seroconversion. In conclusion, permanent or intermittent anti-HBc loss is more common in immunocompromised hosts than in patients with other underlying diseases. Furthermore, anti-HBc and HBsAg assays can be safely used to exclude an active HBV infection, even in immunocompromised hosts.

29 April 2021 in Viruses
Verified
Journal Article
Open access
PDF file
OAOlympia Anastasiou
Olympia Anastasiou
CHCaroline Holtkamp
Caroline Holtkamp
MSMiriam Schäfer
Miriam Schäfer
FSFrieda Schön
Frieda Schön
AEAnna Maria Eis-Hübinger
Anna Maria Eis-Hübinger
AKAndi Krumbholz
Andi Krumbholz
The availability of simple SARS-CoV-2 detection methods is crucial to contain the COVID-19 pandemic. This study examined whether a commercial LAMP assay can reliably detect SARS-CoV-2 genomes directly in respiratory samples without having to extract nucleic acids (NA) beforehand. Nasopharyngeal swabs (NPS, n = 220) were tested by real-time reverse transcription (RT)-PCR and with the LAMP assay. For RT-PCR, NA were investigated. For LAMP, NA from 26 NPS in viral transport medium (VTM) were tested. The other 194 NPS were analyzed directly without prior NA extraction (140 samples in VTM; 54 dry swab samples stirred in phosphate buffered saline). Ten NPS were tested directly by LAMP using a sous-vide cooking unit. The isothermal assay demonstrated excellent specificity (100%) but moderate sensitivity (68.8%), with a positive predictive value of 1 and a negative predictive value of 0.65 for direct testing of NPS in VTM. The use of dry swabs, even without NA extraction, improved the analytical sensitivity; up to 6% of samples showed signs of inhibition. LAMP could be performed successfully with a sous-vide cooking unit. This technique is very fast, requires little laboratory resources, and can replace rapid antigen tests or verify reactive rapid tests on-site.