Background and Objectives: Prematurity of birth occurs before the 37th week of gestation and affects up to 10% of births worldwide. It is correlated with critical outcomes; therefore, constant monitoring in neonatal intensive care units or home environments is required. The aim of this work was to develop solutions for remote neonatal intensive supervision systems, which should assist medical diagnosis of premature infants and raise alarm at cardiac abnormalities, such as bradycardia. Additionally, the COVID-19 pandemic has put a worldwide stress upon the medical staff and the management of healthcare units. Materials and Methods: A traditional medical diagnosing scheme was set up, implemented with the aid of powerful mathematical operators. The algorithm was tailored to the infants’ personal ECG characteristics and was tested on real ECG data from the publicly available PhysioNet database “Preterm Infant Cardio-Respiratory Signals Database”. Different processing problems were solved: noise filtering, baseline drift removal, event detection and compression of medical data using the à trous wavelet transform. Results: In all 10 available clinical cases, the bradycardia events annotated by the physicians were correctly detected using the RR intervals. Compressing the ECG signals for remote transmission, we obtained compression ratios (CR) varying from 1.72 to 7.42, with the median CR value around 3. Conclusions: We noticed that a significant amount of noise can be added to a signal while monitoring using standard clinical sensors. We tried to offer solutions for these technical problems. Recent studies have shown that persons infected with the COVID-19 disease are frequently reported to develop cardiovascular symptoms and cardiac arrhythmias. An automatic surveillance system (both for neonates and adults) has a practical medical application. The proposed algorithm is personalized, no fixed reference value being applied, and the algorithm follows the neonate’s cardiac rhythm changes. The performance depends on the characteristics of the input ECG. The signal-to-noise ratio of the processed ECG was improved, with a value of up to 10 dB.
1 January 2020 in Advances in Electrical and Computer Engineering
Cardiac anomalies are usually marked through irregular cardiac cycles. Atrial fibrillation is given through a rapid beating of the atria, announcing a possible heart failure or stroke. ...
(1) Background: The prevention of critical situations is a key ability in medicine. Hip ultrasound for neonates is a standard procedure to prevent later critical outcomes, such as hip dysplasia. Additionally, the SARS-CoV-2 pandemic has put worldwide stress upon healthcare units, resulting often in a lack of sufficient medical personnel. This work aims to develop solutions to ease and speed up the process of coming to a correct diagnosis. (2) Methods: Traditional medical procedures are envisaged, but they are enhanced to reduce diagnosing errors due to the movements of the neonates. Echographic noise filtering and contrast correction methods are implemented the Hyperanalytic Wavelet Transform, combined with an adaptive Soft Thresholding Filter. The algorithm is tailored to infants’ structure and is tested on real ultrasounds provided by the “Victor Babes” University of Medicine and Pharmacy. Denoising and contrast correction problems are targeted. (3) Results: In available clinical cases, the noise affecting the image was reduced and the contrast was enhanced. (4) Discussion: We noticed that a significant amount of noise can be added to the image, as the patients are neonates and can hardly avoid movements. (5) Conclusions: The algorithm is personalized with no fixed reference value. Any device easing the clinical procedures of physicians has a practical medical application.