Mathias Busek

Dr. Mathias Busek

Institute of Basic Medical Science, Hybrid Technology Hub - Centre of Excellence, University Oslo, 0130 Oslo, Norway

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2022 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
Mathias BusekMathias Busek
Mathias Busek
AAAleksandra Aizenshtadt
Aleksandra Aizenshtadt
TKTimo Koch
Timo Koch
AFAnna Frank
Anna Frank
LDLudivine Delon
Ludivine Delon
SKStefan Krauss
Stefan Krauss
We present a novel pump-less Organ-on-a-Chip (OoC) platform featuring organoid embedding, functional vascular components, and recirculation of (immune) cells in a scalable and robust configuration.

19 May 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
Mathias BusekMathias Busek
Mathias Busek
SNSteffen Nøvik
Steffen Nøvik
AAAleksandra Aizenshtadt
Aleksandra Aizenshtadt
MAMikel Amirola-Martinez
Mikel Amirola-Martinez
TCThomas Combriat
Thomas Combriat
SKStefan Krauss
Stefan Krauss
Polydimethylsiloxane (PDMS) has been used in microfluidic systems for years, as it can be easily structured and its flexibility makes it easy to integrate actuators including pneumatic pumps. In addition, the good optical properties of the material are well suited for analytical systems. In addition to its positive aspects, PDMS is well known to adsorb small molecules, which limits its usability when it comes to drug testing, e.g., in organ-on-a-chip (OoC) systems. Therefore, alternatives to PDMS are in high demand. In this study, we use thermoplastic elastomer (TPE) films thermally bonded to laser-cut poly(methyl methacrylate) (PMMA) sheets to build up multilayered microfluidic devices with integrated pneumatic micro-pumps. We present a low-cost manufacturing technology based on a conventional CO2 laser cutter for structuring, a spin-coating process for TPE film fabrication, and a thermal bonding process using a pneumatic hot-press. UV treatment with an Excimer lamp prior to bonding drastically improves the bonding process. Optimized bonding parameters were characterized by measuring the burst load upon applying pressure and via profilometer-based measurement of channel deformation. Next, flow and long-term stability of the chip layout were measured using microparticle Image Velocimetry (uPIV). Finally, human endothelial cells were seeded in the microchannels to check biocompatibility and flow-directed cell alignment. The presented device is compatible with a real-time live-cell analysis system.

16 February 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Mathias BusekMathias Busek
Mathias Busek
AAAleksandra Aizenshtadt
Aleksandra Aizenshtadt
MAMikel Amirola-Martinez
Mikel Amirola-Martinez
LDLudivine Delon
Ludivine Delon
SKStefan Johannes Karl Krauss
Stefan Johannes Karl Krauss
Organ-on-a-Chip (OoC) systems bring together cell biology, engineering, and material science for creating systems that recapitulate the in vivo microenvironment of tissues and organs. The versatility of OoC systems enables in vitro models for studying physiological processes, drug development, and testing in both academia and industry. This paper evaluates current platforms from the academic end-user perspective, elaborating on usability, complexity, and robustness. We surveyed 187 peers in 35 countries and grouped the responses according to preliminary knowledge and the source of the OoC systems that are used. The survey clearly shows that current commercial OoC platforms provide a substantial level of robustness and usability—which is also indicated by an increasing adaptation of the pharmaceutical industry—but a lack of complexity can challenge their use as a predictive platform. Self-made systems, on the other hand, are less robust and standardized but provide the opportunity to develop customized and more complex models, which are often needed for human disease modeling. This perspective serves as a guide for researchers in the OoC field and encourages the development of next-generation OoCs.

2 May 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
ABAnthony Beck
Anthony Beck
FOFranziska Obst
Franziska Obst
Mathias BusekMathias Busek
Mathias Busek
SGStefan Grünzner
Stefan Grünzner
Philipp MehnerPhilipp Mehner
Philipp Mehner
Andreas RichterAndreas Richter
Andreas Richter
The interest in large-scale integrated (LSI) microfluidic systems that perform high-throughput biological and chemical laboratory investigations on a single chip is steadily growing. Such highly integrated Labs-on-a-Chip (LoC) provide fast analysis, high functionality, outstanding reproducibility at low cost per sample, and small demand of reagents. One LoC platform technology capable of LSI relies on specific intrinsically active polymers, the so-called stimuli-responsive hydrogels. Analogous to microelectronics, the active components of the chips can be realized by photolithographic micro-patterning of functional layers. The miniaturization potential and the integration degree of the microfluidic circuits depend on the capability of the photolithographic process to pattern hydrogel layers with high resolution, and they typically require expensive cleanroom equipment. Here, we propose, compare, and discuss a cost-efficient do-it-yourself (DIY) photolithographic set-up suitable to micro-pattern hydrogel-layers with a resolution as needed for very large-scale integrated (VLSI) microfluidics. The achievable structure dimensions are in the lower micrometer scale, down to a feature size of 20 µm with aspect ratios of 1:5 and maximum integration densities of 20,000 hydrogel patterns per cm². Furthermore, we demonstrate the effects of miniaturization on the efficiency of a hydrogel-based microreactor system by increasing the surface area to volume (SA:V) ratio of integrated bioactive hydrogels. We then determine and discuss a correlation between ultraviolet (UV) exposure time, cross-linking density of polymers, and the degree of immobilization of bioactive components.

18 October 2013 in Journal of Sensors and Sensor Systems
Verified
Journal Article
Open access
PDF file
Mathias BusekMathias Busek
Mathias Busek
MNM. Nötzel
M. Nötzel
CPC. Polk
C. Polk
FSF. Sonntag
F. Sonntag
The aim of the work is to find an analytical model of a pneumatic micropump which was integrated into a cell-culture system. This allows the estimation of peak velocities and wall-shear stress influencing the cultured cells in our multi-organ-chip (MOC) with respect to the applied pressure and the geometric properties of the pump. By adjusting those parameters, one can imitate physiological or pathological heart activity. The calculated flow within the MOC was compared to experimental results obtained via the non-invasive micro-PIV method.

1 September 2016 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
Mathias BusekMathias Busek
Mathias Busek
SGStefan Grünzner
Stefan Grünzner
TSTobias Steege
Tobias Steege
UKUdo Klotzbach
Udo Klotzbach
FSFrank Sonntag
Frank Sonntag
In this work a microfluidic cell cultivation device for perfused hypoxia assays as well as a suitable controlling unit are presented. The device features active components like pumps for fluid actuation and valves for fluid direction as well as an oxygenator element to ensure a sufficient oxygen transfer. It consists of several individually structured layers which can be tailored specifically to the intended purpose. Because of its clearness, its mechanical strength and chemical resistance as well as its well-known biocompatibility polycarbonate was chosen to form the fluidic layers by thermal diffusion bonding. Several oxygen sensing spots are integrated into the device and monitored with fluorescence lifetime detection. Furthermore an oxygen regulator module is implemented into the controlling unit which is able to mix different process gases to achieve a controlled oxygenation. First experiments show that oxygenation/deoxygenation of the system is completed within several minutes when pure nitrogen or air is applied to the oxygenator. Lastly the oxygen input by the pneumatically driven micro pump was quantified by measuring the oxygen content before and after the oxygenator.