Issa Pour-Ghaz

Dr. Issa Pour-Ghaz


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Annals of Translational Medicine
Verified
Journal Article
Closed access
PDF file
JRJoel M. Raja
Joel M. Raja
CECarol Elsakr
Carol Elsakr
SRSherif Roman
Sherif Roman
BCBrandon Cave
Brandon Cave
IPIssa Pour-Ghaz
Issa Pour-Ghaz
RKRami N. Khouzam
Rami N. Khouzam
Atrial fibrillation (AF) poses a major health concern in the United States by affecting over 5 million people accounting for at least 15% to 25% of strokes. It can be asymptomatic or subclinical with its first presentation being stroke in 18%, and AF being only detected at the time of stroke. With evidence of subclinical AF associated with increased risk of ischemic stroke, recent developments indeed point towards wearables, especially smart watches, being quite effective and representing a novel method for screening for silent AF in the general population, and thereby reducing mortality and morbidity associated with it. This manuscript aims to review whether the photoplethysmography (PPG) technology, employed in the wearables to monitor heart rate, is accurate enough to aid in the diagnosis of AF that may remain asymptomatic or paroxysmal. It also explores the option of actually employing this method in the general population, the feasibility of this mode of diagnosis, sensitivity and specificity of this method compared to the conventional electrocardiogram (EKG), and the actual follow up with a practitioner and subsequent treatment of AF, if diagnosed. We conducted a Medline search using various combinations of “smart watch” “atrial fibrillation” “wearables”, and “Kardia” to identify pivotal randomized trials published before June 1, 2019, for inclusion in this review. Concurrently, major practice guidelines, trial bibliographies, and pertinent reviews were examined to ensure inclusion of relevant trials. A consensus among the authors was used to choose items for narrative inclusion. The following section reviews data from pivotal trials to determine the effectiveness of smart watch technology in detecting AF in the general population. Trials reviewed evaluated apple watch, Kardia, Samsung wearables in diagnosis of AF. The fact that there is an increase in consumer use of wearables, smart devices, which can serve as health monitoring devices that can be used as a non-invasive, ambulatory assessment of heart rate and rhythm, is definitely novel. Intermittent short EKG recordings repeated over a longer-term period produced significantly better sensitivity for AF detection, with 4 times as many cases diagnosed compared with a single time-point measurement. Since there are limitations and further research into this new field is required, the wearable technology may not serve as the ultimate tool for diagnosis of AF, rather a nidus for the general population to seek medical advice for confirmation on being notified of having an irregular rhythm leading to prevention of morbidity and mortality associated with it.

1 September 2019 in Annals of Translational Medicine
Verified
Journal Article
Closed access
PDF file
IPIssa Pour-Ghaz
Issa Pour-Ghaz
TMTheodore Manolukas
Theodore Manolukas
NFNathalie Foray
Nathalie Foray
JRJoel Raja
Joel Raja
ARAranyak Rawal
Aranyak Rawal
RKRami N. Khouzam
Rami N. Khouzam
One of the most important variables in assessing hemodynamic status in the intensive care unit (ICU) is the cardiac function and blood pressure. Invasive methods such as pulmonary artery catheter and arterial line allow monitoring of blood pressure and cardiac function accurately and reliably. However, their use is not without drawbacks, especially when the invasive nature of these procedures and complications associated with them are considered. There are several newer methods of noninvasive and minimally invasive hemodynamic monitoring available. In this manuscript, we will review these different methods of minimally invasive and non-invasive hemodynamic monitoring and will discuss their advantages, drawbacks and limitations.

3 January 2014 in The FASEB Journal
Verified
Journal Article
Open access
PDF file
GKGergely Kiss
Gergely Kiss
CKCsaba Konrad
Csaba Konrad
IPIssa Pour-Ghaz
Issa Pour-Ghaz
JMJosef J. Mansour
Josef J. Mansour
BNBéata Németh
Béata Németh
Christos ChinopoulosChristos Chinopoulos
Christos Chinopoulos
Substrate‐level phosphorylation mediated by succinyl‐CoA ligase in the mitochondrial matrix produces high‐energy phosphates in the absence of oxidative phosphorylation. Furthermore, when the electron transport chain is dysfunctional, provision of succinyl‐CoA by the a‐ketoglutarate dehydrogenase complex (KGDHC) is crucial for maintaining the function of succinyl‐CoA ligase yielding ATP, preventing the adenine nucleotide translocase from reversing. We addressed the source of the NAD + supply for KGDHC under anoxic conditions and inhibition of complex I. Using pharmacologic tools and specific substrates and by examining tissues from pigeon liver exhibiting no diaphorase activity, we showed that mitochondrial diaphorases in the mouse liver contribute up to 81% to the NAD + pool during respiratory inhibition. Under these conditions, KGDHC's function, essential for the provision of succinyl‐CoA to succinyl‐CoA ligase, is supported by NAD + derived from diaphorases. Through this process, diaphorases contribute to the maintenance of substrate‐level phosphorylation during respiratory inhibition, which is manifested in the forward operation of adenine nucleotide translocase. Finally, we show that reoxidation of the reducible substrates for the diaphorases is mediated by complex III of the respiratory chain.—Kiss, G., Konrad, C., Pour‐Ghaz, I., Mansour, J. J., Nemeth, B., Starkov, A A., Adam‐Vizi, V., Chinopoulos, C. Mitochondrial diaphorases as NAD + donors to segments of the citric acid cycle that support substrate‐level phosphorylation yielding ATP during respiratory inhibition. FASEB J. 28, 28–1682 (1697). www.fasebj.org

1 September 2019 in Annals of Translational Medicine
Verified
Journal Article
Open access
PDF file
IPIssa Pour-Ghaz
Issa Pour-Ghaz
DHDavid Hana
David Hana
JRJoel Raja
Joel Raja
UIUzoma N. Ibebuogu
Uzoma N. Ibebuogu
RKRami N. Khouzam
Rami N. Khouzam
The prevalence of heart failure (HF) has been on the rise with associated increase in hospitalizations, morbidity and mortality. These hospitalizations have led to increasingly more cost on and decreased quality of life for patients. CardioMEMS is one of the newer devices designed to help tackle this issue by allowing for better monitoring of HF patients. This device also allows for accurate recording of pulmonary artery pressures (PAPs) and has also been applied in various other areas, such as aneurysmal tears, for monitoring pressures. In this manuscript we will review the current state of CardioMEMS HF system and investigate some of the other areas for its promising use in the field.

19 August 2022 in Current Problems in Cardiology
Verified
Journal Article
Closed access
IPIssa Pour-Ghaz
Issa Pour-Ghaz
ABAnandbir Bath
Anandbir Bath
SKSharif Kayali
Sharif Kayali
DADeya Alkhatib
Deya Alkhatib
NYNeeraja Yedlapati
Neeraja Yedlapati
MNMannu Nayyar
Mannu Nayyar

1 January 2018 in Annals of Translational Medicine
Verified
Journal Article
Closed access
PDF file
TBTamunoinemi Bob-Manuel
Tamunoinemi Bob-Manuel
ANAmit Nanda
Amit Nanda
SLSamuel Latham
Samuel Latham
IPIssa Pour-Ghaz
Issa Pour-Ghaz
WIWilliam Paul Skelton Iv
William Paul Skelton Iv
RKRami N. Khouzam
Rami N. Khouzam
Conduction abnormalities are a common and serious complication of transcatheter aortic valve replacement (TAVR) with well-established predictive factors. Current guidelines are not concrete, leaving several questions unanswered about indications, timing and risks of pacemaker implantation post-TAVR. In this review article, we discuss current guidelines, predictors of pacemaker implantation, clinical implications of this procedure and our recommendations for reducing the pacemaker implantation rate post-TAVR.