Marlies Gijs

Dr. Marlies Gijs

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Experimental Eye Research
Verified
Journal Article
Closed access
CBChristian J.F. Bertens
Christian J.F. Bertens
MGMarlies Gijs
Marlies Gijs
FBFrank Van Den Biggelaar
Frank Van Den Biggelaar
RNRudy M.M.A. Nuijts
Rudy M.M.A. Nuijts

22 November 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MGMarlies Gijs
Marlies Gijs
IRInez H. G. B. Ramakers
Inez H. G. B. Ramakers
PVPieter Jelle Visser
Pieter Jelle Visser
FVFrans R. J. Verhey
Frans R. J. Verhey
MWMarjo P. H. van de Waarenburg
Marjo P. H. van de Waarenburg
CWCarroll A. B. Webers
Carroll A. B. Webers
There has been increasing interest in finding non-invasive biomarkers for neurodegenerative diseases such as Alzheimer’s disease (AD). This observational study investigated AD-specific biomarkers in tear fluid. Tear fluid was collected from a total of 65 subjects, including 23 patients with subjective cognitive decline (SCD), 22 patients with mild cognitive impairment (MCI), 11 dementia patients and 9 healthy controls (HC). Levels of amyloid-beta peptides (AB38, AB40, AB42), total-tau (t-tau) and phosphorylated-tau (p-tau) were determined using multiplex immunoassays. Levels of AB40 and t-tau were detectable in the vast majority (> 94%) of tear fluid samples. Cerebrospinal fluid (CSF) was available from a subset of patients. In this group, tear t-tau levels were significantly higher in people with dementia compared to SCD patients. Tear t-tau levels were elevated in patients with neurodegeneration (classified according to the A/T/N system) compared to patients without neurodegeneration. Negative correlations were found between CSF AB42 and CSF t-tau, and between CSF AB42 and tear t-tau. In summary, this study shows the potential of tau proteins in tear fluid to be associated with disease severity and neurodegeneration.

24 January 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MGMarlies Gijs
Marlies Gijs
SASinthuja Arumugam
Sinthuja Arumugam
NSNienke van de Sande
Nienke van de Sande
CWCarroll A. B. Webers
Carroll A. B. Webers
SSSwaminathan Sethu
Swaminathan Sethu
RNRudy M. M. A. Nuijts
Rudy M. M. A. Nuijts
Tear fluid is emerging as a source of non-invasive biomarkers, both for ocular and systemic conditions. Accurate quantification of tear proteins can be improved by standardizing methods to collect and process tear fluid. The aim of this study was to determine sample handling factors that may influence the tear protein biomarker profile. Tear fluid was collected using Schirmer’s strips. Tear proteins were extracted by elution through centrifugation. Total protein content was determined using the bicinchoninic acid assay. Key concepts that apply to the entire sample processing cycle are tear sampling, tear storage, protein extraction and data normalization. Differences in wetting or migration length were observed between Schirmer’s strips from different manufacturers, and between protein-free and protein-rich solutions. One unit of migration length (mm) did not correspond to one unit of volume (µL). A positive correlation (r = 0.6671, p < 0.0001) was observed between migration length and total tear protein content. The most beneficial storage conditions were strips that were not stored (+ 21.8%), or underwent ‘wet’ storage (+ 11.1%). Protein recovery was the highest in 400 µL extraction buffer and independent of protein molecular weight. This study helps to explain inter- and intra-variability that is often seen with tear biomarker research. This information is critical to ensure accuracy of test results, as tear biomarkers will be used for patient management and in clinical trials in the near future. This study also highlights the need for standardization of Schirmer’s strip manufacturing, tear fluid processing and analyte concentration normalization.

13 February 2025 in Progress in Retinal and Eye Research
Verified
Journal Article
Open access
MGMarlies Gijs
Marlies Gijs
NSNienke van de Sande
Nienke van de Sande
CBClémence Bonnet
Clémence Bonnet
JSJente Schmeetz
Jente Schmeetz
RFRosa Fernandes
Rosa Fernandes
SJStephanie C. Joachim
Stephanie C. Joachim
Tear fluid is an emerging source of disease biomarkers, drawing attention due to its quick, inexpensive, and non-invasive collection. The advancements in detection techniques enable the measurement of ultra-low biomarker levels from small sample volumes typical of tear fluid. The lack of standardized protocols for collection, processing, and analysis of tear fluid remains a significant challenge. To address this, we convened the Tear Research Network Review Taskforce in 2022 to review protocols from the past three decades, providing a comprehensive overview of the methodologies used in tear fluid biomarker research. A total of 1484 articles published from January 1974 to May 2024 from two electronic databases, Embase and Ovid MEDLINE, were reviewed. An exponential increase in the number of articles on tear fluid biomarkers was observed from 2015 onwards. The two most commonly reported collection methods were; glass capillaries (45.2%), and Schirmer's strips (25%), with glass capillary tube collection remaining the most frequent method until 2019, when Schirmer's strips became the leading method. Most articles analyzed tear fluid proteins (65%) and focused on a single analyte (32.3%). In recent years, an increase was observed in the type and number of examined analytes. The differences in the reported methodologies and protocols underscore the need for standardization and harmonization within the field of tear fluid biomarkers to minimize methodological differences and reduce variability in clinical outcomes. Consistent and detailed reporting is essential for improving the reproducibility and validity of tear fluid studies, in order to advance their potential clinical applications.

19 May 2016 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
MGMarlies Gijs
Marlies Gijs
GPGregory Penner
Gregory Penner
GBGarth B. Blackler
Garth B. Blackler
NINathalie R.E.N. Impens
Nathalie R.E.N. Impens
Sarah BaatoutSarah Baatout
Sarah Baatout
AAAn M. Aerts
An M. Aerts
Aptamers provide a potential source of alternative targeting molecules for existing antibody diagnostics and therapeutics. In this work, we selected novel DNA aptamers targeting the HER2 receptor by an adherent whole-cell SELEX approach. Individual aptamers were identified by next generation sequencing and bioinformatics analysis. Two aptamers, HeA2_1 and HeA2_3, were shown to bind the HER2 protein with affinities in the nanomolar range. In addition, both aptamers were able to bind with high specificity to HER2-overexpressing cells and HER2-positive tumor tissue samples. Furthermore, we demonstrated that aptamer HeA2_3 is being internalized into cancer cells and has an inhibitory effect on cancer cell growth and viability. In the end, we selected novel DNA aptamers with great potential for the diagnosis and possible treatment of HER2-positive cancer.

1 December 2023 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
MGMarlies Gijs
Marlies Gijs
TATuneille I. Adelaar
Tuneille I. Adelaar
DVDaphne P. C. Vergouwen
Daphne P. C. Vergouwen
NVNienke Visser
Nienke Visser
MDMor M. Dickman
Mor M. Dickman
RNRudy M. M. A. Nuijts
Rudy M. M. A. Nuijts
Purpose: Keratoconus is characterized by the progressive thinning of the cornea, which leads to a cone-like appearance of the eye over time. Although conventionally defined as a noninflammatory condition, a number of recent studies have associated keratoconus (KC) with allergic conjunctivitis (AC) based on clinical parameters. This study aimed to consolidate this association by performing a proteomic analysis of tear fluid from patients with keratoconus and/or allergic conjunctivitis. Methods: Of 51 patients, 17 were diagnosed with KC, 17 were diagnosed with AC, and 17 were diagnosed with both KC and AC (combined). Nine of 34 patients with KC had a progressive form of the disease. Tear fluid samples (n = 51, one eye per patient) were collected by the Schirmer's strips. Tear proteins were extracted from the Schirmer's strips. Proteomic profiling of 384 inflammatory proteins was assessed by a multiplex proximity extension assay (Olink Explore 384 Inflammation Panel I). Results: A total of 384 inflammatory proteins were measured. Two hundred seventy-two of the 384 proteins passed stringent data cleaning and were compared among the patient groups. Compared to the 2 other groups, LGALS9 was upregulated uniquely in KC, whereas FGF19, PDGFB, HPCAL1, OSM, and FCAR were downregulated in KC. Similarly, TNFRSF4 and CCL13 were specifically upregulated in AC, whereas ectodysplasin A receptor (EDAR) was uniquely downregulated in AC. Conclusions: High-throughput proteomic profiling of tear fluid confirms the association between KC and AC on a molecular level and raise the importance of redefining KC as an inflammatory condition.