Do-Heon Gu

Dr. Do-Heon Gu


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
DGDo-Heon Gu
Do-Heon Gu
CECheolsoo Eo
Cheolsoo Eo
SHSeung-A Hwangbo
Seung-A Hwangbo
SHSung-Chul Ha
Sung-Chul Ha
JKJin Hong Kim
Jin Hong Kim
SPSuk-Youl Park
Suk-Youl Park
BL-11C, a new protein crystallography beamline, is an in-vacuum undulator-based microfocus beamline used for macromolecular crystallography at the Pohang Accelerator Laboratory and it was made available to users in June 2017. The beamline is energy tunable in the range 5.0–20 keV to support conventional single- and multi-wavelength anomalous-dispersion experiments against a wide range of heavy metals. At the standard working energy of 12.659 keV, the monochromated beam is focused to 4.1 µm (V) × 8.5 µm (H) full width at half-maximum at the sample position and the measured photon flux is 1.3 × 1012 photons s−1. The experimental station is equipped with a Pilatus3 6M detector, a micro-diffractometer (MD2S) incorporating a multi-axis goniometer, and a robotic sample exchanger (CATS) with a dewar capacity of 90 samples. This beamline is suitable for structural determination of weakly diffracting crystalline substances, such as biomaterials, including protein, nucleic acids and their complexes. In addition, serial crystallography experiments for determining crystal structures at room temperature are possible. Herein, the current beamline characteristics, technical information for users and some recent scientific highlights are described.

21 January 2026 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
DGDo-Heon Gu
Do-Heon Gu
DADanny Axford
Danny Axford
JBJames Beilsten-Edmands
James Beilsten-Edmands
SJSofia Jaho
Sofia Jaho
RORobin L. Owen
Robin L. Owen
Serial synchrotron crystallography (SSX) enables structure determination from microcrystals under near-physiological, room-temperature conditions but is limited in part due to the inevitable onset of radiation damage. The ability to reduce the absorbed dose while retaining, or even improving, data quality is an attractive means of mitigating this limitation. Advances in detector technology have made the use of high-energy X-rays a routine approach in MX, improving diffraction efficiency and enhancing overall data quality. Here, we systematically evaluate low-dose SSX data collected at five different X-ray energies from 12.4 to 25 keV using a CdTe Eiger2 detector while maintaining a constant dose. Higher photon energies increased the mean diffracted intensity and signal-to-noise ratio per unit dose, and facilitated higher-resolution structure determination, even with limited crystal numbers. These findings highlight the advantages of high-energy X-rays and provide practical guidance for optimizing SSX experiments in probing protein dynamics.

5 June 2026 in IUCrJ
Verified
Journal Article
Open access
JKJos J. A. G. Kamps
Jos J. A. G. Kamps
PHPhilip Hinchliffe
Philip Hinchliffe
JGJohan Glerup
Johan Glerup
EFEmily I. Freeman
Emily I. Freeman
PLPauline Lang
Pauline Lang
PAPierre Aller
Pierre Aller
We describe the design and implementation of a drop-on-fixed-target method for time-resolved serial crystallography at both synchrotron and XFEL facilities. A piezoelectric droplet dispensing pipette is employed for addition of picolitre volume aqueous droplets (∼40–90 pl; ∼40–55 µm diameter sphere), containing (co-)substrate(s) or ligand(s), onto enzyme microcrystals previously loaded into the trapezoidal wells of an etched crystalline silicon fixed-target chip containing 25 600 wells in a high-density, square grid with 125 µm centre-to-centre well spacing. These features demand exquisite accuracy and thereby constrain motion controls to enable robust time-resolved crystallographic studies. The system was tested with three enzyme systems, comprising lysozyme and two β-lactamases, CTX-M-15 and AmpC EC . Mitigation strategies for cross-well contamination, including the implementation of interleaved controls, are described; the overall performance of the system at synchrotron and X-ray free-electron laser facilities was evaluated. This drop-on-fixed-target method is a reliable framework for time-resolved crystallography and will improve the consistency of measurements across facilities.

3 February 2025 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
DGDo-Heon Gu
Do-Heon Gu
DJDong Tak Jeong
Dong Tak Jeong
CECheolsoo Eo
Cheolsoo Eo
PSPil-Won Seo
Pil-Won Seo
JKJeong-Sun Kim
Jeong-Sun Kim
SPSuk-Youl Park
Suk-Youl Park
Synchrotron serial crystallography (SSX) is an emerging method for determining crystal structure at room temperature using synchrotron radiation facilities. Despite the various approaches available, reducing sample consumption, removing mother liquid from crystal solution, soaking small molecules for protein–ligand complex structure and prevention of sample dehydration are still challenging problems to be overcome in SSX. Therefore, we have developed a new flip-type fixed-target SSX sample holder for conventional protein crystallography beamlines based on nylon mesh and kapton film. The potential of the flip-holder was evaluated in an SSX experiment with lysozyme crystals at room temperature. About 19600 diffraction images were collected during 40 minutes using a repetition rate of 10 Hz at the 11C beamline of the Pohang Accelerator Laboratory, and the crystal structure of lysozyme was determined at 1.89 Å resolution. This straightforward flip-holder can be used in synchrotron beamlines for routine crystallography.

19 December 2025 in bioRxiv
Verified
Preprint
Open access
JKJos J. A. G. Kamps
Jos J. A. G. Kamps
PHPhilip Hinchliffe
Philip Hinchliffe
JGJohan Glerup
Johan Glerup
EFEmily I. Freeman
Emily I. Freeman
PLPauline Lang
Pauline Lang
PAPierre Aller
Pierre Aller
We describe the design and implementation of a drop on fixed target method for time-resolved serial crystallography at both synchrotron and XFEL facilities. A piezoelectric droplet dispensing pipette is employed for addition of picolitre volume (40 - 90 pL) aqueous droplets, containing (co-)substrate(s) or ligand(s), onto enzyme microcrystals immobilised on a solid support. The system was tested with various enzyme systems, including lysozyme and two beta-lactamases, CTX-M-15 and AmpC. Mitigation strategies for cross-well contamination, including the implementation of interleaved controls, are described; the overall performance of the system at synchrotron and X-ray free electron laser facilities was evaluated. This drop on fixed target method is a reliable framework for time-resolved crystallography and will improve the consistency of measurements across facilities.

19 December 2025 in bioRxiv
Verified
Preprint
Open access
PHPhilip Hinchliffe
Philip Hinchliffe
CTCatherine L Tooke
Catherine L Tooke
MBMichael Beer
Michael Beer
PAPierre Aller
Pierre Aller
JKJos Jag Kamps
Jos Jag Kamps
JSJames Spencer
James Spencer
β-Lactamases catalyze β-lactam antibiotic hydrolysis and are important contributors to bacterial antimicrobial resistance; β-lactamase inhibitors are widely used to overcome β-lactamase-mediated antibiotic resistance. Nucleophilic serine β-lactamases (SBLs) react with their substrates and clinically available inhibitors via a covalent reaction to give complexes which can undergo further reaction. Using room temperature drop on fixed target serial crystallography, where ligands are rapidly mixed with microcrystals, and classical single-crystal crystallography at cryogenic temperatures, we investigate the reversible covalent reaction of the SBL CTX-M-15 with the diazobicyclooctane inhibitor avibactam. We observe avibactam covalently reacted (ring-opened) with the nucleophilic Ser70, at timepoints from 80 ms to minutes (room temperature) and hours (100 K). These crystallographic data reveal time-dependent movement of the avibactam carbamoyl complex, from 1.3 s onwards, that has implications for the 5-exo-trig recyclization mechanism that determines inhibitor reformation. Combined with molecular dynamics simulations and quantum mechanics calculations at the density functional theory level, the results show that in the first seconds of the reaction the avibactam N-sulfate nitrogen is poorly positioned for recyclization. This subsequently equilibrates after 10 s to a stable endpoint that is in a conformation potentially primed to initiate recyclization through attack of the N-sulfate nitrogen on the carbamoyl carbon. These results further demonstrate the capacity of room-temperature serial crystallography to capture time-resolved changes in ligand conformation at an enzyme active site, complementing discrete classical cryo-crystallography. These data inform on ligand dynamics and the stereoelectronics of diazobicyclooctane inhibition, aiding drug discovery efforts to develop inhibitors of nucleophilic enzymes.