Application of microfluidics to Positron Emission Tomography (PET) tracer synthesis has attracted increasing interest within the last decade. The technical advantages of microfluidics, in particular the high surface to volume ratio and resulting fast thermal heating and cooling rates of reagents can lead to reduced reaction times, increased synthesis yields and reduced by-products. In addition automated reaction optimization, reduced consumption of expensive reagents and a path towards a reduced system footprint have been successfully demonstrated. The processing of radioactivity levels required for routine production, use of microfluidic-produced PET tracer doses in preclinical and clinical imaging as well as feasibility studies on autoradiolytic decomposition have all given promising results. However, the number of microfluidic synthesizers utilized for commercial routine production of PET tracers is very limited. This study reviews the state of the art in microfluidic PET tracer synthesis, highlighting critical design aspects, strengths, weaknesses and presenting several characteristics of the diverse PET market space which are thought to have a significant impact on research, development and engineering of microfluidic devices in this field. Furthermore, the topics of batch- and single-dose production, cyclotron to quality control integration as well as centralized versus de-centralized market distribution models are addressed.
Causal associations between microglia activation and β-amyloid (Aβ) accumulation during the progression of Alzheimer’s disease (AD) remain a matter of controversy. Therefore, we used longitudinal dual tracer in vivo small animal positron emission tomography (μPET) imaging to resolve the progression of the association between Aβ deposition and microglial responses during aging of an Aβ mouse model. APP-SL70 mice (N = 17; baseline age 3.2–8.5 months) and age-matched C57Bl/6 controls (wildtype (wt)) were investigated longitudinally for 6 months using Aβ (18F-florbetaben) and 18 kDa translocator protein (TSPO) μPET (18F-GE180). Changes in cortical binding were transformed to Z-scores relative to wt mice, and microglial activation relative to amyloidosis was defined as the Z-score difference (TSPO—Aβ). Using 3D immunohistochemistry for activated microglia (Iba-1) and histology for fibrillary Aβ (methoxy-X04), we measure microglial brain fraction relative to plaque size and the distance from plaque margins. Aβ-PET binding increased exponentially as a function of age in APP-SL70 mice, whereas TSPO binding had an inverse U-shape growth function. Longitudinal Z-score differences declined with aging, suggesting that microglial response declined relative to increasing amyloidosis in aging APP-SL70 mice. Microglial brain volume fraction was inversely related to adjacent plaque size, while the proximity to Aβ plaques increased with age. Microglial activity decreases relative to ongoing amyloidosis with aging in APP-SL70 mice. The plaque-associated microglial brain fraction saturated and correlated negatively with increasing plaque size with aging.
24 March 2022 in European Journal of Nuclear Medicine and Molecular Imaging
Background: [68Ga]Ga-FAPI-46 is a novel positron emission tomography (PET) ligand that targets fibroblast activation protein (FAP) expression as FAP inhibitor (FAPI) and could already show promising results in several tumor entities. It could be demonstrated that an increased FAP expression correlates with tumor aggressivity in urothelial carcinoma (UC). Given the limited value of [18F]FDG in UC, [68Ga]Ga-FAPI-46 could add diagnostic information in staging and response assessment in UC. We present the first data of [68Ga]Ga-FAPI-46 PET imaging in a pilot cohort of UC patients evaluating uptake characteristics in metastases and primary tumors. Methods: Fifteen patients with UC prior to or after local treatment underwent [68Ga]Ga-FAPI-46 PET/CT imaging for detection of metastatic spread. We compared the biodistribution in non-affected organs and tumor uptake of UC lesions by standard uptake value measurements (SUVmean and SUVmax). Additionally, metastatic sites on PET were compared to its morphological correlate on contrast-enhanced computed tomography (CT). Results: Overall, 64 tumor sites were detected on PET and/or CT. The highest uptake intensity was noted at the primary site (SUVmax 20.8 (range, 8.1–27.8)) followed by lymph node metastases (SUVmax 10.6 (range, 4.7–29.1)). In 4/15 (26.7%) patients there were [68Ga]Ga-FAPI-46-positive lesions that were missed on standard routine CT imaging. On the other hand, 2/15 patients had suspicious prominent bipulmonary nodules as well as pelvic lymph nodes previously rated as suspicious for metastatic spread on CT, but without increased FAPI expression; here histopathology excluded malignancy. Conclusion: [68Ga]Ga-FAPI-46 PET shows distinctly elevated uptake in UC lesions. Therefore, the tracer has potential as a promising new biomarker in metastatic UC patients, as [68Ga]Ga-FAPI-46 PET might improve detection of metastatic sites compared to CT alone. These findings highly emphasize larger studies investigating FAPI imaging in UC patients.
Triggering receptor expressed on myeloid cells 2 (TREM2) plays an essential role in microglia activation and is being investigated as a potential therapeutic target for modulation of microglia in several neurological diseases. In this study, we present the development and preclinical evaluation of 64Cu-labeled antibody-based PET radiotracers as tools for non-invasive assessment of TREM2 expression. Furthermore, we tested the potential of an antibody transport vehicle (ATV) that binds human transferrin receptor to facilitate transcytosis of TREM2 antibody-based radiotracers to the CNS and improve target engagement.