Liqui-pellet is a new dosage form stemming from pelletisation technology and concept from liquisolid technology. In spite of liqui-pellet overcoming a major hurdle in liquisolid technology through achieving excellent flow property with high liquid load factor, the formulation requires to be optimised in order to improve drug release rate. Liqui-pellets of naproxen containing Tween 80, Primojel, Avicel and Aerosil were extruded and spheronised. Flowability test confirmed that all liqui-pellet formulations have excellent-good flow property (Carr’s index between 3.9–11.17%), including liqui-pellets with a high liquid load factor of 1.52, where 38% of the total mass is co-solvent. This shows a relatively high liquid load factor can be achieved in liqui-pellet without compromising the flowability, which is one of the key novelty of this work. It was found that the improved drug release rate was due to the remarkably improved disintegration of the supposedly non-disintegrating microcrystalline-based pellet; the optimised liqui-pellet seems to explode into fragments in the dissolution medium. At pH 1.2, the optimised formulation had ~ 10% more drug release than non-optimised formulation after 2 h, and at pH 7.4, the drug release of the optimised pellet was nearing 100% at ~ 15 min, whereas the none-optimised pellet only achieved ~ 79% drug release after 2 h. DSC and XRPD indicated an increase in the dissolution rate could be due to molecularly dispersion of naproxen in the pellets. Overall results showed that liqui-pellet exhibited an enhanced drug release and the capacity for high liquid load factor whilst maintaining excellent flowability, rendering it a potentially commercially feasible drug delivery system.
The dissolution profile is of great importance in drug delivery and is affected by the manufacturing method. Thus, it is important to study the influence of the thermal process on drug release in emerging technologies such as 3D printing-fused deposition modeling (FDM). For this purpose, the characteristics of 3D printed tablets were compared to those of tablets prepared by other thermal methods such as hot-melt extrusion (HME) and non-thermal methods such as physical mixture (PM). Theophylline was used as a drug model and blends of ethyl cellulose (EC) and hydroxypropyl cellulose (HPC) were used as a matrix former. The solid state of the drug in all formulations was investigated by differential scanning calorimetry, X-ray powder diffraction, and Fourier-transformed infrared spectroscopy. All studied tablets had the same weight and surface area/volume (SA/V). Dissolution data showed that, for some formulations, printed tablets interestingly had a faster release profile despite having the highest hardness values (>550 N) compared to HME and PM tablets. Porosity investigations showed that 100% infill printed tablets had the highest porosity (~20%) compared to HME (<10%) and PM tablets (≤11%). True density records were the lowest in printed tablets (~1.22 g/m3) compared to tablets made from both HME and PM methods (~1.26 g/m3), reflecting the possible increase in polymer specific volume while printing. This increase in the volume of polymer network may accelerate water and drug diffusion from/within the matrix. Thus, it is a misconception that the 3D printing process will always retard drug release based on increased tablet hardness. Hardness, porosity, density, solid-state of the drug, SA/V, weight, and formulation components are all factors contributing to the release profile where the total balance can either slow down or accelerate the release profile.
8 April 2024 in Pharmaceutical Development and Technology
One of the widely used approaches for improving the dissolution of poorly water-soluble drugs is particle size reduction. Ball milling is a mechanical, top-down technique used to reduce particle size. The effect of ball number, ball size and milling speed on the properties of milled Aprepitant is evaluated. A full factorial design was employed to investigate the influence of affecting factors on particle size reduction. The initial suspension was made by suspending the drug in distilled water using excipients followed by milling in a planetary ball mill. Ball size, ball number and milling speed modulated particle size distribution of Aprepitant. Increasing the number of balls from minimum to maximum for each ball size led to approximately a 28% reduction in mean particle size, a 37% decrease in D90%, and a 25% decrease in the ratio of volume mean particle diameter to numeric mean particle diameter. On average, using 10 mm balls instead of 30 mm balls reduced mean particle size by 1.689 µm. As a result, ball size, ball number, and milling speed are three effective factors in the process of ball milling. By increasing the ball number and decreasing the ball size, efficient micronization of drug particles takes place and the particle size is more uniform.
Aim: Liqui-Pellet is potentially an emerging next-generation oral pill, which has shown promising results with unique advantages as well as displaying potential for commercial feasibility. Since Liqui-Pellet technology is still in its infancy, it is important to explore the parameters that can affect its performance, particularly the drug release rate. Therefore, the aim of this study is to investigate thoroughly the effect of Avicel PH101 (carrier) and Aerosil 300 (coating material) ratio (R-value) in Liqui-Pellet. Methods: Key parameter for Liqui-Pellet formulation in this study was the ratio of carrier and coating material. Tests were carried out to assess the physicochemical properties of different formulations. This involved looking into particle size, robustness, flowability, solid-state and drug release profile. The morphology of Liqui-Pellet was investigated by SEM. Results: It is found that R-value does not have a major effect on the success of Liqui-Pellet production. However, R-value does seem to have an effect on Liqui-Pellet size at a certain water content level and a slight effect on the drug release rate. A decrease in Avicel PH101 concentration and an increase in Aerosil 300 concentration in Liqui-Pellet formulations can reduce Liqui-Pellet size and slightly increase drug release rate by 9% after 2 h. The data shows Liqui-Pellet is resistant to friability, able to achieve exceptional flow property and have smooth surfaces, which is critical for applying coatings technology. Such properties are ideal in terms of commercial manufacturing. The XRPD and DSC both show the reduction in formulation crystallinity, which is expected in Liqui-Pellet formulation as a result of solubility of the drug in the co-solvent used in the preparation of Liqui-Pellets. Conclusion: Overall it seems that R-value can affect Liqui-Pellet drug release rate and size but not on the production success rate. Graphical