The purpose of this study was to investigate the effectiveness of preemptive analgesia with nonsteroidal anti-inflammatory drugs (NSAIDs) in third-molar surgery. A PubMed literature search was conducted for articles restricted to the English language using the following terms (DeCS/MeSH) or combinations: analgesia, third molar, and preemptive. From a total of 704 articles, 6 (n = 420 subjects) were selected. All studies presented a low risk of bias (Cochrane criteria) but exhibited high heterogeneity of methods. Two studies were excluded from the meta-analysis because they did not have adequate numeric values (dichotomous data) for the calculations. Preemptive analgesia showed no significant benefit (n = 298, P = .2227, odds ratio: 2.30, 0.60–8.73) in reducing postoperative pain after removal of lower impacted third molars. However, there was a probable direct relationship between the effectiveness of NSAIDs in preemptive analgesia for removal of third molars and its selectivity for the cyclooxygenase-2 (COX-2). Preemptive analgesia did not have a significant effect in reducing postoperative pain after removal of lower impacted third molars. More homogeneous and well-delineated clinical studies are necessary to determine a possible association between NSAIDs' selectivity for COX-2 and treatment effectiveness.
Oral cancer is a significant cause of morbidity and mortality, and has a poor prognosis. This has encouraged additional studies into factors that may affect the development of this disease. The biological behavior of malignant neoplasms is complex. Studies have investigated the energy metabolism of tumor cells, in an endeavor to elucidate the tumor biology. The identification of molecular signatures and mechanisms, in order to understand tumor progression, may facilitate the identification of novel predictive and prognostic markers. Pathways that influence tumor progression, such as those involving hypoxia‑inducible factor (HIF) and glucose transporter (GLUT) proteins, have been the targets of recent studies.
Objectives: To summarize the evidence on the feasibility of maxillomandibular imaging exams-related fractal dimension (FD) in screening patients with osteoporosis. Methods: This registered systematic review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses of Diagnostic Test Accuracy statement. High sensitivity search strategies were developed for six primary databases and grey literature. Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) items evaluated the risk of bias, and the GRADE approach assessed the evidence certainty. Results: From 1034 records initially identified through database searching, four studies were included (total sample of 747 patients [osteoporosis, 136; control group, 611]). The meta-analysis showed that the overall sensitivity and specificity of the FD were 86.17 and 72.68%, respectively. In general, all studies showed low RoB and applicability concern. The certainty of the evidence was very low to moderate. Conclusions: This systematic review showed that the jaw-related FD presented sensitivity and specificity values higher than 70%, and its sensitivity in osteoporosis screening was a better parameter than specificity.
PURPOSE: To conduct a systematized review of the literature about the main local hemostatic measures to control postoperative bleeding in anticoagulated patients. METHODS: A systematized review of literature was performed in the electronic database Medline (PubMed) without restriction of the publication date. The eligibility criteria were studies involving maintenance of the anticoagulant therapy, prospective studies, retrospective studies, randomized clinical trials, controlled clinical studies, comparative studies, multicentric studies or case-control studies. Studies discontinuing anticoagulant therapy, case reports, literature reviews, in vitro studies, animal experiments and articles written in language not compatible with the search strategy adopted in this work were excluded. RESULTS: Twenty-four articles that met the adopted eligibility criteria were selected, enrolling 3891 subjects under anticoagulant therapy. A total of 171 cases of hemorrhage was observed. Tranexamic acid was the main local hemostatic measure used to controlling of postoperative bleeding. CONCLUSION: The local hemostatic measures proved to be effective according to previously published studies. Nevertheless, further clinical studies should be conducted to confirm this effectiveness.
Objectives: To evaluate the accuracy of the measurements of the maxillary sinus (MS) and frontal sinus (FS) in sex estimation among Brazilian adults using multislice computed tomography (MCT) and to develop and cross-validate a new formula for sex estimation.Methods: The present cross-sectional research was conducted in two phases: (1) development of a formula on the basis of the measurements of both the sinuses (50 males and 50 females); and (2) validation study (20 males and 20 females). The linear measurements (height, width and diameter) were assessed using the RadiAnt DICOM software. A new formula for sex estimation was developed (multivariate statistical approach) and validated. Receiver operating characteristic curves, area under the curve, sensitivity, specificity, positive and negative predictive values, accuracy and likelihood ratio were estimated.Results: Males displayed higher mean values (width, height and diameter) of the FS and MS (p < 0.05). The MS was a better predictor in sex estimation (males vs females), compared to the FS (accuracy between 61–74% and 58–69%, respectively). The distance between the right and left MS displayed the highest accuracy (74%). The sensitivity, specificity and accuracy of the new formula were 80%, 95.5% and 87.5%, respectively. 63.1% reduction was observed in the number of predictive values for sex estimation (individuals older than 30 years).Conclusions: The present MCT measurements showed a higher accuracy in the estimation of sex in males. The highest accuracy was associated with the distance between the right and left MS. The new formula displayed high precision for sex estimation.