Albert Omlor

Dr. Albert Omlor


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2019 in Respiratory Research
Verified
Journal Article
Open access
PDF file
OCon behalf of the German COSYCONET consortium
on behalf of the German COSYCONET consortium
FTFranziska C. Trudzinski
Franziska C. Trudzinski
MAMohamad Alqudrah
Mohamad Alqudrah
AOAlbert Omlor
Albert Omlor
SZStephen Zewinger
Stephen Zewinger
RBRobert Bals
Robert Bals
The combination of chronic obstructive pulmonary disease (COPD) and chronic kidney disease (CKD) is associated with a higher prevalence of comorbidities and increased mortality. The impact of kidney function on patient-centered outcomes in COPD has not been evaluated. Patients from the German COPD and Systemic Consequences - Comorbidities Network (COSYCONET) cohort COPD were analysed. CKD was diagnosed if the estimated glomerular filtration rate (eGFR) measurements were < 60 mL/min/1.73m2 at study inclusion and six month later. The effect of CKD, on comorbidities, symptoms [modified British Medical Research Council dyspnoea scale], physical capacity [six-minute walk test, and timed up and go] and St George’s Respiratory Questionnaire were analysed. Restricted cubic spline models were used to evaluate a nonlinear relationship between eGFR with patient-centered outcomes, cox survival analysis was applied to evaluate mortality. 2274 patients were analysed, with CKD diagnosed in 161 (7.1%). Spline models adjusted for age, gender, BMI, FEV1 and cardiovascular comorbidities revealed independent associations between eGFR with modified British Medical Research Council dyspnoea scale, St George’s Respiratory Questionnaire, (p < 0.001 and p = 0.011), six-minute walk test (p = 0.015) and timed up and go (p < 0.001). CKD was associated with increased mortality, independently from for other cardiovascular comorbidities (hazard ratio 2.3; p < 0.001). These data show that CKD is a relevant comorbidity in COPD patients which impacts on patient-centered outcomes and mortality. NCT01245933

30 April 2022 in Membranes
Verified
Journal Article
Open access
PDF file
SCStefan Caspari
Stefan Caspari
LSLeonie S. Schwärzel
Leonie S. Schwärzel
AJAnna M. Jungmann
Anna M. Jungmann
NSNicole Schmoll
Nicole Schmoll
FSFrederik Seiler
Frederik Seiler
AOAlbert Omlor
Albert Omlor
Extracorporeal membrane oxygenation (ECMO) has become an important therapeutic approach in the COVID-19 pandemic. The development and research in this field strongly relies on animal models; however, efforts are being made to find alternatives. In this work, we present a new mock circuit for ECMO that allows measurements of the oxygen transfer rate of a membrane lung at full ECMO blood flow. The mock utilizes a large reservoir of heparinized porcine blood to measure the oxygen transfer rate of the membrane lung in a single passage. The oxygen transfer rate is calculated from blood flow, hemoglobin value, venous saturation, and post-membrane arterial oxygen pressure. Before the next measuring sequence, the blood is regenerated to a venous condition with a sweep gas of nitrogen and carbon dioxide. The presented mock was applied to investigate the effect of a recirculation loop on the oxygen transfer rate of an ECMO setup. The recirculation loop caused a significant increase in post-membrane arterial oxygen pressure (paO2). The effect was strongest for the highest recirculation flow. This was attributed to a smaller boundary layer on gas fibers due to the increased blood velocity. However, the increase in paO2 did not translate to significant increases in the oxygen transfer rate because of the minor significance of physically dissolved oxygen for gas transfer. In conclusion, our results regarding a new ECMO mock setup demonstrate that recirculation loops can improve ECMO performance, but not enough to be clinically relevant.

27 May 2021 in Membranes
Verified
Journal Article
Open access
PDF file
LSLeonie S. Schwärzel
Leonie S. Schwärzel
AJAnna M. Jungmann
Anna M. Jungmann
NSNicole Schmoll
Nicole Schmoll
SCStefan Caspari
Stefan Caspari
FSFrederik Seiler
Frederik Seiler
AOAlbert Omlor
Albert Omlor
Extracorporeal carbon dioxide removal (ECCO2R) is an important technique to treat critical lung diseases such as exacerbated chronic obstructive pulmonary disease (COPD) and mild or moderate acute respiratory distress syndrome (ARDS). This study applies our previously presented ECCO2R mock circuit to compare the CO2 removal capacity of circular versus parallel-plated membrane lungs at different sweep gas flow rates (0.5, 2, 4, 6 L/min) and blood flow rates (0.3 L/min, 0.9 L/min). For both designs, two low-flow polypropylene membrane lungs (Medos Hilte 1000, Quadrox-i Neonatal) and two mid-flow polymethylpentene membrane lungs (Novalung Minilung, Quadrox-iD Pediatric) were compared. While the parallel-plated Quadrox-iD Pediatric achieved the overall highest CO2 removal rates under medium and high sweep gas flow rates, the two circular membrane lungs performed relatively better at the lowest gas flow rate of 0.5 L/min. The low-flow Hilite 1000, although overall better than the Quadrox i-Neonatal, had the most significant advantage at a gas flow of 0.5 L/min. Moreover, the circular Minilung, despite being significantly less efficient than the Quadrox-iD Pediatric at medium and high sweep gas flow rates, did not show a significantly worse CO2 removal rate at a gas flow of 0.5 L/min but rather a slight advantage. We suggest that circular membrane lungs have an advantage at low sweep gas flow rates due to reduced shunting as a result of their fiber orientation. Efficiency for such low gas flow scenarios might be relevant for possible future portable ECCO2R devices.

24 September 2023 in Membranes
Verified
Journal Article
Open access
PDF file
AOAlbert Omlor
Albert Omlor
SCStefan Caspari
Stefan Caspari
LOLeonie S. Omlor
Leonie S. Omlor
AJAnna M. Jungmann
Anna M. Jungmann
MKMarcin Krawczyk
Marcin Krawczyk
PLPhilipp M. Lepper
Philipp M. Lepper
Extracorporeal membrane oxygenation (ECMO) is an important rescue therapy method for the treatment of severe hypoxic lung injury. In some cases, oxygen saturation and oxygen partial pressure in the arterial blood are low despite ECMO therapy. There are case reports in which patients with such instances of refractory hypoxemia received a second membrane lung, either in series or in parallel, to overcome the hypoxemia. It remains unclear whether the parallel or serial connection is more effective. Therefore, we used an improved version of our full-flow ECMO mock circuit to test this. The measurements were performed under conditions in which the membrane lungs were unable to completely oxygenate the blood. As a result, only the photometric pre- and post-oxygenator saturations, blood flow and hemoglobin concentration were required for the calculation of oxygen transfer rates. The results showed that for a pre-oxygenator saturation of 45% and a total blood flow of 10 L/min, the serial connection of two identical 5 L rated oxygenators is 17% more effective in terms of oxygen transfer than the parallel connection. Although the idea of using a second membrane lung if refractory hypoxia occurs is intriguing from a physiological point of view, due to the invasiveness of the solution, further investigations are needed before this should be used in a wider clinical setting.

28 September 2019 in European Respiratory Journal
Verified
Conference Paper
Closed access
AOAlbert Omlor
Albert Omlor
FTFranziska Trudzinski
Franziska Trudzinski
MAMohamad Alqudrah
Mohamad Alqudrah
FSFrederik Seiler
Frederik Seiler
FBFrank Biertz
Frank Biertz
RBRobert Bals
Robert Bals
High resting heart rate (RHR) is associated with higher mortality in general population and in cardiovascular disease. Less is known about the association of RHR with outcome in chronic obstructive pulmonary disease (COPD). This study investigated the influence of RHR on survival of 2741 COPD patients in the multicentre cohort study COSYCONET (German COPD and Systemic Consequences – Comorbidities Network). Patients with a baseline RHR >72 beats per minute (bbp) had a significantly (p=0.049) higher all-cause mortality risk (adjusted hazard ratio (HR) of 1.37 (1.00-1.87) compared to baseline RHR 72 bpm separates risk more precisely (HR 1.82, 1.22-2.50, p=0.0001) than baseline RHR. In conclusion, an increased RHR is independently associated with a higher mortality in patients with COPD. These results show that RHR, especially time-updated RHR, represents an independent predictor for mortality in COPD. Whether RHR is a treatment target needs to be proven in controlled trials.