Muhammed Ayas

Dr. Muhammed Ayas

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2020 in F1000Research
Verified
Journal Article
Open access
PDF file
MAMuhammed Ayas
Muhammed Ayas
AAAhmad Mohd Haider Ali Al Amadi
Ahmad Mohd Haider Ali Al Amadi
DKDuaa Khaled
Duaa Khaled
AAAhmad Munzer Alwaa
Ahmad Munzer Alwaa
Background: The COVID-19 pandemic has affected the world in an unprecedented manner. It has aggravated psychological distress in parents of children with cochlear implants. Continuous use of a speech sound processor is critical for auditory stimulation in children with cochlear implants. However, movement restrictions imposed have affected access to hearing healthcare services. The current study explores the impact of the COVID-19 pandemic on hearing healthcare access for children with cochlear implants. Methods: An online questionnaire survey was conducted among parents of children with cochlear implants. Results: A total of 24 parents responded to the questionnaire. All the respondents reported that COVID-19 has a significant impact on access to hearing health services for their children. Speech processor breakdown and disconnection from the auditory mode of communication had a critical influence on behavioral changes in children. Conclusions: The current study highlights the hurdles faced by the parents in order to access hearing health services for their children. The use of innovative methods such as remote tele-audiology will be the way forward to tackle challenges faced by the parents.

MAMuhammed Ayas
Muhammed Ayas
HYHakam Yaseen
Hakam Yaseen
The successful implementation of pediatric audiology services depends on parental engagement and support. It is essential to analyze the gaps in knowledge level and attitude of the parents in United Arab Emirates (UAE), towards pediatric hearing loss and pediatric audiology services. The present study aimed to assess the knowledge and attitude of parents in Sharjah, UAE.A cross-sectional survey was administered to 295 parents in a tertiary care hospital setting. The self-reported questionnaire consisted of 26 items. 34.2% of the parents ascertaining good knowledge and 65.8% reported poor knowledge regarding the various factors related to the childhood hearing loss. Further, 86.2% of parents reported positive attitudes regarding accessing pediatric audiology services. A significant association was found between age groups, educational status, and knowledge levels. The study highlights the poor knowledge demonstrated by parents in the UAE regarding hearing loss and its associated risk factors. Findings outline the critical need in the region to enhance parental awareness. More health promotion activities and community outreach campaigns are necessary to increase the uptake of pediatric audiology services in the region.

7 March 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MAMuhammed Ayas
Muhammed Ayas
JMJameel Muzaffar
Jameel Muzaffar
DBDaniele Borsetto
Daniele Borsetto
SESusan Eitutis
Susan Eitutis
VPVeronica Phillips
Veronica Phillips
MBManohar Bance
Manohar Bance
Background: Extrusion of electrodes outside the cochlea and tip fold overs may lead to suboptimal outcomes in cochlear implant (CI) recipients. Intraoperative measures such as Trans-Impedance Matrix (TIM) measurements may enable clinicians to identify electrode malposition and direct surgeons to correctly place the electrode array during surgery. Objectives: To assess the current literature on the effectiveness of TIM measurements in identifying extracochlear electrodes and tip fold overs. Methods: A scoping review of studies on TIM-based measurements were carried out using the Databases-Medline/PubMed, AMED, EMBASE, CINAHL and the Cochrane Library following PRISMA guidelines. Eleven full texts articles met the inclusion criteria. Only human studies pertaining to TIM as a tool used in CI were included in the review. Further, patient characteristics, electrode design, and TIM measurement outcomes were reported. Results: TIM measurements were available for 550 implanted ears with the subjects age ranged between 9 months to 89 years. Abnormal TIM measurements were reported for 6.55% (36). Tip fold over was detected in 3.64% (20) of the cases, extracochlear electrodes in 1.45% (8), and 1.45% (8) were reported as buckling. Slim-modiolar electrode array designs were more common (54.71%) than pre-curved (23.34%) or lateral wall (21.95%) electrode array. Abnormal cochlear anatomy was reported for five ears (0.89%), with normal cochlear anatomy for all other patients. Conclusion: TIM measurement is a promising tool for the intraoperative detection of electrode malposition. TIM measurement has a potential to replace intraoperative imaging in future. Though, TIM measurement is in its early stages of clinical utility, intuitive normative data sets coupled with standardised criteria for detection of abnormal electrode positioning would enhance its sensitivity.

27 June 2021 in International Journal of Pediatrics
Verified
Journal Article
Open access
PDF file
MAMuhammed Ayas
Muhammed Ayas
HYHakam Yaseen
Hakam Yaseen
Objectives. Newborn hearing screening (NHS) plays a critical role in early identification of hearing loss and subsequent early habilitation. Active parental involvement influences the success of NHS, particularly the initial NHS and follow-up. The current study reports the results of an NHS program in a cohort of babies born in a tertiary care hospital in Sharjah, United Arab Emirates (UAE). Further, it explores a two-stage NHS model to reduce false responses, thereby alleviating parental anxiety. Methods. Retrospective observational study was conducted for a period of five years from January 2017 to December 2020. NHS was done as a two-stage model. All the healthy newborn babies were screened using Automated Auditory Brainstem Response (AABR) by trained audiology professionals. Babies who failed the first NHS were followed up after two weeks. Further, babies that failed the follow-up NHS were sent for diagnostic hearing evaluation and intervention as necessary. Results. A total of 1821 newborn babies were screened during the study period. Eighty-one percent of babies passed the initial NHS. Four hundred and twenty-three (23.22%) babies were referred on the first NHS and were followed up after 2 weeks. Among these babies, 7.03% (24) failed second NHS. Nine (37.50%) of the 24 babies were confirmed to have hearing loss in both ears. The incidence of hearing loss in our cohort was 4.94 per 1000. Confirmed hearing loss was statistically higher in boys than girls (p<0.05) Conclusion. Current study was an attempt to report the emerging NHS data as part of the implementation of an NHS program. The study findings emphasize the need for a two-stage model of NHS to rule out false responses.

20 March 2021 in Brazilian Journal of Otorhinolaryngology
Verified
Journal Article
Open access
MAMuhammed Ayas
Muhammed Ayas
AAAhmad AlAmadi
Ahmad AlAmadi
Dizziness has been reported to be the most common symptom in elderly population. Video head impulse test, VHIT, allows clinicians to assess the vestibular function in elderly individuals, during their initial stages of vestibular symptoms. Inferences from VHIT responses were traditionally low vestibulo-ocular reflex gain or a normal vestibulo-ocular reflex gain. However, the possibility of a third and new variant of the vestibulo-ocular reflex gain has not been clinically explored yet. To determine and report distinct patterns of vestibulo-ocular reflex gain using VHIT in elderly individuals with vestibular symptoms. Retrospective cross-sectional study was done on a group of elderly patients who were above 70 years of age. These individuals were subjected to VHIT during their symptomatic phase. A vestibulo-ocular reflex gain value between 0.80-01.20 (Horizontal plane) was considered normal. The gain above and below this cutoff range was considered abnormal. 39 elderly patients (15 males and 24 females) whose mean age range was 74.71 years were evaluated for the VHIT response. Vestibulo-ocular reflex gain obtained was categorized into three distinct patterns: (i) normal vestibulo-ocular reflex gain, (ii) reduced vestibulo- ocular reflex gain and (iii) increased vestibulo-ocular reflex gain. The mean vestibulo- ocular reflex gain for both left and right horizontal canals varied significantly between the three groups (p < 0.05). No significant effect of age and vestibulo-ocular reflex gain was noted, though vestibulo-ocular reflex gain was higher in 80 years and above age (p > 0.05). Elderly individuals with dizziness may show varying responses with vestibulo-ocular reflex gain during the symptomatic period. The third type of hyperactive vestibule-ocular reflex responses that emerged from the current study were potential indicators of fluid dynamic changes in the inner ear. These responses need to be explored further as it relates to new clinical markers for both peripheral and central vestibular disorders.

18 December 2023 in Cochlear Implants International
Verified
Journal Article
Closed access
RPRosalyn Fiona Parker
Rosalyn Fiona Parker
JMJameel Muzaffar
Jameel Muzaffar
MAMuhammed Ayas
Muhammed Ayas
WBWilliam Brassington
William Brassington
Device activation typically occurs four weeks post cochlear implant surgery. Emerging evidence suggests earlier activation is feasible and beneficial, giving patients quicker access to sound and rehabilitation. Assess current literature for effects of early cochlear implant activation. Electronic searches of Medline/PubMed, AMED, EMBASE, CINAHL and the Cochrane Library following PRISMA guidelines. Studies investigating any aspect of early activation were included for review. From 15 studies, 625 patients received early activation, compared with 243 patients in the control groups. Early activation was considered as within 7 days post-operatively with 12 studies reporting within 1 day post-operatively, compared with standard activation of 9-46 days post-operatively in the control group. Some studies indicated earlier low levels of impedance in the early activation group. Magnet strength adjustment or off-ear processor wear was often recommended within the early activation cohort. Complication rates were low in both groups. Early activation improved patient satisfaction and anxiety levels without detriment to speech recognition or rehabilitation. Early cochlear implant activation is feasible and allows patients with no contraindications, earlier access to auditory perception and rehabilitation and reduces anxiety linked to delay in activation. Further evidence is required to monitor long-term effects of early activation.