Rasoul Akbari

Dr. Rasoul Akbari

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2021 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
RARasoul Akbari
Rasoul Akbari
AIAfshin Izadian
Afshin Izadian
RWRobert S. Weissbach
Robert S. Weissbach
This paper introduces a new configuration of the DFIG-based wind energy conversion system (WECS) employing only a reduced-size Rotor Side Converter (RSC) in tandem with a supercapacitor. In the proposed structure, the Grid Side Converter (GSC) utilized in conventional DFIG-based WECSs is successfully eliminated. This is accomplished by employing the hydraulic transmission system (HTS) as a continuously variable and shaft decoupling transmission unit. This transforms the conventional constant-ratio drives by providing an opportunity to control the power flow through the generator's rotor circuit regardless of the wind turbine's shaft speed. This feature of HTS can be utilized to control the RSC power and ultimately regulate the supercapacitor voltage without a need for GSC. The proposed system is investigated and simulated in MATLAB Simulink at various wind speeds to validate the results and demonstrate the dynamic performance of the system.

23 August 2021 in Journal of Solar Energy Engineering
Verified
Journal Article
Closed access
PDF file
RARasoul Akbari
Rasoul Akbari
AIAfshin Izadian
Afshin Izadian
This paper introduces the modeling and control of split-shaft drivetrains where the system’s inertia is adjusted to store the energy. Accordingly, a flywheel is mechanically coupled with the rotor of a doubly fed induction generator. The generator is driven by a split-shaft drivetrain that decouples the turbine’s shaft from the shaft of the generator to provide independent control of their angular velocities. Hence, the turbine controller can track the point of maximum power while the generator controller can adjust the generator speed. Accordingly, the flywheel, which is directly connected to the shaft of the generator, is charged and discharged by controlling the generator speed. In this process, the flywheel can modify the electric power generation of the generator on-demand. Since the drivetrain is a split-shaft, the turbine speed is not affected by this energy storing process. This improves the quality of injected power to the grid. The structure of the flywheel energy storage can be simplified by removing its dedicated motor/generator and the power electronics driver. This significant modification can only occur in the split-shaft drivetrain. Two separate supervisory controllers are developed in the form of fuzzy logic regulators to generate a real-time output power reference. Furthermore, small-signal models are developed to analyze and improve the maximum power point tracking controller. Extensive simulation results demonstrate the feasibility of such a system and its improved quality of power generation.

14 April 2022 in Energies
Verified
Journal Article
Open access
PDF file
RARasoul Akbari
Rasoul Akbari
STSeyede Zahra Tajalli
Seyede Zahra Tajalli
AFAbdollah Kavousi Fard
Abdollah Kavousi Fard
AIAfshin Izadian
Afshin Izadian
This paper introduces a modified consensus-based real-time optimization framework for utility-connected and islanded microgrids scheduling in normal conditions and under cyberattacks. The exchange of power with the utility is modeled, and the operation of the microgrid energy resources is optimized to minimize the total energy cost. This framework tracks both generation and load variations to decide optimal power generations and the exchange of power with the utility. A linear cost function is defined for the utility where the rates are updated at every time interval. In addition, a realistic approach is taken to limit the power generation from renewable energy sources, including photovoltaics (PVs), wind turbines (WTs), and dispatchable distributed generators (DDGs). The maximum output power of DDGs is limited to their ramp rates. Besides this, a specific cloud-fog architecture is suggested to make the real-time operation and monitoring of the proposed method feasible for utility-connected and islanded microgrids. The cloud-fog-based framework is flexible in applying demand response (DR) programs for more efficiency of the power operation. The algorithm’s performance is examined on the 14 bus IEEE network and is compared with optimal results. Three operating scenarios are considered to model the load as light and heavy, and after denial of service (DoS) attack to indicate the algorithm’s feasibility, robustness, and proficiency. In addition, the uncertainty of the system is analyzed using the unscented transformation (UT) method. The simulation results demonstrate a robust, rapid converging rate and the capability to track the load variations due to the probable responsive loads (considering DR programs) or natural alters of load demand.

14 May 2021
Verified
Conference Paper
Closed access
RARasoul Akbari
Rasoul Akbari
AIAfshin Izadian
Afshin Izadian
Wind turbines have large inertia. However, in hydraulic wind turbine drivetrains, the displacement ratio of the hydraulic machinery reduced the inertia experienced at the generator. Restoring this inertia requires a direct connection of a large flywheel to the rotor of the generator. This paper introduces the modeling and control of such a system. The rotating mass of the storage is mechanically coupled with the rotor of a doubly-fed induction generator. The drivetrain decouples the shaft of the turbine from the shaft of the generator to provide independent control of their angular velocities. Full control over the speed of the generator and its flywheel provides a means to charge and discharge the energy storage, on-demand. Consequently, the quality of power generated by wind turbines improves as the power fluctuations, imposed by wind speed intermittencies, reduces. The structure of flywheel energy storage (FESS) can be simplified and the supporting power electronics and its dedicated motor-generator can be eliminated. Only in hydraulic drivetrain systems, such integration and save of the components is possible. Two supervisory controllers are introduced and utilized using the fuzzy logic regulator to determine the output power reference. Furthermore, small-signal analysis is provided to investigate and improve the speed of tracking the maximum power point. Extensive simulation results demonstrate the feasibility of such a system and its improved quality of power generation.

15 August 2022 in International Journal of Energy Research
Verified
Journal Article
Closed access
RARasoul Akbari
Rasoul Akbari
AIAfshin Izadian
Afshin Izadian

Verified
Journal Article
Open access
PDF file
RARasoul Akbari
Rasoul Akbari
AIAfshin Izadian
Afshin Izadian
Split-shaft wind turbines decouple the turbine’s shaft from the generator’s shaft, enabling several modifications in the drivetrain. One of the significant achievements of a split-shaft drivetrain is the reduction in size of the excitation circuit. The grid-side converter is eliminated, and the rotor-side converter can safely reduce its size to a fraction of a full-size excitation. Therefore, this low-power-rated converter operates at low voltage and handles regular operations well. However, fault conditions may expose weaknesses in the converter and push it to its limits. This paper investigates the effects of the reduced-size rotor-side converter on the voltage ride-through capabilities required from all wind turbines. Four different protection circuits, including the active crowbar, active crowbar along a resistor–inductor circuit (C-RL), series dynamic resistor (SDR), and new-bridge fault current limiter (NBFCL), are employed, and their effects are investigated and compared. Wind turbine controllers are also utilized to reduce the impact of faults on the power electronic converters. One effective method is to store excess energy in the generator’s rotor. The proposed low-voltage ride-through strategies are simulated in MATLAB Simulink (2022b) to validate the results and demonstrate their effectiveness and functionality.