Asthma is heterogeneous but accessible biomarkers to distinguish relevant phenotypes remain lacking, particularly in non-Type 2 (T2)-high asthma. Moreover, common clinical characteristics in both T2-high and T2-low asthma (e.g., atopy, obesity, inhaled steroid use) may confound interpretation of putative biomarkers and of underlying biology. This study aimed to identify volatile organic compounds (VOCs) in exhaled breath that distinguish not only asthmatic and non-asthmatic subjects, but also atopic non-asthmatic controls and also by variables that reflect clinical differences among asthmatic adults. A total of 73 participants (30 asthma, eight atopic non-asthma, and 35 non-asthma/non-atopic subjects) were recruited for this pilot study. A total of 79 breath samples were analyzed in real-time using an automated portable gas chromatography (GC) device developed in-house. GC-mass spectrometry was also used to identify the VOCs in breath. Machine learning, linear discriminant analysis, and principal component analysis were used to identify the biomarkers. Our results show that the portable GC was able to complete breath analysis in 30 min. A set of nine biomarkers distinguished asthma and non-asthma/non-atopic subjects, while sets of two and of four biomarkers, respectively, further distinguished asthmatic from atopic controls, and between atopic and non-atopic controls. Additional unique biomarkers were identified that discriminate subjects by blood eosinophil levels, obese status, inhaled corticosteroid treatment, and also acute upper respiratory illnesses within asthmatic groups. Our work demonstrates that breath VOC profiling can be a clinically accessible tool for asthma diagnosis and phenotyping. A portable GC system is a viable option for rapid assessment in asthma.
Screening methods available for colorectal cancer (CRC) to date are burdened by poor reliability and low patient adherence and compliance. An altered pattern of volatile organic compounds (VOCs) in exhaled breath has been proposed as a non-invasive potential diagnostic tool for distinguishing CRC patients from healthy controls (HC). The aim of this study was to evaluate the reliability of an innovative portable device containing a micro-gas chromatograph in enabling rapid, on-site CRC diagnosis through analysis of patients’ exhaled breath. In this prospective trial, breath samples were collected in a tertiary referral center of colorectal surgery, and analysis of the chromatograms was performed by the Biomedical Engineering Department. The breath of patients with CRC and HC was collected into Tedlar bags through a Nafion filter and mouthpiece with a one-way valve. The breath samples were analyzed by an automated portable gas chromatography device. Relevant volatile biomarkers and discriminant chromatographic peaks were identified through machine learning, linear discriminant analysis and principal component analysis. A total of 68 subjects, 36 patients affected by histologically proven CRC with no evidence of metastases and 32 HC with negative colonoscopies, were enrolled. After testing a training set (18 CRC and 18 HC) and a testing set (18 CRC and 14 HC), an overall specificity of 87.5%, sensitivity of 94.4% and accuracy of 91.2% in identifying CRC patients was found based on three VOCs. Breath biopsy may represent a promising non-invasive method of discriminating CRC patients from HC.
Retention time drift caused by fluctuations in physical factors such as temperature ramping rate and carrier gas flow rate is ubiquitous in chromatographic measurements. Proper peak matching and identification across different chromatograms is critical prior to any subsequent analysis but is challenging without using mass spectrometry. The purpose of this work was to describe and validate a peak matching and identification method called retention time trajectory (RTT) matching that can be used in targeted analyses free of mass spectrometry. This method uses chromatographic retention times as the only input and identifies peaks associated with any subset of a predefined set of target compounds. An RTT is a two-dimensional (2D) curve formed uniquely by the retention times of the chromatographic peaks. The RTTs obtained from the chromatogram of a sample under test and those pre-installed in a library are matched and statistically compared. The best matched pair implies identification. Unlike most existing peak-alignment methods, no mathematical warping or transformation is involved. Based on the experimentally characterized RTT, an RTT hybridization method was also developed to rapidly generate more RTTs and expand the library without performing actual time-consuming chromatographic measurements, which enables successful peak matching even for chromatograms with severe retention time drifts. Additionally, 3.15 × 105 tests using experimentally obtained gas chromatograms and 2 × 1012 tests using two publicly available fruit metabolomics datasets validated the proposed method, demonstrating real-time peak/interferent identification.
To ensure scientific reproducibility of metabolomics data, alternative statistical methods are needed. A paradigm shift away from the p-value toward an embracement of uncertainty and interval estimation of a metabolite’s true effect size may lead to improved study design and greater reproducibility. Multilevel Bayesian models are one approach that offer the added opportunity of incorporating imputed value uncertainty when missing data are present. We designed simulations of metabolomics data to compare multilevel Bayesian models to standard logistic regression with corrections for multiple hypothesis testing. Our simulations altered the sample size and the fraction of significant metabolites truly different between two outcome groups. We then introduced missingness to further assess model performance. Across simulations, the multilevel Bayesian approach more accurately estimated the effect size of metabolites that were significantly different between groups. Bayesian models also had greater power and mitigated the false discovery rate. In the presence of increased missing data, Bayesian models were able to accurately impute the true concentration and incorporating the uncertainty of these estimates improved overall prediction. In summary, our simulations demonstrate that a multilevel Bayesian approach accurately quantifies the estimated effect size of metabolite predictors in regression modeling, particularly in the presence of missing data.