John Scofield

Dr. John Scofield


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
JSJohn Scofield
John Scofield
SBSusannah Brodnitz
Susannah Brodnitz
JCJakob Cornell
Jakob Cornell
TLTian Liang
Tian Liang
TSThomas Scofield
Thomas Scofield
In this work, we present results from the largest study of measured, whole-building energy performance for commercial LEED-certified buildings, using 2016 energy use data that were obtained for 4417 commercial office buildings (114 million m2) from municipal energy benchmarking disclosures for 10 major U.S. cities. The properties included 551 buildings (31 million m2) that we identified as LEED-certified. Annual energy use and greenhouse gas (GHG) emission were compared between LEED and non-LEED offices on a city-by-city basis and in aggregate. In aggregate, LEED offices demonstrated 11% site energy savings but only 7% savings in source energy and GHG emission. LEED offices saved 26% in non-electric energy but demonstrated no significant savings in electric energy. LEED savings in GHG and source energy increased to 10% when compared with newer, non-LEED offices. We also compared the measured energy savings for individual buildings with their projected savings, as determined by LEED points awarded for energy optimization. This analysis uncovered minimal correlation, i.e., an R2 < 1% for New Construction (NC) and Core and Shell (CS), and 8% for Existing Euildings (EB). The total measured site energy savings for LEED-NC and LEED-CS was 11% lower than projected while the total measured source energy savings for LEED-EB was 81% lower than projected. Only LEED offices certified at the gold level demonstrated statistically significant savings in source energy and greenhouse gas emissions as compared with non-LEED offices.

1 December 2021 in Resources, Conservation and Recycling
Verified
Journal Article
Closed access
KLKaifang Luo
Kaifang Luo
JSJohn Scofield
John Scofield
YQYueming (Lucy) Qiu
Yueming (Lucy) Qiu

3 October 2018 in Journal of Exposure Science & Environmental Epidemiology
Verified
Journal Article
Open access
PDF file
JSJohn Scofield
John Scofield
JCJakob Cornell
Jakob Cornell
MacNaughton et al. recently published an article entitled, “Energy savings, emissions reductions, and health co-benefits of the green building movement” in which they claim to calculate the environmental co-benefits associated with the (assumed) reduced energy use of green buildings. They consider only LEED (Leadership in Energy and Environmental Design) commercial buildings and make two fundamental assumptions: (1) that each LEED building, year after year, achieves the energy savings projected by its design team, and (2) that the fuel mix of LEED buildings is the same as the average mix for other buildings in the same geographic region. Here we show that these assumptions are not supported by data. Numerous studies have shown that buildings, on average, use significantly more energy than projected by design simulations. Furthermore, a decade of research suggests that LEED-certified buildings, on average, achieve little or no primary energy savings relative to other similar buildings. In addition, evidence suggests that any reduction in site energy is typically achieved through increased electric use and corresponding off-site energy loss. The environmental benefits of LEED buildings calculated by MacNaughton et al. have dubious value because they are based on assumptions that are inconsistent with measured LEED building energy performance.

1 January 2022 in Journal of Building Engineering
Verified
Journal Article
Closed access
JSJohn Scofield
John Scofield