Zhiyang He

Dr. Zhiyang He

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZHZhiyang He
Zhiyang He
WCWeidong Cheng
Weidong Cheng
JXJiqiang Xia
Jiqiang Xia
WWWeigang Wen
Weigang Wen
MLMeng Li
Meng Li
With the development of industrial robots and other mechanical equipment to a higher degree of automation, mechanical systems have become increasingly complex. This represents a huge challenge for condition monitoring. The separation of vibration source signals plays an important role in condition monitoring and fault diagnosis. The key to the separation method of the vibration source signal is prior knowledge, such as of the statistical features of the vibration source signal, the number of vibration sources, and so forth. However, effective prior knowledge is difficult to obtain in engineering applications. This study found that low rank is a common feature of rotating machinery vibration source signals. To address the problem of the difficulty obtaining the signal feature of a vibration source, the multi-low-rank constrained vibration source signal separation method was proposed. Its advantages and effectiveness have been verified through simulations and experimental tests. Compared with the blind source separation method of independent component analysis (BSS-ICA) and the ensemble empirical mode decomposition (EEMD) methods, it obtained better clustering results and higher signal-to-signal ratio (SSR) values.