We propose a surface plasmon resonance (SPR) sensor based on photonic crystal fiber (PCF) with selectively filled analyte channels. Silver is used as the plasmonic material to accurately detect the analytes and is coated with a thin graphene layer to prevent oxidation. The liquid-filled cores are placed near to the metallic channel for easy excitation of free electrons to produce surface plasmon waves (SPWs). Surface plasmons along the metal surface are excited with a leaky Gaussian-like core guided mode. Numerical investigations of the fiber’s properties and sensing performance are performed using the finite element method (FEM). The proposed sensor shows maximum amplitude sensitivity of 418 Refractive Index Units (RIU−1) with resolution as high as 2.4 × 10−5 RIU. Using the wavelength interrogation method, a maximum refractive index (RI) sensitivity of 3000 nm/RIU in the sensing range of 1.46–1.49 is achieved. The proposed sensor is suitable for detecting various high RI chemicals, biochemical and organic chemical analytes. Additionally, the effects of fiber structural parameters on the properties of plasmonic excitation are investigated and optimized for sensing performance as well as reducing the sensor’s footprint.
We propose a simple, two rings, hexagonal lattice photonic crystal fiber biosensor using surface plasmon resonance phenomenon. An active plasmonic gold layer and the analyte (sample) are placed outside the fiber structure instead of inside the air-holes, which will result in a simpler and straight forward fabrication process. The proposed sensor exhibits birefringent behavior that enhances its sensitivity. Numerical investigation of the guiding properties and sensing performance are conducted by finite element method. Using wavelength and amplitude interrogation methods, the proposed sensor could provide maximum sensitivity of 4000 nm/RIU and 320 RIU -1 , respectively. The resolutions of the sensor are 2.5 × 10 -5 and 3.125 × 10 -5 RIU for wavelength and amplitude interrogation modes. The proposed sensor design shows promising results that could be used in biological and biochemical analytes detection.
We propose a photonic crystal fiber surface plasmon resonance biosensor where the plasmonic metal layer and the sensing layer are placed outside the fiber structure, which makes the sensor configuration practically simpler and the sensing process more straightforward. Considering the long-term stability of the plasmonic performance, copper (Cu) is used as the plasmonic material, and graphene is used to prevent Cu oxidation and enhance sensing performance. Numerical investigation of guiding properties and sensing performance is performed by using a finite-element method. The proposed sensor shows average wavelength interrogation sensitivity of 2000 nm/refractive index unit (RIU) over the analyte refractive indices ranging from 1.33 to 1.37, which leads to a sensor resolution of 5 × 10 -5 RIU. Due to the simple structure and promising results, the proposed sensor could be a potential candidate for detecting biomolecules, organic chemicals, and other analytes.
The fabrication process of photonic crystal fibers based on a stack-and-draw method is presented in full detail in this article. In addition, improved techniques of photonic crystal fiber preform preparation and fabrication are highlighted. A new method of connecting a handle to a preform using only a fiber drawing tower is demonstrated, which eliminates the need for a high-temperature glass working lathe. Also, a new technique of modifying the photonic crystal fiber structural pattern by sealing air holes of the photonic crystal fiber cane is presented. Using the proposed methods, several types of photonic crystal fibers are fabricated, which suggests potential for rapid photonic crystal fibers fabrication in laboratories equipped with and limited to only a fiber drawing tower.
The distributed fibre sensing technology based on backward stimulated Brillouin scattering (BSBS) is experiencing a rapid development. However, all reported implementations of distributed Brillouin fibre sensors until today are restricted to detecting physical parameters inside the fibre core. On the contrary, forward stimulated Brillouin scattering (FSBS), due to its resonating transverse acoustic waves, is being studied recently to facilitate innovative detections in the fibre surroundings, opening sensing domains that are impossible with BSBS. Nevertheless, due to the co-propagating behaviour of the pump and scattered lights, it is a challenge to position-resolve FSBS information along a fibre. Here we show a distributed FSBS analysis based on recovering the FSBS induced phase change of the propagating light waves. A spatial resolution of 15 m is achieved over a length of 730 m and the local acoustic impedances of water and ethanol in a 30 m-long uncoated fibre segment are measured, agreeing well with the standard values.
The standard single-mode fiber has been demonstrated as an optomechanical sensor recently to measure the acoustic impedances of surrounding liquids by means of the generation and detection of forward-stimulated Brillouin scattering (FSBS). FSBS allows the mechanical properties of an external material to be probed directly through the interaction of guided light and transverse sound waves that occurs entirely inside the fiber structure. In this technique, having a low-loss interface between the fiber bulk and the external medium is essential for precise measurement; however, it leads to the necessary but impractical removal of the thick polymer fiber coating in most reported methods. Here, we use a commercially available 80-μm-diameter optical fiber coated with a 8-μm-thick polyimide coating layer to measure the acoustic impedances of the surrounding liquids, showing accurate measurement results while retaining the mechanical strength of the fiber.