BACKGROUND: The cryoballoon (CB) represents the gold standard single-shot device for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Single-shot pulsed field PVI ablation (nonthermal, cardiac tissue selective) has recently entered the arena. We sought to compare procedural data and long-term outcome of both techniques. METHODS: Consecutive AF patients who underwent pulsed field ablation (PFA) and CB-based PVI were enrolled. CB PVI was performed using the second-generation 28-mm CB; PFA was performed using a 31/35-mm pentaspline catheter. Success was defined as freedom from atrial tachyarrhythmia after a 3-month blanking period. RESULTS: Four hundred patients were included (56.5% men; 60.8% paroxysmal AF; age 70 [interquartile range, 59–77] years), 200 in each group (CB and PFA), and baseline characteristics did not differ. Acute PVI was achieved in 100% of PFA and in 98% (196/200) of CB patients ( P =0.123; 4 touch-up ablations). Median procedure time was significantly shorter in PFA (34.5 [29–40] minutes) versus CB (50 [45–60] minutes; P <0.001), fluoroscopy time was similar. Overall procedural complications were 6.5% in CB and 3.0% in PFA ( P =0.1), driven by a higher rate of phrenic nerve palsies using CB. The 1-year success rates in paroxysmal AF (CB, 83.1%; PFA, 80.3%; P =0.724) and persistent AF (CB, 71%; PFA, 66.8%; P =0.629) were similar for both techniques. CONCLUSIONS: PFA compared with CB PVI shows a similar procedural efficacy but is associated with shorter procedure time and no phrenic nerve palsies. Importantly, 12-month clinical success rates are favorable but not different between both groups.
Kawasaki disease (KD), also known as mucocutaneous lymph node syndrome, is an acute systemic vasculitis with unexplained causes, affecting mainly infants and children. Since its first description in Japan in l967 by Tomisaku Kawasaki, KD has been increasingly reported worldwide.1,2
6 October 2019 in Journal of Cardiovascular Electrophysiology
Fish oil is rich in unsaturated fatty acids, i.e., eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA), both of which are widely distributed in the body such as heart and brain. In vivo and in vitro experiments showed that unsaturated fatty acids may have effects of anti-inflammation, anti-oxidation, protecting vascular endothelial cells, thrombosis inhibition, modifying autonomic nerve function, improving left ventricular remodeling, and regulating blood lipid. Given the relevance to public health, there has been increasing interest in the research of potential cardioprotective effects of fish oil. Accumulated evidence showed that fish oil supplementation may reduce the risk of cardiovascular events, and, in specific, it may have potential benefits in improving the prognosis of patients with hypertension, coronary heart disease, cardiac arrhythmias, or heart failure; however, some studies yielded inconsistent results. In this article, we performed an updated systematical review in order to provide a contemporary understanding with regard to the effects of fish oil on cardiovascular diseases.
1 February 2021 in Circulation: Arrhythmia and Electrophysiology
Background: Pulmonary vein isolation (PVI) represents the cornerstone in atrial fibrillation ablation. Cryoballoon and laserballoon catheters have emerged as promising devices but lack randomized comparisons. Therefore, we sought to compare efficacy and safety comparing both balloons in patients with persistent and paroxysmal atrial fibrillation (AF). Methods: Symptomatic AF patients (n=200) were prospectively randomized (1:1) to receive either cryoballoon or laserballoon PVI (cryoballoon: n=100: 50 paroxysmal atrial fibrillation + 50 persistent AF versus laserballoon: n=100: 50 paroxysmal atrial fibrillation + 50 persistent AF). All antiarrhythmic drugs were stopped after ablation. Follow-up included 3-day Holter-ECG recordings and office visits at 3, 6, and 12 months. Primary efficacy end point was defined as freedom from atrial tachyarrhythmia between 90 and 365 days after a single ablation. Secondary end points included procedural parameters and periprocedural complications. Results: Patient baseline parameters were not different between both groups. In all (n=200) complete PVI was obtained and the entire follow-up accomplished. Balloon only PVI was obtained in 98% (cryoballoon) versus 95% (laserballoon) requiring focal touch-up in 2 and 5 patients, respectively. Procedure but not fluoroscopy time was significantly shorter in the cryoballoon group (50.9±21.0 versus 96.0±20.4 minutes; P <0.0001 and 7.4±4.4 versus 8.4±3.2 minutes, P =0.083). Overall, the primary end point of no atrial tachyarrhythmia recurrence was met in 79% (cryoballoon: 80.0% versus laserballoon: 78.0%, P =ns). No death, atrio-esophageal fistula, tamponade, or vascular laceration requiring surgery occurred. In the cryoballoon group, 8 transient but no persistent phrenic nerve palsy were noted compared with 2 persistent phrenic nerve palsy and one transient ischemic attack in the laserballoon group. Conclusions: Both balloon technologies represent highly effective and safe tools for PVI resulting in similar favorable rhythm outcome after 12 months. Use of the cryoballoon is associated with significantly shorter procedure but not fluoroscopy time.