Zhengqi Wang

Dr. Zhengqi Wang

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
ZWZhengqi Wang
Zhengqi Wang
HZHaoyu Zhou
Haoyu Zhou
HSHongyu Su
Hongyu Su
This paper presents a disturbance observer-based model predictive of super-twisting control for Soft Open Point (SOP). First, with the consideration of the disturbances caused by parameter mismatches and unmodelled dynamics, a super-twisting sliding-mode observer (STO) is proposed to observe the disturbances, and the observed disturbances are introduced into the inner-loop as the compensation to improve the anti-disturbance of SOP system. Second, the outer-loop controller is designed by applying the super-twisting sliding-mode control (STC) approach to improve the dynamic performance and robustness. Third, to deal with large current harmonics by traditional model predictive control (MPC), a Three-Vector-based MPC (TV-MPC) is proposed to increase the number of voltage vectors in a sampling time. Finally, it is verified by simulations that the proposed method can reduce current harmonics, DC-side voltage setting time and improve the dynamic performance of SOP system effectively. In case of parameter mismatches, the proposed observer can observe the disturbances correctly to enhance the robustness of the SOP system.

29 June 2021 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
ZWZhengqi Wang
Zhengqi Wang
LSLiusen Sheng
Liusen Sheng
QHQunhai Huo
Qunhai Huo
SHSipeng Hao
Sipeng Hao
Soft open point (SOP) is a key power electronic device to improve the flexibility and stability of the distribution network and is becoming a research hotspot. The traditional double closed-loop control of SOP has a complex structure, difficult process of parameter design, and poor output power quality. To solve these problems, finite control set model predictive control (FCS-MPC) has been adopted. Since FCS-MPC involves a large amount of calculation and experiences delay in current tracking, an improved FCS-MPC with delay compensation is proposed for three-port SOP in this paper to replace the inner loop current control strategy. Improved model predictive control combines the two-step prediction method based on the voltage vector and vector angle compensation method. The vector method is used to construct a mathematical model and a prediction model of three-port SOP. Based on FCS-MPC, the two-step prediction method that takes voltage as the target is used to compensate for the current delay problem, and the amount of calculation is reduced by converting the control target. Meanwhile, the vector angle compensation method is used to compensate the future reference value. Finally, a simulation model is built in MATLAB/Simulink. The simulation results under steady state and dynamic conditions show that the proposed strategy can effectively improve the current delay and reduce the amount of calculation. Furthermore, it has better current tracking accuracy and faster dynamic response speed.

5 January 2022 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
ZWZhengqi Wang
Zhengqi Wang
HZHaoyu Zhou
Haoyu Zhou
QHQunhai Huo
Qunhai Huo
SHSipeng Hao
Sipeng Hao
Soft open point (SOP) can improve the flexibility and reliability of power supplies; thus, they are widely used in distribution network systems. Traditional single-vector model predictive control (SV-MPC) can quickly and flexibly control the power and current at both ports of the SOP. However, SV-MPC can only select one voltage vector in a sampling time, producing large current ripples, and power fluctuations. In order to solve the above problems, this paper proposes a three-vector-based low complexity model predictive control (TV-MPC). In the proposed control method, two effective voltage vectors and one zero voltage vector are selected in a sampling time. For the two-port SOP, methods are given to judge the sectors on both sides and select the voltage vectors. Furthermore, the calculation method of the distribution time is proposed as well. Finally, the effectiveness of the proposed method is verified by steady-state and dynamic-state simulation results compared with the SV-MPC.