An efficient and sensitive analytical method based on high-performance anion exchange chromatography with pulsed amperometric detection (HPAEC-PAD) was established for the simultaneous separation and determination of glucosamine (GlcN)1 and chitooligosaccharides (COS) ranging from (GlcN)2 to (GlcN)6 without prior derivatization. Detection limits were 0.003 to 0.016 mg/L (corresponding to 0.4–0.6 pmol), and the linear range was 0.2 to 10 mg/L. The optimized analysis was carried out on a CarboPac-PA100 analytical column (4 × 250 mm) using isocratic elution with 0.2 M aqueous sodium hydroxide-water mixture (10:90, v/v) as the mobile phase at a 0.4 mL/min flow rate. Regression equations revealed a good linear relationship (R2 = 0.9979–0.9995, n = 7) within the test ranges. Quality parameters, including precision and accuracy, were fully validated and found to be satisfactory. The fully validated HPAEC-PAD method was readily applied for the quantification of (GlcN)1–6 in a commercial COS technical concentrate. The established method was also used to monitor the acid hydrolysis of a COS technical concentrate to ensure optimization of reaction conditions and minimization of (GlcN)1 degradation.
Chitooligosaccharides (COSs) are a promising drug candidate and food ingredient because they are innately biocompatible, non-toxic, and non-allergenic to living tissues. Therefore, the impurities in COSs must be clearly elucidated and precisely determined. As for COSs, most analytical methods focus on the determination of the average degrees of polymerization (DPs) and deacetylation (DD), as well as separation and analysis of the single COSs with different DPs. However, little is known about the concentrations of inorganic cations and anions in COSs. In the present study, an efficient and sensitive ion chromatography coupled with conductivity detection (IC-CD) for the determination of inorganic cations Na+, NH4+, K+, Mg2+, Ca2+, and chloride, acetate and lactate anions was developed. Detection limits were 0.01–0.05 μM for cations and 0.5–0.6 μM for anions. The linear range was 0.001–0.8 mM. The optimized analysis was carried out on IonPac CS12A and IonPac AS12A analytical column for cations and anions, respectively, using isocratic elution with 20 mM methanesulfonic acid and 4 mM sodium hydroxide aqueous solution as the mobile phase at a 1.0 mL/min flow rate. Quality parameters, including precision and accuracy, were fully validated and found to be satisfactory. The fully validated IC-CD method was readily applied for the quantification of various cations and anions in commercial COS technical concentrate.
Point mutation G143A in the cytochrome b (Cyt b) protein commonly confers resistance to quinone outside inhibitor (QoI) fungicides in phytopathogenic fungi, including Corynespora cassiicola, which causes cucumber target spot disease. However, the effect of G143A on the binding between the QoI fungicide and the Cyt b protein, and the use of LAMP (loop-mediated isothermal amplification) to detect this point mutation had not been reported previously in C. cassiicola. In this study, the sensitivity of 131 C. cassiicola isolates—collected from Shandong province, China in 2019 and 2020—to pyraclostrobin was determined. The EC50 values ranged from 1.67 to 8.82 μg/mL, and sequencing results showed that all C. cassiicola isolates contained the G143A mutation. Molecular docking results suggested that G143A significantly alters the affinity of pyraclostrobin to the Cyt b protein. Following development of three LAMP primer pairs, the best reaction condition for LAMP analysis was 65 °C for 60 min, and the detection limit was 0.01 ng/μL of DNA containing the point mutation. In conclusion, the G143A mutation conferring pyraclostrobin resistance is widespread in C. cassiicola from Shandong province, and the LAMP method can be used to monitor QoI resistance in C. cassiicola caused by the G143A mutation in the field.