Zhi FANG

Prof. Zhi FANG


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in Composites Part B: Engineering
Verified
Journal Article
Closed access
LLLuming Liu
Luming Liu
ZFZhi FANG
Zhi FANG
ZHZhengyu Huang
Zhengyu Huang
YWYu-You Wu
Yu-You Wu

3 November 2020 in Advances in Structural Engineering
Verified
Journal Article
Closed access
PDF file
RHRui Hu
Rui Hu
ZFZhi FANG
Zhi FANG
CSCaijun Shi
Caijun Shi
BBBrahim Benmokrane
Brahim Benmokrane
JSJie Su
Jie Su
Ultra-high performance concrete (UHPC) is a type of cementitious composite, and demonstrates very high compressive strength and good ductility. The favorable ductility and energy dissipation capacity of UHPC material make it possible to achieve excellent seismic performance in all kinds of structural members. The paper reviewed the recent progress on the seismic behavior of UHPC members, including flexural members (beams and plates), compressive members (columns and shear walls), joints (beam-column joints and plate-column joints), strengthening (strengthening for columns, shear walls and joints) and connections (bar lap splice and grout). A series of potential future researches on the seismic behavior of UHPC members were finally suggested for promotion of the application of UHPC in civil engineering.

1 August 2015 in Journal of Composites for Construction
Verified
Journal Article
Closed access
KZKuangyi Zhang
Kuangyi Zhang
ZFZhi FANG
Zhi FANG
ANAntonio Nanni
Antonio Nanni
JHJianhua Hu
Jianhua Hu
GCGuoping Chen
Guoping Chen
The poor performance and durability of traditional steel tendon and cement grout have become serious constraints to the development of ground anchor systems, especially when these systems are permanent features in large-scale projects such as ground anchors with capacities of more than 4,000 kN in Aizhai Bridge, China. This paper presents a large-scale ground anchor system with carbon fiber-reinforced polymer (CFRP) tendon and reactive powder concrete (RPC) grout as the bonding media in both above-ground and below-ground parts. Two full-scale ground anchor specimens named GA12-20 and GA12-9 were designed and installed at the construction site, and their behavior was systematically studied through monotonic and cyclic load testing. The two systems displayed acceptable displacements under both monotonic load testing with maximum tension twice the design lock-off load and in cyclic load testing under about 90% of its bearing capacity, with residual displacements all less than 5 mm. Furthermore, the bond stress distributions in the grouted portions of the rods in tendon showed both systems have reliable bonding capacities under tension. This innovative ground anchor system with CFRP tendon and RPC grout showed a good behavior and successfully served as the ground anchor of the Aizhai Bridge.

1 October 2019 in Journal of Composites for Construction
Verified
Journal Article
Closed access
YFYawei Fang
Yawei Fang
ZFZhi FANG
Zhi FANG
RJRuinian Jiang
Ruinian Jiang
YXYu Xiang
Yu Xiang
DHDaobin Huang
Daobin Huang

1 October 2016 in Journal of Structural Engineering
Verified
Journal Article
Closed access
KZKuangyi Zhang
Kuangyi Zhang
ZFZhi FANG
Zhi FANG
ANAntonio Nanni
Antonio Nanni
Research works related to the fiber-reinforced polymer (FRP) tendons have focused on the anchor system, but the anchor is not the only contribution to performance. Since civil structures require tendons consisting of multiple rods (e.g., cables, suspenders in bridges, or rock bolts in ground anchors), the characteristics of multirod tendons require targeted research. This paper presents a study on the behavior of tendons with multiple carbon FRP (CFRP) rods. Four specimens including two cable-type assemblies (TA12-9 and TA12-20) and two ground anchors (GA12-9 and GA12-20) with large-tonnage capacities were built and tested. Using strain gauges set along individual rods, the nonuniform force distribution among individual rods was observed and is discussed. The test results showed that nonuniformity is a recurring feature of a multirod tendon, with the variation in the initial length of the rods caused by installation error as its main reason. Based on the premise that tension in multiple rods obeys...

1 September 2010 in International Journal of Structural Stability and Dynamics
Verified
Journal Article
Closed access
XYXinfeng Yin
Xinfeng Yin
SCSteve Cai
Steve Cai
ZFZhi FANG
Zhi FANG
LDLu Deng
Lu Deng