Yonny Romaguera Barcelay

Dr. Yonny Romaguera Barcelay

Chemical Engineering Department/BioMark@UC, Universidade de Coimbra, Coimbra, Portugal
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2014 in Thin Solid Films
Verified
Journal Article
Closed access
Yonny Romaguera BarcelayYonny Romaguera Barcelay
Yonny Romaguera Barcelay
Joaquim Agostinho MoreiraJoaquim Agostinho Moreira
Joaquim Agostinho Moreira
AAA. Almeida
A. Almeida
Pedro B. TavaresPedro B. Tavares
Pedro B. Tavares
JCJ. Pérez de la Cruz
J. Pérez de la Cruz

25 February 2015 in Science and Technology of Advanced Materials
Verified
Journal Article
Open access
HAHarvey Amorín
Harvey Amorín
MAMiguel Algueró
Miguel Algueró
RCRubén Del Campo
Rubén Del Campo
EVEladio Vila
Eladio Vila
PSPablo Ramos Sainz
Pablo Ramos Sainz
ACAlicia Castro
Alicia Castro
A highly topical set of perovskite oxides are high-sensitivity piezoelectric ones, among which Pb(Zr,Ti)O3 at the morphotropic phase boundary (MPB) between ferroelectric rhombohedral and tetragonal...

7 May 2012 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
ATA. Tkach
A. Tkach
AAA. Almeida
A. Almeida
Joaquim Agostinho MoreiraJoaquim Agostinho Moreira
Joaquim Agostinho Moreira
JCJ. Perez de la Cruz
J. Perez de la Cruz
Yonny Romaguera BarcelayYonny Romaguera Barcelay
Yonny Romaguera Barcelay
PVPaula Maria Vilarinho
Paula Maria Vilarinho
In this work, NaTaO3 ceramics are prepared by conventional mixed oxide method and NaTaO3 films are deposited by RF magnetron sputtering on Si/SiO2/TiO2/Pt substrates. The dielectric response of the obtained NaTaO3 ceramics and films is analyzed as a function of frequency and temperature. Between 1 kHz and 1 MHz, the dielectric permittivity of NaTaO3 ceramics is frequency independent and increases on cooling up to ∼324, which is the highest value ever reported for NaTaO3 ceramics. In contrast, NaTaO3 films exhibit a dielectric relaxation between ∼20 and 30 K, following the Arrhenius law with activation energy ∼51 meV and pre-exponential term ∼10−15 s and attributed to polaron hopping.

1 March 2012 in Materials Letters
Verified
Journal Article
Closed access
Yonny Romaguera BarcelayYonny Romaguera Barcelay
Yonny Romaguera Barcelay
Joaquim Agostinho MoreiraJoaquim Agostinho Moreira
Joaquim Agostinho Moreira
AAA. Almeida
A. Almeida
JAJoão Esteves Araújo
João Esteves Araújo
JCJ. Pérez de la Cruz
J. Pérez de la Cruz

13 January 2011 in Journal of Electroceramics
Verified
Journal Article
Closed access
PDF file
Yonny Romaguera BarcelayYonny Romaguera Barcelay
Yonny Romaguera Barcelay
Joaquim Agostinho MoreiraJoaquim Agostinho Moreira
Joaquim Agostinho Moreira
GGG. González-Aguilar
G. González-Aguilar
AAA. Almeida
A. Almeida
JAJoão Esteves Araújo
João Esteves Araújo
JCJavier Pérez De La Cruz
Javier Pérez De La Cruz

10 May 2024 in RSC Advances
Verified
Journal Article
Open access
PDF file
DODaniela Oliveira
Daniela Oliveira
Yonny Romaguera BarcelayYonny Romaguera Barcelay
Yonny Romaguera Barcelay
Felismina T.C. MoreiraFelismina T.C. Moreira
Felismina T.C. Moreira
In this study, a molecularly imprinted polymer film (MIP) was prepared on the surface of a disposable carbon screen-printed electrode (C-SPE) using (3-acrylamidopropyl)trimethylammonium chloride (AMPTMA) as a functional monomer and the cancer biomarker carbohydrate antigen 15-3 (CA 15-3) as a template. The MIP was synthesized by in situ electropolymerization (ELP) of the AMPTMA monomer in the presence of the CA 15-3 protein on the C-SPE surface. The target was subsequently removed from the polymer matrix by the action of proteinase K, resulting in imprinted cavities with a high affinity for CA 15-3. Electrochemical techniques such as cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to characterize the different phases of the sensor assembly. Chemical and morphological analysis was performed using RAMAN and scanning electron microscopy (SEM). CA 15-3 was successfully detected in a wide working range from 0.001 U mL−1 to 100 U mL−1 with a correlation coefficient (R2) of 0.994 in 20 min. The MIP sensor showed minimal interference with other cancer proteins (CEA and CA 125). Overall, the developed device provides a rapid, sensitive, and cost-effective response in the detection of CA 15-3. Importantly, this comprehensive approach appears suitable for point-of-care (PoC) use, particularly in a clinical context.