Lahoucine Ouhsaine

Dr. Lahoucine Ouhsaine

University of Lorraine/LERMAB-Longwy team, IUT Henri Poincaré
+1

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2018 in Building Simulation
Verified
Journal Article
Closed access
PDF file
YKYassine Kharbouch
Yassine Kharbouch
Lahoucine OuhsaineLahoucine Ouhsaine
Lahoucine Ouhsaine
AMAbdelaziz Mimet
Abdelaziz Mimet
MGMohammed El Ganaoui
Mohammed El Ganaoui

1 March 2020 in Journal of Building Engineering
Verified
Journal Article
Closed access
FMFaiza Mnasri
Faiza Mnasri
SBSofiane Bahria
Sofiane Bahria
Mohamed El-Amine SlimaniMohamed El-Amine Slimani
Mohamed El-Amine Slimani
Lahoucine OuhsaineLahoucine Ouhsaine
Lahoucine Ouhsaine
MGMohammed El Ganaoui
Mohammed El Ganaoui

17 August 2017 in International Journal of Sustainable Energy
Verified
Journal Article
Closed access
YKYassine Kharbouch
Yassine Kharbouch
AMAbdelaziz Mimet
Abdelaziz Mimet
MGMohammed El Ganaoui
Mohammed El Ganaoui
Lahoucine OuhsaineLahoucine Ouhsaine
Lahoucine Ouhsaine

1 December 2017 in Energy Procedia
Verified
Journal Article
Open access
Lahoucine OuhsaineLahoucine Ouhsaine
Lahoucine Ouhsaine
YBYassine Boukal
Yassine Boukal
MGMohammed El Ganaoui
Mohammed El Ganaoui
MDMohammed Darouach
Mohammed Darouach
MZMichel Zasadzinski
Michel Zasadzinski
NRNour Eddine Radhy
Nour Eddine Radhy

1 October 2014
Verified
Conference Paper
Closed access
Lahoucine OuhsaineLahoucine Ouhsaine
Lahoucine Ouhsaine
AMAbdelaziz Mimet
Abdelaziz Mimet
MGMohammed El Ganaoui
Mohammed El Ganaoui
ASAngel Scipioni
Angel Scipioni
YKYassine Kharbouch
Yassine Kharbouch
The mono-crystalline photovoltaic cells are very sensitive to the ambient temperature despite the high conversion efficiency compared to other low-temperature solar cells. To enhance its efficiency we analyse of the Photovoltaic cells under conjugate heat and mass transfer for the active cooling within hot areas climates integration. The major objective of this study was to predict within 2D simulation the heat transfer behaviour of the materials then to optimize the geometry of heat exchanger depending on specified control parameters. Results show that the performance of using mini-channels heat sinks is significant in matter of thermal dissipation and low pressure drops, and the PV efficiency should increase for 8 % relatively to the standard efficiency, but in appropriate design and limitations.

29 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
Lahoucine OuhsaineLahoucine Ouhsaine
Lahoucine Ouhsaine
El ganaoui MohammedEl ganaoui Mohammed
El ganaoui Mohammed
AMAbdelaziz Mimet
Abdelaziz Mimet
Jean-Michel NunziJean-Michel Nunzi
Jean-Michel Nunzi
A modelling approach based on the Substitutive Coefficients Network (SCN) is developed to predict the thermal behavior of a system in the dynamic state-space, without requiring knowledge of the thermal mass. The method can apply either to large- (building, combined solar systems, geothermal energy, and thermodynamic installations) or to small-scale systems (heat exchangers, electronic devices cooling systems, and Li-ion batteries). This current method is based on a dimensionless formulation of the simplified dynamic thermal balance model, using relaxation time as a key parameter to establish the model. The introduction of relaxation time reduces the parameters set as guidance coefficients. The parameters are finally expressed by a combination of global heat transfer coefficients related to each layer and/or sub-layer of the system. Advantages of the method are reliability, “non-destructibility”, i.e., it allows a reliable prediction of the thermal behavior which experimentally is inaccessible, and reducibility of the parameters size estimate. Additionally, the method is inexpensive in terms of computation memory. It is also easy to implement in practical numerical schemes. In this paper, the method leads to a simplified mathematical model that predicts the thermal behavior of a mono-zone eco-cottage building installed at Lorraine University (in Longwy, France) as a case study. Thermal performance of the building is estimated under the hourly weather conditions onsite, as obtained from the Meteonorm software. The thermal dynamics within hourly Typical Meteorological Year 2 (TMY2) Meteonorm data disturbances and the internal heating input state in the winter period were simulated with a simplified numerical discretization method. Results provide a general dynamic state of the different sub-components of the system, with limited design of the model parameters.