Yuri Pisarevsky

Dr. Yuri Pisarevsky

Shubnikov Institute of Crystallography of Federal Scientific Research Centre “Crystallography and Photonics” of Russian Academy of Sciences, 59, Leninsky pr., 119333 Moscow, Russia

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2017 in Acta Crystallographica Section D Structural Biology
Verified
Journal Article
Closed access
PDF file
ABAnastasiia Boikova
Anastasiia Boikova
YDYulia A. Dyakova
Yulia A. Dyakova
KIKseniia B. Ilina
Kseniia B. Ilina
PKPeter Konarev
Peter Konarev
AKAlyona E. Kryukova
Alyona E. Kryukova
MKMikhail V. Kovalchuk
Mikhail V. Kovalchuk

31 May 2021 in Materials
Verified
Journal Article
Open access
PDF file
VBVladislav Batshev
Vladislav Batshev
AMAlexander S. Machikhin
Alexander S. Machikhin
AGAlexey Gorevoy
Alexey Gorevoy
GMGrigoriy Martynov
Grigoriy Martynov
DKDemid Khokhlov
Demid Khokhlov
Yuri PisarevskyYuri Pisarevsky
Yuri Pisarevsky
Spectral image filtration by means of acousto-optical tunable filters (AOTFs) has multiple applications. For its implementation, a few different optical schemes are in use. They differ in image quality, number of coupling components, dimensions and alignment complexity. To choose the optical system of AOTF-based spectral imager properly, many factors have to be considered. Though various schemes of acousto-optic (AO) filtration have been tested and discussed, their comparative analysis has not been reported up to now. In this study, we assembled the four most popular schemes (confocal, collimating, tandem and double-path) using the same AO cells and experimentally compared their main features. Depending on the application, each scheme may be the basis of compact cost-effective spectral imaging devices.

1 January 2019 in Crystallography Reports
Verified
Journal Article
Closed access
PDF file
MKM. V. Kovalchuk
M. V. Kovalchuk
OAO. A. Alekseeva
O. A. Alekseeva
ABA. E. Blagov
A. E. Blagov
GIG. D. Ilyushin
G. D. Ilyushin
KIK. B. Il’INa
K. B. Il’INa
GPG. S. Peters
G. S. Peters
The potassium dihydrogen phosphate K(H2PO4) (KDP) cluster structures formed in aqueous solutions have been theoretically and experimentally investigated. Cluster modeling of the...

8 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
VBVladislav Batshev
Vladislav Batshev
AMAlexander S. Machikhin
Alexander S. Machikhin
GMGrigoriy Martynov
Grigoriy Martynov
VPVitold Eduard. Pozhar
Vitold Eduard. Pozhar
SBSergey Boritko
Sergey Boritko
AVAlexander Vinogradov
Alexander Vinogradov
Optical biomedical imaging in short wave infrared (SWIR) range within 0.9–1.7 μm is a rapidly developing technique. For this reason, there is an increasing interest in cost-effective and robust hardware for hyperspectral imaging data acquisition in this range. Tunable-filter-based solutions are of particular interest as they provide image processing flexibility and effectiveness in terms of collected data volume. Acousto-optical tunable filters (AOTFs) provide a unique set of features necessary for high-quality SWIR hyperspectral imaging. In this paper, we discuss a polarizer-free configuration of an imaging AOTF that provides a compact and easy-to-integrate design of the whole imager. We have carried out image quality analysis of this system, assembled it and validated its efficiency through multiple experiments. The developed system can be helpful in many hyperspectral applications including biomedical analyses.

1 April 2023 in Journal of Applied Crystallography
Verified
Journal Article
Closed access
PDF file
PGPolina Gureva
Polina Gureva
AKAnton Kulikov
Anton Kulikov
AMAnatoliy Mololkin
Anatoliy Mololkin
RFRashid Fakhrtdinov
Rashid Fakhrtdinov
AAAlex Artemev
Alex Artemev
NMNikita Marchenkov
Nikita Marchenkov

16 January 2024 in Optics
Verified
Journal Article
Open access
PDF file
NMNikita Marchenkov
Nikita Marchenkov
EMEvgenii Mareev
Evgenii Mareev
AKAnton Kulikov
Anton Kulikov
FPFedor Pilyak
Fedor Pilyak
EIEduard Ibragimov
Eduard Ibragimov
FPFedor Potemkin
Fedor Potemkin
The synchronization of laser and X-ray sources is essential for time-resolved measurements in the study of ultrafast processes, including photo-induced piezo-effects, shock wave generation, and phase transitions. On the one hand, optical diagnostics (by synchronization of two laser sources) provides information about changes in vibration frequencies, shock wave dynamics, and linear and nonlinear refractive index behavior. On the other hand, optical pump–X-ray probe diagnostics provide an opportunity to directly reveal lattice dynamics. To integrate two approaches into a unified whole, one needs to create a robust method for the synchronization of two systems with different repetition rates up to the MHz range. In this paper, we propose a universal approach utilizing a field-programmable gate array (FPGA) to achieve precise synchronization between different MHz sources such as various lasers and synchrotron X-ray sources. This synchronization method offers numerous advantages, such as high flexibility, fast response, and low jitter. Experimental results demonstrate the successful synchronization of two different MHz systems with a temporal resolution of 250 ps. This enables ultrafast measurements with a sub-nanosecond resolution, facilitating the uncovering of complex dynamics in ultrafast processes.