Debo Li

Dr. Debo Li


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2021 in Processes
Verified
Journal Article
Open access
PDF file
DLDebo Li
Debo Li
NZNing Zhao
Ning Zhao
YFYongxin Feng
Yongxin Feng
ZXZhiwen Xie
Zhiwen Xie
For coal semi-char as a by-produced of low-temperature pyrolysis, combustion for power generation is one of the effective utilization methods to realize its clean and efficient utilization. However, the coal semi-char combustion process has a difficult ignition, unstable combustion and low burnout rate. The co-firing of the semi-char with biomass under oxy-fuel conditions can improve the combustion behavior and reduce fossil CO2 emissions. In this paper, the combustion behavior of Shenhua coal semi-char (SHC) co-firing with straw (ST) in O2/CO2 mixture is investigated using thermogravimetric analysis. The results show that each curve lays between those of the individual fuels and presents three peaks (i.e., three stages). The thermogravimetric curves of SHC co-firing with ST can be divided into three stages: the volatile combustion of ST, the co-combustion of SHC and ST fixed-carbons and the SHC fixed-carbon combustion and the decomposition of the difficult pyrolytic material of ST. Blending ST into the SHC can significantly decrease the ignition temperature and improve the comprehensive combustion behavior of blended samples. In increasing the proportion of ST from 25 to 100%, the change of the blended ignition temperature is slight, but the burnout temperature decreases greatly. Kinetic parameters of combustion are calculated by using the Coats–Redfern integral method. Compared to that of stage I and stage III, the activation energy of stage II is significantly lower. As increasing blending ratio from 25% to 100%, the activation energy increases at stage I and decreases at stage III. Furthermore, the O2 concentration obviously affects stage III of 50% SHC + 50% ST, and the thermogravimetric curves at this stage are obviously shifted to the lower temperature zone as the O2 concentration increases. The activation energy of 50% SHC + 50% ST increases as the oxygen concentration increases. Besides, the activation energy shows that the combustion characteristics cannot be determined only by the activation energy obtained by the Coats–Redfern method. These findings can provide useful information for semi-char co-firing with biomass.

14 February 2022 in Asia-Pacific Journal of Chemical Engineering
Verified
Journal Article
Closed access
PDF file
DLDebo Li
Debo Li
YFYongxin Feng
Yongxin Feng
ZCZhihao Chen
Zhihao Chen
ZCZhaoli Chen
Zhaoli Chen
HHHanyan He
Hanyan He
ZYZhaosheng Yu
Zhaosheng Yu

12 July 2021 in Coatings
Verified
Journal Article
Open access
PDF file
NZNing Zhao
Ning Zhao
YFYongxin Feng
Yongxin Feng
DLDebo Li
Debo Li
ZLZongkun Li
Zongkun Li
As an advanced treatment of desulfurization wastewater, centrifugal spray drying technology, which can achieve a zero liquid discharge target, has attracted wide attention and great interest in recent years. However, the results of previous studies were based on the laboratory-scale centrifugal spray dryer. In order to study the evaporation characteristics of desulfurization wastewater and the parameter optimization of the dryer, the evaporation model of wastewater droplets was established. The effects of parameters such as the angle of the deflectors, gas–liquid ratio and atomizer speed on droplet evaporation were studied by numerical simulation. The results show that with the increase in the angle of the deflectors, the swirl effect of flue gas flow field is more obvious and the time and axial distance required for the complete evaporation of the droplets are shorter. Reducing the gas–liquid ratio will make the average evaporation time longer. Moreover, a higher atomizer speed is helpful for the evaporation of the droplets. The optimum gas–liquid ratio and rotational speed are found to be 9300 m3/Nm3 and 16,000 rpm, respectively.

26 August 2021 in Coatings
Verified
Journal Article
Open access
PDF file
DLDebo Li
Debo Li
NZNing Zhao
Ning Zhao
YFYongxin Feng
Yongxin Feng
ZXZhiwen Xie
Zhiwen Xie
The desulfurization wastewater evaporation technology with flue gas has been widely applied to dispose of desulfurization wastewater. This paper investigates the effect of flue gas flow rate and temperature, wastewater flow rate and initial temperature, and droplet size on the evaporation performance of the desulfurization wastewater in a spray drying tower without deflectors. The results show that the flue gas flow rate and temperature affect the evaporation performance of desulfurization wastewater. The larger flow rate and higher temperature of flue gas correspond to the faster evaporation speed and the shorter complete evaporation distance of the wastewater droplet. Decreasing the flow rate and increasing the initial temperature of the desulfurization wastewater is advantageous to enhance the evaporation speed and shorten the complete evaporation distance of the wastewater droplet. Reducing the droplet size is beneficial to improve the evaporation performance of the desulfurization wastewater. The orthogonal test results show that the factors affecting droplet evaporation performance are ranked as follows: flue gas flow rate > wastewater flow rate > flue gas temperature > wastewater initial temperature > droplet size. Considering the evaporation ratio and the complete evaporation distance, the optimal setting is 14.470 kg/s for flue gas flow rate, 385 °C for flue gas temperature, 0.582 kg/s for wastewater flow rate, 25 °C for wastewater initial temperature, and 60 μm for droplet size. These studied results can provide valuable information to improve the operational performance of the desulfurization wastewater evaporation technology with flue gas.

7 January 2022 in Water
Verified
Journal Article
Open access
PDF file
NZNing Zhao
Ning Zhao
YFYongxin Feng
Yongxin Feng
DLDebo Li
Debo Li
LCLimei Chen
Limei Chen
With the improvement of environmental protection requirements, more and more attention has been given to desulphurization wastewater with zero discharge in coal power plants. Atomization drying is part of the main zero discharge technologies at present. Economic analysis of the atomization drying of desulphurization wastewater is beneficial to the formulation of an appropriate operation scheme and to the reduction of operation costs. The economic analysis and sensitivity analysis of different operating conditions such as unit load, the handling capacity of concentrates, and the temperature of the extracted flue gas in the atomization drying process of concentrated desulfurized wastewater were carried out in this paper. The main cost of the drying process came from the influence of flue gas extraction on the overall heat transfer in the boiler, resulting in the decrease in power generation revenue, which can reach more than 80%. The operating cost of auxiliary machinery was relatively low. The cost of treatment for per ton of concentrates increased first and then decreased with the increase in temperature of the extracted flue gas, and it decreased with the increase in the handling capacity of the concentrates. The effect of a unit load on the treatment cost was also related to the temperature of the extracted flue gas, and the optimal flue gas temperature increase to higher temperatures as the unit load decreased. The minimum treatment costs per ton of concentrate ranged from CNY 143.54/t to CNY 158.77/t under different unit loads. Sensitivity analysis showed that the temperature of the extracted flue gas had the greatest impact on treatment cost, and its sensitivity coefficient was 0.0834. The ways in which to improve economic benefits were discussed.

1 March 2017
Verified
Conference Paper
Closed access
DLDebo Li
Debo Li
YFYongxin Feng
Yongxin Feng
JZJun Zhong
Jun Zhong
JZJielian Zhou
Jielian Zhou
LYLibao Yin
Libao Yin
JZJunhao Zhou
Junhao Zhou
This paper aims to tackle the shortcomings of the standard artificial bee colony algorithm (ABC) such as slow convergence, long solving time and being easy to fall into local optima. We study the state transformation formula and propose a parallelized ABC algorithm with Message Passing Interface (MPI). We use the traveling salesman problem (TSP) as the case study. Our experiments show that the parallel ABC algorithm has an advantage in speed over the standard algorithm w.r.t. iterations and convergence speed.