Stefania Sabella

Dr. Stefania Sabella

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in Particle and Fibre Toxicology
Verified
Journal Article
Open access
PDF file
VSVicki Stone
Vicki Stone
SPStefano Pozzi-Mucelli
Stefano Pozzi-Mucelli
LTLang Tran
Lang Tran
KAKarin Aschberger
Karin Aschberger
SSStefania Sabella
Stefania Sabella
JSJaneck J. Scott-Fordsmand
Janeck J. Scott-Fordsmand
To assess the risk of all nanomaterials (NMs) on a case-by-case basis is challenging in terms of financial, ethical and time resources. Instead a more intelligent approach to knowledge gain and risk assessment is required.

9 February 2017 in Nanoscale
Verified
Journal Article
Open access
PDF file
PBPasquale Bove
Pasquale Bove
MMMaria Ada Malvindi
Maria Ada Malvindi
SKSachin Sayaji Kote
Sachin Sayaji Kote
Rosalia BertorelliRosalia Bertorelli
Rosalia Bertorelli
MSMaria Summa
Maria Summa
SSStefania Sabella
Stefania Sabella
Worldwide efforts are currently trying to produce effective risk assessment models for orally ingested nanoparticles. These tests should provide quantitative information on the bioaccessibility and bioavailability of products of biotransformation, such as dissolved ionic species and/or aggregates. In vitro dissolution tests might be useful for nanoparticle risk assessment, because of their potential to quantitatively monitor the changes of specific properties (e.g., dissolution, agglomeration, etc.), which are critical factors linked to bioaccessibility/bioavailability. Unfortunately, the technological advancement of such tools is currently hampered by the complexity and evolving nature of nanoparticle properties that are strongly influenced by the environment and are often difficult to trace in a standardized manner. Hence, the test's success depends on its ability to quantify such properties using standardized experimental conditions to mimic reality as closely as possible. Here we applied an in vitro dissolution test to quantify the dissolution of silver nanoparticles under dynamic conditions, which likely occur in human digestion, providing a clear description of the bioaccessible ionic species (free and matrix bound ions or soluble silver organic or inorganic complexes) occurring during the different digestion phases. We demonstrated the test feasibility using a multi-technique approach and following pre-standardized operational procedures to allow for a comprehensive description of the process as a whole. Moreover, this can favour data reliability for benchmarking. Finally, we showed how the estimated values of the bioaccessible ionic species relate to absorption and excretion parameters, as measured in vivo. The outcomes presented in this work highlight the potential regulatory role of the dissolution test for orally ingested nanoparticles and, although preliminary, experimentally demonstrate the regulatory oriented “read-across” principle.

2 October 2019 in Nanoscale Advances
Verified
Journal Article
Open access
PDF file
ASAnitha Senthamizhan
Anitha Senthamizhan
Despina FragouliDespina Fragouli
Despina Fragouli
BBBrabu Balusamy
Brabu Balusamy
BPBhushan Patil
Bhushan Patil
MPMilan Palei
Milan Palei
AAAthanassia Athanassiou
Athanassia Athanassiou
Smart, stimuli-responsive, photoluminescent materials that undergo a visually perceptible emission color change in the presence of an external stimulus have long been attractive for use in sensor platforms. When the stimulus is the presence of water, the materials that undergo changes in their light emission properties are called hydrochromic and they can be used for the development of sensors to detect and quantify the water content in organic solvents, which is fundamental for laboratory safety and numerous industrial applications. Herein, we demonstrate the preparation of structurally different carbon dots with tunable emission wavelengths via a simple carbonization approach under controlled temperature and time, involving commercial brown sugar as a starting material. The detailed experimental analysis reveals the “structure-hydrochromic property” relationship of the carbon dots and assesses their capability as effective water sensors. The carbon dots that were proved most efficient for the specific application were then used to identify the presence of water in various aprotic and protic organic solvents via a sensing mechanism based either on the fluorescence wavelength shift or on the fluorescence intensity enhancement, respectively, attributed to the formation of intermolecular hydrogen bonds between carbon dots and water molecules. This is the first demonstration of structurally defined carbon dots in a specific application. The developed carbon dots, apart from being environmentally friendly, were proved to also be biocompatible, enabling this presented process to be a path to “green” sensors.

18 October 2012 in Discover Nano
Verified
Journal Article
Open access
PDF file
LRLoris Rizzello
Loris Rizzello
AGAntonio Galeone
Antonio Galeone
GVGiuseppe Vecchio
Giuseppe Vecchio
VBVirgilio Brunetti
Virgilio Brunetti
SSStefania Sabella
Stefania Sabella
Pier Paolo PompaPier Paolo Pompa
Pier Paolo Pompa
Bacterial adhesion onto abiotic surfaces is an important issue in biology and medicine since understanding the bases of such interaction represents a crucial aspect in the design of safe implant devices with intrinsic antibacterial characteristics. In this framework, we investigated the effects of nanostructured metal substrates on Escherichia coli adhesion and adaptation in order to understand the bio-molecular dynamics ruling the interactions at the interface. In particular, we show how highly controlled nanostructured gold substrates impact the bacterial behavior in terms of morphological changes and lead to modifications in the expression profile of several genes, which are crucially involved in the stress response and fimbrial synthesis. These results mainly demonstrate that E. coli cells are able to sense even slight changes in surface nanotopography and to actively respond by activating stress-related pathways. At the same time, our findings highlight the possibility of designing nanoengineered substrates able to trigger specific bio-molecular effects, thus opening the perspective of smartly tuning bacterial behavior by biomaterial design.

14 May 2018 in Small
Verified
Journal Article
Closed access
PDF file
DGDaniela Guarnieri
Daniela Guarnieri
PMPAOLA SANCHEZ MORENO
PAOLA SANCHEZ MORENO
ACAntonio Esaú Del Rio Castillo
Antonio Esaú Del Rio Castillo
FBFrancesco Bonaccorso
Francesco Bonaccorso
FGFrancesca Gatto
Francesca Gatto
Pier Paolo PompaPier Paolo Pompa
Pier Paolo Pompa

29 December 2020 in Nanotoxicology
Verified
Journal Article
Closed access
CUCinzia Lucia Ursini
Cinzia Lucia Ursini
AFAnna Maria Fresegna
Anna Maria Fresegna
ACAureliano Ciervo
Aureliano Ciervo
RMRaffaele Maiello
Raffaele Maiello
VFValentina Del Frate
Valentina Del Frate
DCDelia Cavallo
Delia Cavallo
The available biomonitoring studies on workers producing/handling nanomaterials (NMs) focused on potential effects on respiratory, immune and cardio-vascular system. Aim of this study was to identify a panel of sensitive biomarkers and suitable biological matrices to evaluate particularly genotoxic and oxidative effects induced on workers unintentionally exposed to graphene or silica nanoparticles during the production process. These nanomaterials have been chosen for ‘NanoKey’ project, integrating the workplace exposure assessment (reported in part I) with the biomonitoring of exposed workers reported in the present work. Simultaneously to workplace exposure characterization, we monitored the workers using: Buccal Micronucleus Cytome (BMCyt) assay, fpg-comet test (lymphocytes), oxidized DNA bases 8-oxoGua, 8-oxoGuo and 8-oxodGuo measurements (urine), analysis of oxidative stress biomarkers in exhaled breath condensate (EBC), FENO measurement and cytokines release detection (serum). Since buccal cells are among the main targets of NM occupational exposure, particular attention was posed to the BMCyt assay that represents a noninvasive assay. This pilot study, performed on 12 workers vs.11 controls, demonstrates that BMCyt and fpg-comet assays are the most sensitive biomarkers of early, still reparable, genotoxic and oxidative effects. The findings suggest that these biomarkers could represent useful tools for the biomonitoring of workers exposed to nanoparticles, but they need to be confirmed on a high number of subjects. However, such biomarkers don’t discriminate the effects of NM from those due to other chemicals used in the NM production process. Therefore, they could be suitable for the biomonitoring of workers exposed to complex scenario, including nanoparticles exposure.