Naruto Miyakawa

Mr. Naruto Miyakawa

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
NMNaruto Miyakawa
Naruto Miyakawa
ASAyumi Shinagawa
Ayumi Shinagawa
YKYasuko Kajiwara
Yasuko Kajiwara
SUShota Ushiba
Shota Ushiba
TOTakao Ono
Takao Ono
KMKazuhiko Matsumoto
Kazuhiko Matsumoto
Solution-gated graphene field-effect transistors (SG-GFETs) provide an ideal platform for sensing biomolecules owing to their high electron/hole mobilities and 2D nature. However, the transfer curve often drifts in an electrolyte solution during measurements, making it difficult to accurately estimate the analyte concentration. One possible reason for this drift is that p-doping of GFETs is gradually countered by cations in the solution, because the cations can permeate into the polymer residue and/or between graphene and SiO2 substrates. Therefore, we propose doping sufficient cations to counter p-doping of GFETs prior to the measurements. For the pre-treatment, GFETs were immersed in a 15 mM sodium chloride aqueous solution for 25 h. The pretreated GFETs showed that the charge neutrality point (CNP) drifted by less than 3 mV during 1 h of measurement in a phosphate buffer, while the non-treated GFETs showed that the CNP was severely drifted by approximately 50 mV, demonstrating a 96% reduction of the drift by the pre-treatment. X-ray photoelectron spectroscopy analysis revealed the accumulation of sodium ions in the GFETs through pre-treatment. Our method is useful for suppressing drift, thus allowing accurate estimation of the target analyte concentration.

14 October 2022 in Applied Physics Express
Verified
Journal Article
Closed access
SUShota Ushiba
Shota Ushiba
TNTomomi Nakano
Tomomi Nakano
NMNaruto Miyakawa
Naruto Miyakawa
ASAyumi Shinagawa
Ayumi Shinagawa
TOTakao Ono
Takao Ono
KMKazuhiko Matsumoto
Kazuhiko Matsumoto
The interfacial adhesion energy between graphene and underlying substrates is considerably important for robust graphene biosensors because water molecules can intercalate underneath graphene when submerged, possibly detaching graphene from substrates. This study investigated the robustness of graphene field-effect transistor arrays fabricated on hydrophobic and hydrophilic SiO2 substrates. Although the graphene sheets delaminated from hydrophilic substrates within minutes of submersion in a buffer solution, they remained stable on hydrophobic substrates for several days. This result agreed with the estimated thermodynamic work of adhesion in water, which improved significantly from −17.3 to 17.7 mJ m−2 through the hydrophobization process of the substrates.

3 November 2023 in Microchemical Journal
Verified
Journal Article
Closed access
NMNaruto Miyakawa
Naruto Miyakawa
ASAyumi Shinagawa
Ayumi Shinagawa
TNTomomi Nakano
Tomomi Nakano
SUShota Ushiba
Shota Ushiba
TOTakao Ono
Takao Ono
KMKazuhiko Matsumoto
Kazuhiko Matsumoto

7 March 2023 in ChemRxiv
Verified
Preprint
Open access
PDF file
SUShota Ushiba
Shota Ushiba
TNTomomi Nakano
Tomomi Nakano
ASAyumi Shinagawa
Ayumi Shinagawa
NMNaruto Miyakawa
Naruto Miyakawa
TKTadashi Kato
Tadashi Kato
KMKazuhiko Matsumoto
Kazuhiko Matsumoto
In field-effect transistor (FET) biosensors, charge screening in electrolyte solutions limits sensitivity, thereby restricting the applicability of FET sensors. This is particularly pronounced in graphene FET (GFET) biosensors, where the bare graphene surface possesses a strongly negative charge, which impedes the high sensitivity of GFETs owing to nonlinear electrolytic screening at the interfaces between graphene and liquid. In this study, we counteracted the negative surface charge of graphene by decorating positively charged compounds and demonstrated the sensing of C-reactive protein (CRP) with surface-charge-modulated GFETs (SCM-GFETs). We integrated multiple SCM-GFETs with anti-CRP antibodies and non-functionalized GFETs into a chip, and measured differentials to eliminate background changes to improve measurement reliability. The FET response corresponded to the fluorescence images, which visualized the specific adsorption of CRP. The estimated dissociation constant was consistent with previously reported values; this supports the conclusion that the results are attributed to specific adsorption. Conversely, the signal in GFETs without decoration was obscured by noise because of nonlinear electrolytic screening, further emphasizing the significance of surface-charge modulation. The limit of detection (LOD) of the system was determined to be 2.9 nM. This value has the potential to be improved through further optimization of the surface charges to align with specific applications. Our devices effectively circumvent nonlinear electrolytic screening, opening the door for further advancements in GFET biosensor technology.