Roxana Sirli

Prof. Dr. Roxana Sirli

Department of Gastroenterology, "Victor Babes" University of Medicine and Pharmacy of Timisoara, Timisoara, Romania
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2013 in Liver International
Verified
Journal Article
Open access
PDF file
SBSimona Bota
Simona Bota
HHHarald Herkner
Harald Herkner
ISIoan Sporea
Ioan Sporea
PSPetra Salzl
Petra Salzl
Roxana SirliRoxana Sirli
Roxana Sirli
MPMarkus Peck‐Radosavljevic
Markus Peck‐Radosavljevic
Aims: This meta‐analysis aims to compare the diagnostic performance of acoustic radiation force impulse (ARFI) elastography and transient elastography (TE) in the assessment of liver fibrosis using liver biopsy (LB) as ‘gold‐standard’.Methods: PubMed, Medline, Lilacs, Scopus, Ovid, EMBASE, Cochrane and Medscape databases were searched for all studies published until 31 May 2012 that evaluated the liver stiffness by means of ARFI, TE and LB. Information abstracted from each study according to a fixed protocol included study design and methodological characteristics, patient characteristics, interventions, outcomes and missing outcome data.Results: Thirteen studies (11 full‐length articles and 2 abstracts) including 1163 patients with chronic hepatopathies were included in the analysis. Inability to obtain reliable measurements was more than thrice as high for TE as that of ARFI (6.6% vs. 2.1%, P < 0.001). For detection of significant fibrosis, (F ≥ 2) the summary sensitivity (Se) was 0.74 (95% CI: 0.66–0.80) and specificity (Sp) was 0.83 (95% CI: 0.75–0.89) for ARFI, while for TE the Se was 0.78 (95% CI: 0.72–0.83) and Sp was 0.84 (95% CI: 0.75–0.90). For the diagnosis of cirrhosis, the summary Se was 0.87 (95% CI: 0.79–0.92) and Sp was 0.87 (95% CI: 0.81–0.91) for ARFI elastography, and, respectively, 0.89 (95% CI: 0.80–0.94) and 0.87 (95% CI: 0.82–0.91) for TE. The diagnostic odds ratio of ARFI and TE did not differ significantly in the detection of significant fibrosis [mean difference in rDOR = 0.27 (95% CI: 0.69–0.14)] and cirrhosis [mean difference in rDOR = 0.12 (95% CI: 0.29–0.52)].Conclusion: Acoustic radiation force impulse elastography seems to be a good method for assessing liver fibrosis, and shows higher rate of reliable measurements and similar predictive value to TE for significant fibrosis and cirrhosis.

1 December 2012 in European Journal of Radiology
Verified
Journal Article
Closed access
Ioan SporeaIoan Sporea
Ioan Sporea
SBSimona Bota
Simona Bota
MPMarkus Peck-Radosavljevic
Markus Peck-Radosavljevic
Roxana SirliRoxana Sirli
Roxana Sirli
HTHironori Tanaka
Hironori Tanaka
MDMirela Danila
Mirela Danila

1 July 2012 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
SBSimona Bota
Simona Bota
ISIoan Sporea
Ioan Sporea
Roxana SirliRoxana Sirli
Roxana Sirli
APAlina Popescu
Alina Popescu
MDMirela Danila
Mirela Danila
DCDan Costachescu
Dan Costachescu

1 January 2008 in World Journal of Gastroenterology
Verified
Journal Article
Open access
ISIoan Sporea
Ioan Sporea
APAlina Popescu
Alina Popescu
Roxana SirliRoxana Sirli
Roxana Sirli
Why, who and how should perform liver biopsy in chronic liver diseases

1 November 2013 in Ultrasound in Medicine & Biology
Verified
Journal Article
Open access
Ioan SporeaIoan Sporea
Ioan Sporea
SBSimona Bota
Simona Bota
AJAna Jurchis
Ana Jurchis
Roxana SirliRoxana Sirli
Roxana Sirli
OGOana Grădinaru-Tascău
Oana Grădinaru-Tascău
MSMilana Szilaski
Milana Szilaski
Our study compared three elastographic methods--transient elastography (TE), acoustic radiation force impulse (ARFI) imaging and supersonic shear imaging (SSI)--with respect to the feasibility of their use in liver fibrosis evaluation. We also compared the performance of ARFI imaging and SSI, with TE as the reference method. The study included 332 patients, with or without hepatopathies, in which liver stiffness was evaluated using TE, ARFI and SSI. Reliable measurements were defined as a median value of 10 (TE, ARFI imaging) or 5 (SSI) liver stiffness measurements with a success rate ≥60% and an interquartile range interval <30%. A significantly higher percentage of reliable measurements were obtained using ARFI than by using TE and SSI: 92.1% versus 72.2% (p < 0.0001) and 92.1% versus 71.3% (p < 0.0001). Higher body mass index and older age were significantly associated with inability to obtain reliable measurements of liver stiffness using TE and SSI. In 55.4% of patients, reliable liver stiffness measurements were obtained using all three elastographic methods, and ARFI imaging and TE were similarly accurate in diagnosing significant fibrosis and cirrhosis, with TE as the reference method.