Anton Bukatin

Dr. Anton Bukatin

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2017 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
STStanislav Terekhov
Stanislav Terekhov
ISIvan V. Smirnov
Ivan V. Smirnov
ASAnastasiya V. Stepanova
Anastasiya V. Stepanova
TBTatyana V. Bobik
Tatyana V. Bobik
YMYuliana Mokrushina
Yuliana Mokrushina
SASidney Altman
Sidney Altman
Ultrahigh-throughput screening (uHTS) techniques can identify unique functionality from millions of variants. To mimic the natural selection mechanisms that occur by compartmentalization in vivo, we developed a technique based on single-cell encapsulation in droplets of a monodisperse microfluidic double water-in-oil-in-water emulsion (MDE). Biocompatible MDE enables in-droplet cultivation of different living species. The combination of droplet-generating machinery with FACS followed by next-generation sequencing and liquid chromatography-mass spectrometry analysis of the secretomes of encapsulated organisms yielded detailed genotype/phenotype descriptions. This platform was probed with uHTS for biocatalysts anchored to yeast with enrichment close to the theoretically calculated limit and cell-to-cell interactions. MDE–FACS allowed the identification of human butyrylcholinesterase mutants that undergo self-reactivation after inhibition by the organophosphorus agent paraoxon. The versatility of the platform allowed the identification of bacteria, including slow-growing oral microbiota species that suppress the growth of a common pathogen, Staphylococcus aureus, and predicted which genera were associated with inhibitory activity. Significance Biocompatible microfluidic double water-in-oil-in-water emulsion (MDE) enables in-droplet cultivation of different living species. The combination of droplet-generating machinery with FACS followed by next-generation sequencing and liquid chromatography-mass spectrometry analysis of the secretomes of encapsulated organisms yielded detailed genotype/phenotype descriptions. The MDE–FACS platform we developed enabled highly sensitive single-cell selection of predesigned activity and exploration of pairwise interactions between target and effector cells without interference from other microbiota species.

10 December 2015 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
ABAnton Bukatin
Anton Bukatin
IKIgor Kukhtevich
Igor Kukhtevich
NSNorbert Stoop
Norbert Stoop
JDJörn Dunkel
Jörn Dunkel
VKVasily Kantsler
Vasily Kantsler
Significance: Successful sperm navigation is essential for sexual reproduction, yet we still understand relatively little about how sperm cells are able to adapt their swimming motion in response to chemical and physical cues. This lack of knowledge is owed to the fact that it has been difficult to observe directly the full 3D dynamics of the whip-like flagellum that propels the cell through the fluid. To overcome this deficiency, we apply a new algorithm to reconstruct the 3D beat patterns of human sperm cells in experiments under varying flow conditions. Our analysis reveals that the swimming strokes of human sperm are considerably more complex than previously thought, and that sperm may use their heads as rudders to turn right or left.

22 April 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KBK. I. Belousov
K. I. Belousov
NFN. A. Filatov
N. A. Filatov
IKI. V. Kukhtevich
I. V. Kukhtevich
VKV. Kantsler
V. Kantsler
AEA. A. Evstrapov
A. A. Evstrapov
ABAnton Bukatin
Anton Bukatin
Nowadays droplet microfluidics is widely used to perform high throughput assays and for the synthesis of micro- and nanoparticles. These applications usually require packaging several reagents into droplets and their mixing to start a biochemical reaction. For rapid mixing microfluidic devices usually require additional functional elements that make their designs more complex. Here we perform a series of 2D numerical simulations, followed by experimental studies, and introduce a novel asymmetric flow-focusing droplet generator, which enhances mixing during droplet formation due to a 2D or 3D asymmetric vortex, located in the droplet formation area of the microfluidic device. Our results suggest that 2D numerical simulations can be used for qualitative analysis of two-phase flows and droplet generation process in quasi-two-dimensional devices, while the relative simplicity of such simulations allows them to be easily applied to fairly complicated microfluidic geometries. Mixing inside droplets formed in the asymmetric generator occurs up to six times faster than in a conventional symmetric one. The best mixing efficiency is achieved in a specific range of droplet volumes, which can be changed by scaling the geometry of the device. Thus, the droplet generator suggested here can significantly simplify designs of microfluidic devices because it enables both the droplet formation and fast mixing of the reagents within droplets. Moreover, it can be used to precisely estimate reaction kinetics.

23 December 2020 in Biology
Verified
Journal Article
Open access
PDF file
VBViktor Bairamukov
Viktor Bairamukov
ABAnton Bukatin
Anton Bukatin
SLSergey Landa
Sergey Landa
VBVladimir Burdakov
Vladimir Burdakov
TSTatiana Shtam
Tatiana Shtam
MSMaria Starodubtseva
Maria Starodubtseva
While extracellular vesicles (EVs) are extensively studied by various practical applications in biomedicine, there is still little information on their biomechanical properties due to their nanoscale size. We identified isolated blood plasma vesicles that carried on biomarkers associated with exosomes and exomeres and applied atomic force microscopy (AFM) to study them at single particle level in air and in liquid. Air measurements of exosomes revealed a mechanically indented internal cavity in which highly adhesive sites were located. In contrast, the highly adhesive sites of exomeres were located at the periphery and the observed diameter of the particles was ~35 nm. In liquid, the reversible deformation of the internal cavity of exosomes was observed and a slightly deformed lipid bi-layer was identified. In contrast, exomeres were not deformed and their observed diameter was ~16 nm. The difference in diameters might be associated with a higher sorption of water film in air. The parameters we revealed correlated with the well-known structure and function for exosomes and were observed for exomeres for the first time. Our data provide a new insight into the biomechanical properties of nanoparticles and positioned AFM as an exclusive source of in situ information about their biophysical characteristics.

31 January 2023 in Biology
Verified
Journal Article
Open access
PDF file
ESElisaveta Skverchinskaya
Elisaveta Skverchinskaya
NLNadezhda Andreevna Levdarovich
Nadezhda Andreevna Levdarovich
AIAlexander Ivanov
Alexander Ivanov
Igor MindukshevIgor Mindukshev
Igor Mindukshev
ABAnton Bukatin
Anton Bukatin
Red blood cells (RBCs) are the most numerous cells in the body and perform gas exchange between all tissues. During the infusion of cancer chemotherapeutic (CT) agents, blood cells are the first ones to encounter aggressive cytostatics. Erythrocyte dysfunction caused by direct cytotoxic damage might be a part of the problem of chemotherapy-induced anemia—one of the most frequent side effects. The aim of the current study is to evaluate the functional status of RBCs exposed to mono and combinations of widely used commercial pharmaceutical CT drugs with different action mechanisms: paclitaxel, carboplatin, cyclophosphamide, and doxorubicin, in vitro. Using laser diffraction, flow cytometry, and confocal microscopy, we show that paclitaxel, having a directed effect on cytoskeleton proteins, by itself and in combination with carboplatin, caused the most marked abnormalities—loss of control of volume regulation, resistance to osmotic load, and stomatocytosis. Direct simulations of RBCs’ microcirculation in microfluidic channels showed both the appearance of a subpopulation of cells with impaired velocity (slow damaged cells) and an increased number of cases of occlusions. In contrast to paclitaxel, such drugs as carboplatin, cyclophosphamide, and doxorubicin, whose main target in cancer cells is DNA, showed significantly less cytotoxicity to erythrocytes in short-term exposure. However, the combination of drugs had an additive effect. While the obtained results should be confirmed in in vivo models, one can envisioned that such data could be used for minimizing anemia side effects during cancer chemotherapy.

19 October 2016 in Technical Physics
Verified
Journal Article
Closed access
PDF file
ABAnton Bukatin
Anton Bukatin
IMIvan Mukhin
Ivan Mukhin
EME. I. Malyshev
E. I. Malyshev
IKI. V. Kukhtevich
I. V. Kukhtevich
AEA. A. Evstrapov
A. A. Evstrapov
MDMichael Dubina
Michael Dubina