Erik Spoor

Mr. Erik Spoor

CeMOS, Mannheim University of Applied Sciences, Mannheim, Baden-Württemberg, Germany
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Erik SpoorErik Spoor
Erik Spoor
VOViktoria Oerke
Viktoria Oerke
Matthias RaedleMatthias Raedle
Matthias Raedle
JRJens-Uwe Repke
Jens-Uwe Repke
In this paper, a dispersion of glass beads of different sizes in an ammonium nitrate solution is investigated with the aid of Raman spectroscopy. The signal losses caused by the dispersion are quantified by an additional scattered light measurement and used to correct the measured ammonium nitrate concentration. Each individual glass bead represents an interface at which the excitation laser is deflected from its direction causing distortion in the received Raman signal. It is shown that the scattering losses measured with the scattered light probe correlate with the loss of the Raman signal, which means that the data obtained can be used to correct the measured values. The resulting correction function considers different particle sizes in the range of 2–99 µm as well as ammonium nitrate concentrations of 0–20 wt% and delivers an RMSEP of 1.952 wt%. This correction provides easier process access to dispersions that were previously difficult or impossible to measure.

5 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Erik SpoorErik Spoor
Erik Spoor
Matthias RaedleMatthias Raedle
Matthias Raedle
JRJens-Uwe Repke
Jens-Uwe Repke
In the present study, the influence of disperse systems on Raman scattering was investigated. How an increasing particle concentration weakens the quantitative signal of the Raman spectrum is shown. Furthermore, the change in the position of the optimal measurement point in the fluid was considered in detail. Additional transmission measurements can be used to derive a simple and robust correction method that allows the actual concentration of the continuous phase to be determined with a standard deviation of 2.6%.

22 October 2024 in Chemie Ingenieur Technik
Verified
Journal Article
Open access
Erik SpoorErik Spoor
Erik Spoor
SMSteffen Manser
Steffen Manser
OMOliver Mandal
Oliver Mandal
MBMelanie Bruch
Melanie Bruch
FNFranz‐Josef Nagler
Franz‐Josef Nagler
MRMatthias Rädle
Matthias Rädle
A custom‐made Raman setup is improved and adjusted to allow its use in Ex zones by using a 1‐mW laser and no optical focusing elements. The application under consideration is the hydroformylation of decene to undecanal, which must take place under explosion protection. To investigate the dispersive mixture, a separation takes place in a phase separation cell in which the Raman probe performs measurements. It can be shown that, with the use of highly sensitive detectors, even very low excitation powers can lead to a processable signal, and thus the application of Raman measurement technology far below the requirements of explosion protection is possible.

1 March 2023 in Reactions
Verified
Journal Article
Open access
PDF file
Erik SpoorErik Spoor
Erik Spoor
SWStefan Welzel
Stefan Welzel
Ulrich NiekenUlrich Nieken
Ulrich Nieken
Matthias RaedleMatthias Raedle
Matthias Raedle
With the goal to better process the monitoring of occurring fouling, a backscatter probe was developed to perform in-line measurements in a half-shell reactor during the reaction of N-vinylpyrrolidone (NVP) to polyvinylpyrrolidone (PVP). The measurement technique detects the changes of bands in the UV range, which allows a direct correlation with the concentration. Thus, the measured absorbance signal allows a conclusion on the accumulation of fouling in the reactor and on changes in the conversion at the measurement location.

15 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SMSteffen Manser
Steffen Manser
SKSandy Kommert
Sandy Kommert
SKShaun Keck
Shaun Keck
Erik SpoorErik Spoor
Erik Spoor
Matthias RaedleMatthias Raedle
Matthias Raedle
Quality control and reaction monitoring are necessary to ensure the consistency of any kind of mixing or reaction process. In this context, a novel portable high-sensitivity sensor prototype based on the Raman effect is presented in this study. The elongated probe head is designed for (but not limited to) monitoring high temperature batch processes for quality assurance. Thanks to the highly sensitive special detectors, concentration differences of up to 50 mmol/L can currently be detected, which facilitates compliance with high product quality standards. In addition, seamless reaction tracking is possible. Small individual adjustments through simple, intuitive mechanical components provide a high degree of flexibility in reaction selection by the end user. Specially developed software automates the evaluation process and gives the user visual signals about the current status and progress of the batch as well as an emergency stop if temperature limits could damage individual components. By using all the individual components developed, the problem of the limited integration times of previous spectrometric measuring instruments could be reduced. The prototype was validated using concentration measurements of various substances that occur as standard in batch processes. In addition, this article provides an outlook on the fact that Raman measurements can also be carried out successfully and reliably in explosive environments in the future with the prototype presented.

1 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SCShivani Choudhary
Shivani Choudhary
Deborah HerdtDeborah Herdt
Deborah Herdt
Erik SpoorErik Spoor
Erik Spoor
JMJosé Fernando García Molina
José Fernando García Molina
MNMarcel Nachtmann
Marcel Nachtmann
Matthias RaedleMatthias Raedle
Matthias Raedle
To meet the demands of the chemical and pharmaceutical process industry for a combination of high measurement accuracy, product selectivity, and low cost of ownership, the existing measurement and evaluation methods have to be further developed. This paper demonstrates the attempt to combine future Raman photometers with promising evaluation methods. As part of the investigations presented here, a new and easy-to-use evaluation method based on a self-learning algorithm is presented. This method can be applied to various measurement methods and is carried out here using an example of a Raman spectrometer system and an alcohol-water mixture as demonstration fluid. The spectra’s chosen bands can be later transformed to low priced and even more robust Raman photometers. The evaluation method gives more precise results than the evaluation through classical methods like one primarily used in the software package Unscrambler. This technique increases the accuracy of detection and proves the concept of Raman process monitoring for determining concentrations. In the example of alcohol/water, the computation time is less, and it can be applied to continuous column monitoring.