Jing Yang

Dr. Jing Yang


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2010 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Closed access
PDF file
Jing YangJing Yang
Jing Yang
XQXiushu Qie
Xiushu Qie
GZGuangshu Zhang
Guangshu Zhang
QZQilin Zhang
Qilin Zhang
GFGuili Feng
Guili Feng
RJRubin Jiang
Rubin Jiang

31 July 2021 in Remote Sensing
Verified
Journal Article
Open access
PDF file
DCDongjie Cao
Dongjie Cao
FLFeng Lu
Feng Lu
XZXiaohu Zhang
Xiaohu Zhang
Jing YangJing Yang
Jing Yang
The Lightning Mapping Imager (LMI) onboard the geostationary meteorological satelliteFengYun-4A (FY-4A) detects both intra-cloud (IC) and cloud-to-ground (CG) lightning continuously during daytime and nighttime. This study examined, for the first time, the optical characteristics and distribution of the “Event,” “Group,” and “Flash” observed by the LMI in the whole LMI observation domain. The optical properties and spatial distribution of the LMI lightning were compared with those of the Lightning Imaging Sensor on the International Space Station (ISS-LIS) based on the dataset during 2018–2020. Due to the different spatial resolutions and detection efficiencies of these two lightning imagers, the number of ISS-LIS lightning was more than that of LMI lightning. The ISS-LIS Flash duration was also larger than that of the LMI Flash. The duration, radiance, and footprint of LMI lightning in different regions were analyzed in detail based on the LMI lightning dataset in 2019. The duration and radiance of the Flash were generally less than 50–500 ms and 200 Jm−2ster−1μm−1, respectively. The footprint of Flashes was distributed from 200 to 600 km2. The number of Groups per Flash was mostly less than five. Considering the spatial distribution and temporal variations in the LMI lightning compared with the ground-based Lightning Location Network in China (LLNC), it was found that the LMI Group number was close to the LLNC CG (Cloud-to-Ground) Event number. The maximum Flash density was found in the middle and lower south of the Yangtze River and Pearl River Delta region, respectively, while the lower values were in western China, where the mean radiance per Flash was greater. There was more LMI lightning during the nighttime than that during the daytime, indicating the higher detection efficiency of the LMI in the nighttime than in the daytime.

30 April 2021 in Remote Sensing
Verified
Journal Article
Open access
PDF file
ZCZhixiong Chen
Zhixiong Chen
XQXiushu Qie
Xiushu Qie
JSJuanzhen Sun
Juanzhen Sun
XXXian Xiao
Xian Xiao
YZYuxin Zhang
Yuxin Zhang
Jing YangJing Yang
Jing Yang
This study investigates the characteristics of space-borne Lightning Mapping Imager (LMI) lightning products and their relationships with cloud properties using ground-based total lightning observations from the Beijing Broadband Lightning Network (BLNET) and cloud information from S-band Doppler radar data. LMI showed generally consistent lightning spatial distributions with those of BLNET, and yielded a considerable lightning detection capability over regions with complex terrain. The ratios between the LMI events, groups and flashes were approximately 9:3:1, and the number of LMI-detected flashes was roughly one order of magnitude smaller than the number of BLNET-detected flashes. However, in different convective episodes, the LMI detection capability was likely to be affected by cloud properties, especially in strongly electrified convective episodes associated with frequent lightning discharging and thick cloud depth. As a result, LMI tended to detect lightning flashes located in weaker and shallower cloud portions associated with fewer cloud shielding effects. With reference to the BLNET total lightning data as the ground truth of observation (both intra-cloud lightning and cloud-to-ground lightning flashes), the LMI event-based detection efficiency (DE) was estimated to reach 28% under rational spatiotemporal matching criteria (1.5 s and 65 km) over Beijing. In terms of LMI flash-based DE, it was much reduced compared with event-based DE. The LMI flash-based ranged between 1.5% and 3.5% with 1.5 s and 35–65 km matching scales. For 330 ms and 35 km, the spatiotemporal matching criteria used to evaluate Geostationary Lightning Mapper (GLM), the LMI flash-based DE was smaller (<1%).

21 May 2020 in Scientific Reports
Verified
Journal Article
Open access
BOBabalola O. Ogunsua
Babalola O. Ogunsua
ASAbhay Srivastava
Abhay Srivastava
JBJ. Bian
J. Bian
XQXiushu Qie
Xiushu Qie
DWD. Wang
D. Wang
Jing YangJing Yang
Jing Yang
The equatorial Congo has been recognized as the most active lightning chimney region in the Globe. Although the perturbation of tropospheric thunderstorms on the lower ionosphere has been noticed in the middle latitudes through their transient lightning electric fields or convective gravity waves, the effects on equatorial ionosphere and the horizontal extent of this perturbation remains a mystery because of the difficulties in extracting the effects due to the sporadic nature of the equatorial ionosphere. Here we present observational results showing solid evidence of deviations in ionospheric total electron content (TEC) and its direction of propagation associated with thunderstorms using the method of polynomial filtering, by utilizing the TEC measured from equatorial Global Positioning System (GPS) Receiver stations along the West African region-Congo Basin. The TEC deviations due to the thunderstorms were found to be mostly propagated in a specific direction from the point of the event, with the highest absolute peak TEC at ~±1.5 TECUs. The internal dynamics of the equatorial ionosphere have been found to be suppressed by large thunderstorm effects during the daytime, with negligible impact at night.

16 August 2020 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
Jing YangJing Yang
Jing Yang
XQXiushu Qie
Xiushu Qie
LZLihua Zhong
Lihua Zhong
QHQijia He
Qijia He
GLGaopeng Lu
Gaopeng Lu
HLHualong Li
Hualong Li
At about 22:43:30 BJT (Beijing Time = UTC + 8) on 13 August 2016, two amateur astronomers in Shikengkong, Guangdong province, and Jiahe County, Hunan province, respectively, fortuitously captured a gigantic jet (GJ) event simultaneously, and the GJ exact location could be triangulated. The parent thunderstorm was in a very humid environment (Precipitable Water [PWAT] in excess of 60 mm), featuring high convective available potential energy (CAPE of 2,428 J/kg). The GJ occurred in the region with the coldest cloud top brightness temperature of −64 °C, suggesting the GJ was associated with strong vertical development of the thunderstorm. The vertical cross sections of radar reflectivity also show that the GJ occurred near the thunderstorm strong convection region (overshooting top). The negative cloud‐to‐ground flashes dominated during the thunderstorm evolution. Three positive narrow bipolar events (NBEs) were detected within 30 s before and after the GJ. It indicates that the NBEs were occurred in the upper and middle layers of the thunderstorm (altitude of 11–13 km) with radar reflectivity of 30–35 dBZ.

6 August 2018 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
Jing YangJing Yang
Jing Yang
NLNingyu Liu
Ningyu Liu
Mitsuteru SatoMitsuteru Sato
Mitsuteru Sato
GLGaopeng Lu
Gaopeng Lu
YWYu Wang
Yu Wang
GFGuili Feng
Guili Feng
This paper reports observation of five sprites captured over a mesoscale convective system in a 15‐min window. One of them (11:49 hr sprite) was preceded by a negative cloud‐to‐ground with peak current of −40.9 kA that was detected both by the local lightning detection network (sprite time delay <70–90 ms) and the extremely low frequency (ELF) magnetic field data. Another sprite (11:46 hr sprite) was preceded by a negative stroke (sprite time delay <10 ms) with peak current of −106.6 kA but the ELF signal of the stroke could not be recognized. In addition, no positive strokes were recorded 1.5 min before the 11:46 hr sprite. The rest of the sprites were confirmed as positive both by the local lightning detection network and the ELF magnetic field data. The negative sprite occurred during strong convection, indicated by the increase of the area of the thundercloud with radar echo top of 8–11, 9–11, and 6–12 km. The strong convection and large wind shear in the thunderstorm middle and upper region provide favorable conditions to produce the parent cloud‐to‐ground lightning discharges of the negative sprites.