Xinyi Xie

Dr. Xinyi Xie

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2021 in Remote Sensing
Verified
Journal Article
Open access
PDF file
HHHaocai Huang
Haocai Huang
SXshijie xu
shijie xu
XXXinyi Xie
Xinyi Xie
YGYong Guo
Yong Guo
LMLuwen Meng
Luwen Meng
GLguangming Li
guangming Li
The continuous sensing of water parameters is of great importance to the study of dynamic processes in the ocean, coastal areas, and inland waters. Conventional fixed-point and ship-based observing systems cannot provide sufficient sampling of rapidly varying processes, especially for small-scale phenomena. Acoustic tomography can achieve the sensing of water parameter variations over time by continuously using sound wave propagation information. A multi-station acoustic tomography experiment was carried out in a reservoir with three sound stations for water temperature observation. Specifically, multi-path propagation sound waves were identified with ray tracing using high-precision topography data obtained with ship-mounted ADCP. A new grid inverse method is proposed in this paper for water temperature profiling along a vertical slice. The progression of water temperature variation in three vertical slices between acoustic stations was mapped by solving an inverse problem. The reliability and adaptability of the grid method developed in this research are verified by comparison with layer-averaged water temperature results. The grid method can be further developed for the 3D mapping of water parameters over time, especially in small-scale water areas, where sufficient multi-path propagation sound waves can be obtained.

9 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SXshijie xu
shijie xu
ZXZhao Xue
Zhao Xue
XXXinyi Xie
Xinyi Xie
HHHaocai Huang
Haocai Huang
GLguangming Li
guangming Li
Continuous sensing of water parameters is of great importance to fluid dynamic progress study in oceans, coastal areas and inland waters. The acoustic tomography technique can perform water temperature field measurements horizontally and vertically using sound wave travel information. The layer-averaged water temperature can also be measured with the acoustic tomography method. However, investigations focusing on the stratified mechanism, which consists of stratification form and its influence on inversion error, are seldom performed. In this study, an acoustic tomography experiment was carried out in a reservoir along two vertical slices to observe the layer-averaged water temperature. Specifically, multi-path sound travel information is identified through ray tracing using high-precision topography data obtained via a ship-mounted ADCP during the experiment. Vertical slices between sound stations are divided into different layers to study layer division inversion methods in different preset types. The inversion method is used to calculate the average water temperature and inversion temperature error of every layer. Different layer methods are studied with a comparison of results. The layer division principle studied in this paper can be used for layer-averaged water temperature sensing with multi-path sound transmission information.

9 January 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YGYixin Gao
Yixin Gao
XXXinyi Xie
Xinyi Xie
GLguangming Li
guangming Li
ZHZhengliang Hu
Zhengliang Hu
PXPan Xu
Pan Xu
HHHaocai Huang
Haocai Huang
High-precision and spatiotemporal flow field measurement in small-scale waters has a decisive impact on navigation and water resource management.Multi transmission rays and position drift, as two main difficulties in improving the accuracy of small-scale flow field, need to be solved urgently. In this paper, four coastal acoustic tomography (CAT) systems are arranged in Qingyang Lake, Hunan, China on 1, March 2022 for a short-term observation. As the GPS error and shipping caused station drift contaminate the reconstructed flow field, a real-time station position correction method, based on travel time and Temperature, Depth sensors (TD), is applied in our inversion. The inversion range average current (RAC) is in agreement with forward calculation, which proves the reliability of the reconstructed horizontal flow field. Besides, comparisons of net flow and Acoustic Doppler Current Profiler (ADCP) velocity are performed to validate the improvement of the real-time station position correction algorithm. The errors of corrected net flow are less than 3.818 m 2 /s, with a minimum of 0.0042 m 2 /s. The root-mean-square error (RMSE) between the CAT inversion results and the ADCP velocity is 0.123 m/s after correction, relatively reduced 5.95% than before correction. The smaller the RMSE, the higher the inversion accuracy, so the CAT method with real-time station position correction is feasible for high-precision horizontal flow field reconstruction.

17 January 2026 in Thin-Walled Structures
Verified
Journal Article
Closed access
HJHuaqing Jin
Huaqing Jin
XLXiaofan Li
Xiaofan Li
RDRui Ding
Rui Ding
XXXinyi Xie
Xinyi Xie
JZJiaxin Zhou
Jiaxin Zhou
HZHaicheng Zhang
Haicheng Zhang