Raymond Laflamme

Prof. Dr. Raymond Laflamme

Institute for Quantum Computing and Department of Physics and Astronomy, University of Waterloo, Waterloo, ON N2L 3G1, Canada

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2009 in Physical Review A
Verified
Journal Article
Closed access
PDF file
JZJingfu Zhang
Jingfu Zhang
Fernando CucchiettiFernando Cucchietti
Fernando Cucchietti
CCC. M. Chandrashekar
C. M. Chandrashekar
MLMartin Laforest
Martin Laforest
CRColm A. Ryan
Colm A. Ryan
RLRaymond Laflamme
Raymond Laflamme
We use NMR quantum simulators to study antiferromagnetic Ising spin chains undergoing quantum phase transitions. Taking advantage of the sensitivity of the systems near criticality, we detect the critical points of the transitions using a direct measurement of the Loschmidt echo. We test our simulators for spin chains of even and odd numbers of spins, and compare the experimental results to theoretical predictions.

8 April 2015 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
DLDawei Lu
Dawei Lu
HLHang Li
Hang Li
DTDenis-Alexandre Trottier
Denis-Alexandre Trottier
JLJun Li
Jun Li
ABAharon Brodutch
Aharon Brodutch
RLRaymond Laflamme
Raymond Laflamme
One of the major experimental achievements in the past decades is the ability to control quantum systems to high levels of precision. To quantify the level of control we need to characterize the dynamical evolution. Full characterization via quantum process tomography is impractical and often unnecessary. For most practical purposes, it is enough to estimate more general quantities such as the average fidelity. Here we use a unitary 2-design and twirling protocol for efficiently estimating the average fidelity of Clifford gates, to certify a 7-qubit entangling gate in a nuclear magnetic resonance quantum processor. Compared with more than 108 experiments required by full process tomography, we conducted 1656 experiments to satisfy a statistical confidence level of 99%. The average fidelity of this Clifford gate in experiment is 55.1%, and rises to at least 87.5% if the signal’s decay due to decoherence is taken into account. The entire protocol of certifying Clifford gates is efficient and scalable, and can easily be extended to any general quantum information processor with minor modifications.

20 December 2016 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
GFGuanru Feng
Guanru Feng
JWJoel J. Wallman
Joel J. Wallman
BBBrandon Buonacorsi
Brandon Buonacorsi
FCFranklin H. Cho
Franklin H. Cho
DPDaniel K. Park
Daniel K. Park
RLRaymond Laflamme
Raymond Laflamme
To exploit a given physical system for quantum information processing, it is critical to understand the different types of noise affecting quantum control. Distinguishing coherent and incoherent errors is extremely useful as they can be reduced in different ways. Coherent errors are generally easier to reduce at the hardware level, e.g., by improving calibration, whereas some sources of incoherent errors, e.g., T2* processes, can be reduced by engineering robust pulses. In this work, we illustrate how purity benchmarking and randomized benchmarking can be used together to distinguish between coherent and incoherent errors and to quantify the reduction in both of them due to using optimal control pulses and accounting for the transfer function in an electron spin resonance system. We also prove that purity benchmarking provides bounds on the optimal fidelity and diamond norm that can be achieved by correcting the coherent errors through improving calibration.

17 August 2012 in Physical Review Letters
Verified
Journal Article
Closed access
OMOsama Moussa
Osama Moussa
MSMarcus P. da Silva
Marcus P. da Silva
CRColm A. Ryan
Colm A. Ryan
RLRaymond Laflamme
Raymond Laflamme
Because of the technical difficulty of building large quantum computers, it is important to be able to estimate how faithful a given implementation is to an ideal quantum computer. The common approach of completely characterizing the computation process via quantum process tomography requires an exponential amount of resources, and thus is not practical even for relatively small devices. We solve this problem by demonstrating that twirling experiments previously used to characterize the average fidelity of quantum memories efficiently can be easily adapted to estimate the average fidelity of the experimental implementation of important quantum computation processes, such as unitaries in the Clifford group, in a practical and efficient manner with applicability in current quantum devices. Using this procedure, we demonstrate state-of-the-art coherent control of an ensemble of magnetic moments of nuclear spins in a single crystal solid by implementing the encoding operation for a 3-qubit code with only a 1% degradation in average fidelity discounting preparation and measurement errors. We also highlight one of the advances that was instrumental in achieving such high fidelity control.

1 November 2017 in New Journal of Physics
Verified
Journal Article
Open access
PDF file
NRNayeli A Rodríguez-Briones
Nayeli A Rodríguez-Briones
JLJun Li
Jun Li
XPXinhua Peng
Xinhua Peng
TMTal Mor
Tal Mor
YWYossi Weinstein
Yossi Weinstein
RLRaymond Laflamme
Raymond Laflamme
Cooling techniques are essential to understand fundamental thermodynamic questions of the lowenergy states of physical systems, furthermore they are at the core of practical applications of quantum information science. In quantum computing, this controlled preparation of highly pure quantum states is required from the state initialization of most quantum algorithms to a reliable supply of ancilla qubits that satisfy the fault-tolerance threshold for quantum error correction. Heat-bath algorithmic cooling has been shown to purify qubits by controlled redistribution of entropy and multiple contact with a bath, not only for ensemble implementations but also for technologies with strong but imperfect measurements. In this paper, we show that correlated relaxation processes between the system and environment during rethermalization when we reset hot ancilla qubits, can be exploited to enhance purification. We show that a long standing upper bound on the limits of algorithmic cooling Schulman et al (2005 Phys. Rev. Lett. 94, 120501) can be broken by exploiting these correlations. We introduce a new tool for cooling algorithms, which we call 'state-reset', obtained when the coupling to the environment is generalized from individual-qubits relaxation to correlated-qubit relaxation. Furthermore, we present explicit improved cooling algorithms which lead to an increase of purity beyond all the previous work, and relate our results to the Nuclear Overhauser Effect.

26 November 2018 in Physical Review A
Verified
Journal Article
Closed access
PDF file
GFGuanru Feng
Guanru Feng
FCFranklin H. Cho
Franklin H. Cho
HKHemant Katiyar
Hemant Katiyar
JLJun Li
Jun Li
DLDawei Lu
Dawei Lu
RLRaymond Laflamme
Raymond Laflamme
Quantum optimal control can play a crucial role in realizing a set of universal quantum logic gates with error rates below the threshold required for fault tolerance. Open-loop quantum optimal control relies on accurate modeling of the quantum system under control and does not scale efficiently with system size. These problems can be avoided in closed-loop quantum optimal control, which utilizes feedback from the system to improve control fidelity. In this paper, two gradient-based closed-loop quantum optimal control algorithms, the hybrid quantum-classical approach (HQCA) described by Li et al. [ Phys. Rev. Lett. 118, 150503 (2017)] and the finite-difference (FD) method, are experimentally investigated and compared to the open-loop quantum optimal control utilizing the gradient ascent method. We employ a solid-state ensemble of coupled electron-nuclear spins serving as a two-qubit system. Specific single-qubit and two-qubit state preparation gates are optimized using the closed-loop and open-loop methods. The experimental results demonstrate the implemented closed-loop quantum control outperforms the open-loop control in our system. Furthermore, simulations reveal that HQCA is more robust than the FD method to gradient noise which originates from measurement noise in this experimental setting. On the other hand, the FD method is more robust to control field distortions coming from nonideal hardware.