Olamide Eso

Ms. Olamide Eso


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2025 in Energies
Verified
Journal Article
Open access
PDF file
OEOlamide Eso
Olamide Eso
Jo DarkwaJo Darkwa
Jo Darkwa
John Kaiser CalautitJohn Kaiser Calautit
John Kaiser Calautit
Windcatchers are effective passive ventilation systems, but their inability to actively reduce and stabilize supply air temperatures reduces indoor cooling performance. This study addresses this limitation by integrating encapsulated phase-change material tubes (E-PCM-Ts) into a solar fan-assisted, multidirectional windcatcher. The novelty lies in the vertical placement of E-PCM-Ts within the windcatcher’s airstreams, enhancing heat transfer and addressing challenges related to temperature stabilization and cooling. Using computational fluid dynamics (CFD) under hot outdoor conditions, the ventilation, cooling, and PCM thermal storage performance are evaluated based on two different E-PCM-T arrangements. Results showed a maximum air temperature drop of 2.28 °C at a wind speed of 1.88 m/s and wind angle of 0°. This offers an optimal temperature reduction that achieved a 6.5% reduction for up to 7 h of air temperature stabilization. Placing E-PCM-Ts in all airstreams improved the thermal storage performance of the windcatcher. A 50% increase in hybrid ventilation efficiency was also achieved when wind angles increased from 0° to 30°. Overall, the proposed system demonstrated superior performance compared to that of traditional windcatchers, delivering improved thermal energy storage and cooling efficiency and adequate hybrid ventilation with supply air velocities of 0.37–0.60 m/s.

24 January 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
OEOlamide Eso
Olamide Eso
Jo DarkwaJo Darkwa
Jo Darkwa
John Kaiser CalautitJohn Kaiser Calautit
John Kaiser Calautit
Windcatchers are widely recognized as effective passive ventilation systems. Moreover, the incorporation of fans for hybrid ventilation has been explored in research to improve windcatchers’ ventilation in low wind conditions. Nonetheless, significant limitations persist, particularly the inability to actively reduce and stabilize supply air temperatures for effective indoor cooling. Incorporating phase change materials (PCM) in windcatchers can potentially stabilize air temperatures to improve windcatchers’ cooling performance. However, this area of study remains underexplored. To address this gap, this study proposes an innovative integration of encapsulated phase change material tubes (E-PCM-T) into a four-sided solar-fan-assisted multi-directional windcatcher. The novelty lies in vertically placing E-PCM-T within the windcatcher’s airstreams, enhancing heat transfer, and addressing the challenge of low-temperature stabilisation and cooling. Using computational fluid dynamics (CFD), the study assesses how varying wind speeds, wind angles, and E-PCM-T configurations impact the windcatcher’s thermal energy storage, cooling, and overall ventilation performance in typical hot outdoor conditions, based on validated CFD models. Results indicate that E-PCM-T arrangement affects airflow, temperature reduction, and the system's cooling capacity duration. The maximum air temperature drop achieved was 2.28 °C at 1.88 m/s wind speed and a 0 ° wind angle, offering a 6.5 % temperature reduction with air temperature stabilisation for up to 7 hours. Accordingly, the impact of wind angle variation on the hybrid ventilation performance of the system was more noticeable when E-PCM-T were placed in all the airstreams. When the wind angle changed from 0 o to 30 o, with the inclusion of the solar fan, a 50 % increase in the hybrid ventilation performance was seen. Overall, the system demonstrated superior performance over traditional windcatchers in terms of thermal energy storage and cooling efficiency, while still offering adequate hybrid ventilation at 0.37 - 0.60 m/s supply air velocity range.