Nipapan Ruecha

Dr. Nipapan Ruecha

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2022 in Talanta
Verified
Journal Article
Closed access
KTKanyapat Teekayupak
Kanyapat Teekayupak
CAChuanchom Aumnate
Chuanchom Aumnate
ALAtchara Lomae
Atchara Lomae
PPPattarachaya Preechakasedkit
Pattarachaya Preechakasedkit
CHCharles S. Henry
Charles S. Henry
NRNipapan Ruecha
Nipapan Ruecha

28 August 2023 in Analytical Chemistry
Verified
Journal Article
Closed access
PPPattarachaya Preechakasedkit
Pattarachaya Preechakasedkit
WPWattana Panphut
Wattana Panphut
ALAtchara Lomae
Atchara Lomae
WWWanida Wonsawat
Wanida Wonsawat
DCDaniel Citterio
Daniel Citterio
NRNipapan Ruecha
Nipapan Ruecha

8 October 2022 in Talanta
Verified
Journal Article
Closed access
ALAtchara Lomae
Atchara Lomae
PPPattarachaya Preechakasedkit
Pattarachaya Preechakasedkit
OHOrakan Hanpanich
Orakan Hanpanich
TOTugba Ozer
Tugba Ozer
CHCharles S. Henry
Charles S. Henry
NNNattaya Ngamrojanavanich
Nattaya Ngamrojanavanich

1 June 2021 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
NJNopparat Janmee
Nopparat Janmee
PPPattarachaya Preechakasedkit
Pattarachaya Preechakasedkit
NRNadnudda Rodthongkum
Nadnudda Rodthongkum
OCOrawon Chailapakul
Orawon Chailapakul
PPPranut Potiyaraj
Pranut Potiyaraj
NRNipapan Ruecha
Nipapan Ruecha
A non-enzymatic disposable electrochemical sensor coupled with an automated sample pretreatment paper-based device was developed to avoid an additional sample preparation step for glucose determination in human urine and electrolyte drinks. The automated sample pretreatment paper-based device was successfully fabricated by the simple coating of a strong alkaline solution on a patterned wax paper, and then attached on an electrochemical sensor. The nanocomposite of copper oxide nanoparticles, ionic liquid and reduced graphene oxide (CuO-IL/rGO) modified on the screen-printed carbon electrode (SPCE) was created and used as a non-enzymatic electrochemical glucose sensor. The presence of the CuO-IL/rGO nanocomposite on the screen-printed electrode surface was confirmed by transmission electron microscopy (TEM), scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDX), and X-ray diffraction spectroscopy (XRD). Under optimal conditions, glucose was measured by dropping 100 μL sample solution on the device and detected via chronoamperometry (CA) using a smartphone potentiostat controlled by Android app., providing a rapid current response within 20 s and linearity in a range of 0.03–7.0 mM with a limit of detection (LOD) of 0.14 μM. Furthermore, this developed device was successfully applied for determining glucose levels in human urine and electrolyte drinks, exporting satisfying results correlated with a commercial enzymatic glucose biosensor and labeled values of the commercial products. Therefore, this device could be an alternative device for a non-enzymatic glucose sensor with single-step sample loading, allowing for real-time analysis, low cost, portability, disposability, and on-field measurement.

24 May 2023 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
KTKanyapat Teekayupak
Kanyapat Teekayupak
ALAtchara Lomae
Atchara Lomae
IAIsmail Agir
Ismail Agir
NCNatthaya Chuaypen
Natthaya Chuaypen
TDThasinas Dissayabutra
Thasinas Dissayabutra
NRNipapan Ruecha
Nipapan Ruecha

24 July 2024 in Talanta
Verified
Journal Article
Closed access
ALAtchara Lomae
Atchara Lomae
KTKanyapat Teekayupak
Kanyapat Teekayupak
PPPattarachaya Preechakasedkit
Pattarachaya Preechakasedkit
EPEkawat Pasomsub
Ekawat Pasomsub
TOTugba Ozer
Tugba Ozer
NRNipapan Ruecha
Nipapan Ruecha