Longitudinal intrafascicular electrodes (LIFEs) are electrodes designed to be placed inside the peripheral nerve to improve stimulation selectivity and to increase the recording signal-to-noise ratio. We evaluated the functional and morphological effects of either Pt wire LIFEs or polyimide-based thin-film LIFEs implanted in the rat sciatic nerve for 3 mo. The newly designed thin-film LIFEs are more flexible, can be micromachined and allow placement of more active electrode sites than conventional Pt LIFEs. Functional results at 1 mo indicated an initial decline in the nerve conduction velocity and in the amplitude of muscle responses, which recovered during the following 2 mo towards normal values. Morphological results showed that both types of LIFEs induced a mild scar response and a focal but chronic inflammatory reaction, which were limited to a small area around the electrode placed in the nerve. Both types of LIFEs can be considered biocompatible and cause reversible, minimal nerve damage
1 May 1993 in IEEE Transactions on Biomedical Engineering
We have studied activation of nerve fibers by pairs of Pt-Ir wire electrodes implanted within single fascicles of the nerve innervating the gastrocnemius muscle in cats. The purpose of this study was to determine if these intrafascicular electrodes can activate nerve fibers in different fascicles independently of each other and if they can also be used to activate separate subsets of axonal populations within a single fascicle. The average overlap of activated nerve fiber populations was 5.5% between fascicles and 27% within a fascicle, indicating that such selective activation is possible with these electrodes.
14 June 2002 in Journal of Micromechanics and Microengineering
We tested the hypothesis that the neural networks for walking in the mudpuppy can be divided into a flexor and an extensor center, each of which contains collections of interneurons localized in the vicinity of their motoneuron pools. Combining a battery of techniques, we identified and localized the elbow flexor center and its motoneuron pool in the C2 segment and the elbow extensor center and its motoneuron pool in the C3 segment. Rhythmic flexion or extension of the limb in isolation could be induced by continuous trains of current pulses of the C2 or C3 segments, respectively. Independent activation could also occur after application of glutamate receptor agonist NMDA. Part of segment C2 in isolation generated rhythmic elbow flexor bursts, whereas part of segment C3 in isolation generated rhythmic elbow extensor bursts. An isolated region spanning the C3 roots generated both flexor and extensor bursts. The step cycle was modulated in a phase-dependent manner by stimulation of the dorsal roots, the ventral roots, or either of the two centers. The effects of ventral root stimulation were removed by deafferentation to block reafferent input attributable to muscle contraction induced by the stimulation. We conclude that the neural networks for walking contain at least a flexor and an extensor generator that are localized in close apposition to the motoneuron pools, that the two centers can work independently despite the fact that there are reciprocal inhibitory interconnections between them, and that sensory input interacts with the spinal neural networks to reset the ongoing walking rhythm in a phase-dependent manner.
18 April 2006 in IEEE Transactions on Biomedical Engineering
The mechanical behavior of an electrode during implantation into neural tissue can have a profound effect on the neural connections and signaling that takes place within the tissue. The objective of the present work was to investigate the in vivo implant mechanics of flexible, silicon-based ACREO microelectrode arrays recently developed by the VSAMUEL consortium (European Union, grant #IST-1999-10073). We have previously reported on both the electrical [1]-[3] and mechanical [4], [5] properties of the ACREO electrodes. In this paper, the tensile and compression forces were measured during a series of in vivo electrode insertions into the cerebral cortex of rats (7 acute experiments, 2-mm implant depth, 2-mm/s insertion velocity). We compared the ACREO silicon electrodes (4' opening angle, 1-8 shafts) to single-shaft tungsten electrodes (3' and 10' opening angles). The penetration force and dimpling increased with the cross-sectional area (statistical difference between the largest and the smallest electrode) and with the number of shafts (no statistical difference). We consistently observed tensile (drag) forces during the retraction phase, which indicates the brain tissue sticks to the electrode within a short time period. Treating the electrodes prior to insertion with silane (hydrophobic) or piranha (hydrophilic) significantly decreased the penetration force. In conclusion, our findings suggest that reusable electrodes for acute animal experiments must not only be strong enough to survive a maximal force that exceeded the penetration force, but must also be able to withstand high tension forces during retraction. Careful cleaning is not only important to avoid foreign body response, but can also reduce the stress applied to the electrode while penetrating the brain tissue