María. A. Fernández-Seara

Dr. María. A. Fernández-Seara

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2008 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
Ze WangZe Wang
Ze Wang
GAGeoffrey K. Aguirre
Geoffrey K. Aguirre
HRHengyi Rao
Hengyi Rao
JWJiongjiong Wang
Jiongjiong Wang
MFMaría. A. Fernández-Seara
María. A. Fernández-Seara
JDJohn A. Detre
John A. Detre

29 October 2007 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
WWWen‐Chau Wu
Wen‐Chau Wu
MFMaría. A. Fernández-Seara
María. A. Fernández-Seara
JDJohn A. Detre
John A. Detre
FWFelix W. Wehrli
Felix W. Wehrli
JWJiongjiong Wang
Jiongjiong Wang
Arterial spin labeling (ASL) is capable of noninvasively measuring blood flow by magnetically tagging the protons in arterial blood, which has been conventionally achieved using instantaneous (PASL) or continuous (CASL) RF pulses. As an intermediate method, pseudocontinuous ASL (pCASL) utilizes a train of discrete RF pulses to mimic continuous tagging that is often unavailable on imagers due to the requirement of continuous RF transmit capabilities. In the present study, we implemented two versions of pCASL (balanced and unbalanced gradient waveforms in tag and control scans) for both transmit/receive coils and array receivers. Experimental data show a 50% ± 4% increase of signal‐to‐noise ratio (SNR) compared with PASL and a higher tagging efficiency than amplitude‐modulated (AM) CASL (80% vs. 68%). Computer simulations predict an optimal tagging efficiency of 85% for flow velocities from 10 to 60 cm/s. It is theoretically and experimentally demonstrated that the tagging efficiency of pCASL is dependent upon the resonance offset and flip angle of the RF pulse train. We conclude that pCASL has the potential of combining the merits of PASL, including less hardware demand and higher tagging efficiency, and CASL, which includes a longer tagging bolus and thus higher SNR. These improvements provide a better balance between tagging efficiency and SNR. Magn Reson Med 58:1020–1027, 2007.

15 March 2015 in Movement Disorders
Verified
Journal Article
Closed access
PDF file
GCGabriel Castellanos
Gabriel Castellanos
MFMaría. A. Fernández-Seara
María. A. Fernández-Seara
OLOswaldo Lorenzo‐Betancor
Oswaldo Lorenzo‐Betancor
SOSara Ortega‐Cubero
Sara Ortega‐Cubero
MPMarc Puigvert
Marc Puigvert
MPMaria Pastor
Maria Pastor

1 February 2013 in NeuroImage
Verified
Journal Article
Closed access
MVMarta Vidorreta
Marta Vidorreta
ZWZe Wang
Ze Wang
IRIgnacio Rodríguez
Ignacio Rodríguez
MPMaria Pastor
Maria Pastor
JDJohn A. Detre
John A. Detre
MFMaría. A. Fernández-Seara
María. A. Fernández-Seara

23 August 2018 in Nephrology Dialysis Transplantation
Verified
Journal Article
Open access
PDF file
AOAghogho Odudu
Aghogho Odudu
FNFabio Nery
Fabio Nery
AHAnita A Harteveld
Anita A Harteveld
RERoger G Evans
Roger G Evans
DPDouglas Pendse
Douglas Pendse
MFMaría. A. Fernández-Seara
María. A. Fernández-Seara
Renal perfusion provides the driving pressure for glomerular filtration and delivers the oxygen and nutrients to fuel solute reabsorption. Renal ischaemia is a major mechanism in acute kidney injury and may promote the progression of chronic kidney disease. Thus, quantifying renal tissue perfusion is critically important for both clinicians and physiologists. Current reference techniques for assessing renal tissue perfusion have significant limitations. Arterial spin labelling (ASL) is a magnetic resonance imaging (MRI) technique that uses magnetic labelling of water in arterial blood as an endogenous tracer to generate maps of absolute regional perfusion without requiring exogenous contrast. The technique holds enormous potential for clinical use but remains restricted to research settings. This statement paper from the PARENCHIMA network briefly outlines the ASL technique and reviews renal perfusion data in 53 studies published in English through January 2018. Renal perfusion by ASL has been validated against reference methods and has good reproducibility. Renal perfusion by ASL reduces with age and excretory function. Technical advancements mean that a renal ASL study can acquire a whole kidney perfusion measurement in less than 5–10 min. The short acquisition time permits combination with other MRI techniques that might inform drug mechanisms and renal physiology. The flexibility of renal ASL has yielded several variants of the technique, but there are limited data comparing these approaches. We make recommendations for acquiring and reporting renal ASL data and outline the knowledge gaps that future research should address.

5 April 2006 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
MFMaría. A. Fernández-Seara
María. A. Fernández-Seara
ATAranee Techawiboonwong
Aranee Techawiboonwong
JDJohn A. Detre
John A. Detre
FWFelix W. Wehrli
Felix W. Wehrli
Monitoring of oxygen saturation in jugular venous blood gives an estimate of the balance of global oxygen delivery and cerebral oxygen consumption. We present a noninvasive approach to measure oxygen saturation in vivo in the internal jugular vein using MR susceptometry by exploiting the characteristic susceptibility of deoxyhemoglobin, and demonstrate the feasibility of performing such measurements in a group of subjects. We assessed the sensitivity of the method for detecting small changes in oxygen saturation by monitoring the variations observed during breath‐holding and hypoventilation experiments. Unlike alternative methods, the susceptometric technique does not require calibration. Magn Reson Med, 2006.