Richard M Mariita

Dr. Richard M Mariita

Crystal IS Inc., an Asahi Kasei company, 70 Cohoes Avenue, Green Island, New York, 12183, USA
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2022 in Microbiologyopen
Verified
Journal Article
Open access
PDF file
RMRichard M Mariita
Richard M Mariita
JDJames Davis
James Davis
MLMichelle M. Lottridge
Michelle M. Lottridge
RRRajul V. Randive
Rajul V. Randive
Candida auris is an emerging fungal superbug of worldwide interest. It is associated with high mortality rates and exhibits increased resistance to antifungals. Ultraviolet subtype C (UVC) light can be used to disinfect surfaces to mitigate its spread. The objectives of this study were (1) To investigate UVC disinfection performances and wavelength sensitivity of C. auris. (2) To evaluate the UVC dose required for the prevention of biofilm formation on stainless‐steel, plastic (polystyrene), and poly‐cotton fabric surfaces. C. auris was grown following standard procedures. The study utilized six different UVC LED arrays with wavelengths between 252 and 280 nm. Arrays were set at similar intensities, to obtain doses of 5–40 mJ cm−2 and similar irradiation time. Disinfection performance for each array was determined using log reduction value (LRV) and percentage reduction by comparing the controls against the irradiated treatments. Evaluation of the ability of 267 nm UVC LEDs to prevent C. auris biofilm formation was investigated using stainless‐steel, plastic coupons, and poly‐cotton fabric. Peak sensitivity to UVC disinfection was between 267 and 270 nm. With 20 mJ cm−2, the study obtained ≥LRV3. On stainless‐steel coupons, 30 mJ cm−2 was sufficient to prevent biofilm formation, while on plastic, this required 10 mJ cm−2. A dose of 60 mJ cm−2 reduced biofilms on poly‐cotton fabric significantly (R2 = 0.9750, p = 0.0002). The study may allow for the design and implementation of disinfection systems.

3 September 2021 in Frontiers in Microbiology
Verified
Journal Article
Open access
RMRichard M Mariita
Richard M Mariita
SBSébastien A. Blumenstein
Sébastien A. Blumenstein
CBChristian M. Beckert
Christian M. Beckert
TGThomas Gombas
Thomas Gombas
RRRajul V. Randive
Rajul V. Randive
The purgaty One systems (cap+bottle) are portable stainless-steel water bottles with UV subtype C (UVC) disinfection capability. This study examines the bottle design, verifies disinfection performance against Escherichia coli, Pseudomonas aeruginosa, Vibrio cholerae, and heterotrophic contaminants, and addresses the public health relevance of heterotrophic bacteria. Bottles were inoculated with deliberately contaminated potable water and disinfection efficacy examined using colony forming unit (CFU) assay for each bacterial strain. The heterotrophic plate count (HPC) method was used to determine the disinfection performance against environmental contaminants at day 0 and after 3days of water in stationary condition without prior UVC exposure. All UVC irradiation experiments were performed under stationary conditions to confirm that the preset application cycle of 55s offers the desired disinfection performance under-tested conditions. To determine effectiveness of purgaty One systems (cap+bottle) in disinfection, inactivation efficacy or log reduction value (LRV) was determined using bacteria concentration between UVC ON condition and controls (UVC OFF). The study utilized the 16S ribosomal RNA (rRNA) gene for characterization of isolates by identifying HPC bacteria to confirm if they belong to groups that are of public health concern. Purgaty One systems fitted with Klaran UVC LEDs achieved 99.99% inactivation (LRV4) efficacy against E. coli and 99.9% inactivation (LRV3) against P. aeruginosa, V. cholerae, and heterotrophic contaminants. Based on the 16S rRNA gene analyses, the study determined that the identified HPC isolates from UVC irradiated water are of rare public health concern. The bottles satisfactorily inactivated the target pathogenic bacteria and HPC contaminants even after 3days of water in stationary condition.

1 November 2023 in Access Microbiology
Verified
Journal Article
Open access
Silas Onyango AwuorSilas Onyango Awuor
Silas Onyango Awuor
EOEric Omori Omwenga
Eric Omori Omwenga
RMRichard M Mariita
Richard M Mariita
JMJonathan M. Musila
Jonathan M. Musila
SMStanslaus Musyoki
Stanslaus Musyoki
Antibiotic resistance poses a grave global public health threat, exacerbated by widespread and often inappropriate antibiotic usage. Vigilant surveillance of antibiotic utilization and emergence of antimicrobial resistance (AMR) is essential. Of particular concern in the era of AMR is the persistent issue of chronic wound infections. To address this, we conducted a comprehensive evaluation of wound isolates from chronic wounds at Jaramogi Oginga Odinga Teaching and Referral Hospital (JOOTRH) in Kenya, to identify relevant bacteria and assess their drug resistance patterns.Wound samples were collected and processed using standard microbiological methods. Bacterial isolates were identified and assessed for their susceptibility to a panel of antibiotics using the Kirby-Bauer disk diffusion method. A total of 103 bacterial isolates were obtained from the wound samples, with a higher prevalence in male patients (59%). Staphylococcus aureus (20.7 %) emerged as the most predominant pathogen, followed by Klebsiella spp. (14.8 %), Pseudomonas aeruginosa spp. (14.8 %) and Escherichia coli (4.4 %) in wound samples. High levels of antibiotic resistance were observed among the isolates, with the highest resistance rates reported for cotrimoxazole (48.1 %), clindamycin (25.9 %) and erythromycin (25.9 %). Furthermore, among the isolates, 75 % produced haemolysin and protease, while 50 % produced lipase and phospholipase, factors that enhance virulence and survival. The findings of this study highlight the alarmingly high prevalence of antibiotic resistance among bacterial pathogens isolated from chronic wounds in Kenya. This poses a major challenge to the effective management of chronic wound infections. There is an urgent need to implement effective antimicrobial stewardship programs and develop new antibiotics to combat the growing threat of antibiotic resistance.

7 October 2021 in Frontiers in Built Environment
Verified
Journal Article
Open access
KKKevin Kahn
Kevin Kahn
RMRichard M Mariita
Richard M Mariita
There is growing evidence that viruses responsible for pandemics, such as Middle East respiratory syndrome and severe acute respiratory syndrome, are mainly spread through aerosols. Recommendations have been introduced to reduce the transmission risks of virulent airborne viral particles by increasing ventilation rates, expressed in air changes per hour (ACHs), effectively improving the dilution of pathogens via mechanical ventilation. However, infrastructural and operational costs associated with upgrades of building heating, ventilation, and air conditioning systems make these solutions expensive. It is well documented that Ultraviolet Subtype C (UVC) disinfection can help lower exposure risks by inactivating viruses and the performance of such solutions can translate into equivalent ventilation. Here, we present the first framework to extract the optimal UVC requirements to improve facility management yet ensuring compliance with ventilation guidelines at lower energy costs. The Kahn–Mariita (KM) model considers the air quality of shared enclosed spaces over time by supplementing the existing mechanical ventilation with localized UVC air treatment and includes variables such as room size, occupancy, existing ventilation, and target equivalent ACH. For example, the model applied to a conference room shows that a UVC chamber with recirculation rates of 160 m3/h increases ventilation from an ACH 3 to 7.9 and reduces the room’s reset time from 46 to <10 min with as little as 1 W. Recirculation rates of 30 m3/h however offer no benefits beyond 200 mW, with an eACH of 3.9 and reset time of 31 min. The first finding is that single-pass disinfection is not an appropriate metric of performance, i.e., low recirculation rates increase single-pass disinfection, and, however, only treats a portion of the space volume within a given time, limiting the overall performance. Conversely, higher recirculation rates decrease single-pass disinfection but treat larger portions of air, potentially multiple times, and are therefore expected to lower the transmission risk faster. The second result is that for fixed amounts of recirculating air flow, increasing UVC power helps with diminishing return, while for a fixed UVC power, increasing the recirculating air flow will always help. This dynamic is particularly important toward optimizing solutions, given the constraints system engineers must work with, and particularly to design for end-user benefits such as increased occupancy, in-dwelling time, or reduction of shared-space reset time.

23 March 2022 in Access Microbiology
Verified
Journal Article
Open access
Silas Onyango AwuorSilas Onyango Awuor
Silas Onyango Awuor
EOEric Omori Omwenga
Eric Omori Omwenga
RMRichard M Mariita
Richard M Mariita
IDIbrahim I. Daud
Ibrahim I. Daud
Vibrio cholerae is a biofilm-forming pathogen with various virulence phenotypes and antimicrobial resistance traits. Phenotypic characteristics play a critical role in disease transmission and pathogenesis. The current study elucidated antibiofilm formation activity, profiled antibiotic-resistant genes and virulence factors of toxigenic Vibrio cholerae isolates from the cholera outbreak in Kisumu County, Kenya. Vibrio cholerae O1 isolates collected during the 2017 cholera outbreak in Kisumu County, Kenya, were utilized. Biofilm and virulence factors were profiled using standard procedures. The study confirmed 100 isolates as Vibrio cholerae , with 81 of them possessing cholera toxin gene (ctxA). Additionally, 99 of the isolates harboured the toxR gene. The study further revealed that 81 and 94 of the isolates harboured the class I integron (encoded by inDS gene) and integrating conjugative element (ICE), respectively. Antibiotic resistance assays confirmed tetracycline resistance genes as the most abundant (97 isolates). Among them were seven isolates resistant to commonly used antibiotics. The study further screened the isolates for antibiofilm formation using various antibiotics. Unlike the four strains (03/17–16, 02/17–09, 04/17–13), three of the strains (04/17–07, 06/17–14 and 05/17–03) did not form biofilms. Further, all the seven isolates that exhibited extensive antibiotic resistance produced haemolysin while 71.42%, 85.71 and 71.42 % of them produced protease, phospholipases and lipase, respectively. This study provides and in-depth understanding of essential features that were possibly responsible for V. cholerae outbreak. Understanding of these features is critical in the development of strategies to combat future outbreaks.

12 January 2022 in Access Microbiology
Verified
Journal Article
Open access
RMRichard M Mariita
Richard M Mariita
AMAmy C. Wilson Miller
Amy C. Wilson Miller
RRRajul V. Randive
Rajul V. Randive
Human norovirus (HuNoV) is a highly contagious pathogenic virus that is transmitted through contaminated food, water, high-touch surfaces and aerosols. Globally, there are an estimated 685 million infections annually due to norovirus, including 200 million affecting children under the age of 5. HuNoV causes approximately 50, 000 child deaths per year and costs an estimated USD $60 billion annually in healthcare. This study sought to determine the inactivation profile of ultraviolet subtype C (UVC) against norovirus using a UVC light-emitting diode (LED) array, KL265-50V-SM-WD. The array emitted radiation at 269 nm peak wavelength and a measured fluence of 1.25 mW cm−2 at a 7 cm source–surface distance. Since the HuNoV is not cultivable, the study utilized feline calicivirus (FCV) ATCC VR-782, a recommended surrogate as challenge organism. The test followed modified ASTM E2197. Assessment of virus inactivation was performed using a plaque assay method. With irradiance at a UVC dose of 22.5 mJ cm−2, the study obtained 99.9 % virus reduction (3 log reduction). The results demonstrate that the UVC LED array can provide effective inactivation of HuNoV.