Human norovirus (HuNoV) is a highly contagious pathogenic virus that is transmitted through contaminated food, water, high-touch surfaces and aerosols. Globally, there are an estimated 685 million infections annually due to norovirus, including 200 million affecting children under the age of 5. HuNoV causes approximately 50, 000 child deaths per year and costs an estimated USD $60 billion annually in healthcare. This study sought to determine the inactivation profile of ultraviolet subtype C (UVC) against norovirus using a UVC light-emitting diode (LED) array, KL265-50V-SM-WD. The array emitted radiation at 269 nm peak wavelength and a measured fluence of 1.25 mW cm−2 at a 7 cm source–surface distance. Since the HuNoV is not cultivable, the study utilized feline calicivirus (FCV) ATCC VR-782, a recommended surrogate as challenge organism. The test followed modified ASTM E2197. Assessment of virus inactivation was performed using a plaque assay method. With irradiance at a UVC dose of 22.5 mJ cm−2, the study obtained 99.9 % virus reduction (3 log reduction). The results demonstrate that the UVC LED array can provide effective inactivation of HuNoV.
SARS-CoV-2 can be disinfected using ultraviolet-C (UVC) light. For effective inactivation strategies, design and implementation, knowledge of UVC wavelength sensitivity, and disinfection rate of the relevant pathogen are required. This study aimed to determine the inactivation profile of SARS-CoV-2 using UVC irradiation with different wavelengths. Specifically, the study determined dosage, inactivation levels, and wavelength sensitivity of SARS-CoV-2. Assessment of SARS-CoV-2 (isolate USA/WA1-2020) inactivation at peak wavelengths of 259, 268, 270, 275 and 280 nm was performed using a plaque assay method. A UVC dose of 3.1 mJ/cm 2 using 259 and 268 nm arrays yielded log reduction values (LRV) of 2.32 and 2.44, respectively. With a dose of 5 mJ/cm 2 , arrays of peak wavelengths at 259 and 268 nm obtained similar inactivation levels (LRV 2.97 and 2.80 respectively). The arrays of longer wavelength (270, 275 and 280 nm), demonstrated lower performances (≤LRV 2.0) when applying an irradiation dose of 5 mJ/cm 2 . Additional study with the 268 nm array revealed that a dose of 6.25 mJ/cm 2 is enough to obtain a LRV of 3. These results suggest that 259 and 268 nm are the most efficient wavelengths for SARS-CoV-2 inactivation compared to longer UVC wavelengths, allowing the calculation of disinfection systems efficacy.
Human norovirus (HuNoV) is a highly contagious pathogenic virus that is transmitted through contaminated food, water, high-touch surfaces and aerosols. Globally, there are an estimated 685 million infections annually due to norovirus, among them 200 million children under the age of 5, causing approximately 50,000 child deaths per year and costing an estimated $60 billion annually in healthcare. In the USA, HuNoV is responsible for 19-21 million illnesses, with an average of 570-800 deaths per year. HuNoV is especially pernicious because it requires less than 100 viral particles to cause an infection, and there are few effective disinfectants. It is believed that Ultraviolet Subtype C (UVC) irradiation might prove to be an effective disinfectant. This study seeks to determine the inactivation profile of UVC against norovirus using a Klaran UVC Light-emitting diode (LED) array product number KL265-50V-SM-WD, emitting radiation at 269 nm peak wavelength and a measured fluence of 1.25 mW/cm 2 at a 7 cm source-surface distance. Since the HuNoV cannot currently be propagated in cell cultures, the study utilized feline calicivirus (FCV), a recommended surrogate as challenge organism. The test followed Modified ASTM E2197. Assessment of virus inactivation was performed using plaque assay method, with Crystal Violet as a staining agent to enhance plaque visualization. Within 18 seconds of exposure time at a UVC irradiance of 1.25mW/cm 2 and a dose of 22.5 mJ/cm 2 , the study obtained 99.9 % virus reduction (3 log reduction value). These results demonstrate that Klaran UVC-LED array (KL265-50V-SM-WD) can provide effective inactivation of HuNoV.