Peng Luo

Peng Luo


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Clinical Interventions in Aging
Verified
Journal Article
Open access
PDF file
WGWei-Jun Guo
Wei-Jun Guo
JWJi-Qi Wang
Ji-Qi Wang
WZWei-Jiang Zhang
Wei-Jiang Zhang
WWWei-Kang Wang
Wei-Kang Wang
DXDing Xu
Ding Xu
PLPeng Luo
Peng Luo
Purpose: Several authors have reported the degree of total blood loss (TBL) following hemiarthroplasty for displaced femoral neck fracture; however, the research specifically investigating on hidden blood loss (HBL) after hip hemiarthroplasty is still lacking. The purpose of this study is to evaluate the HBL in patients who underwent hip hemiarthroplasty for displaced femoral neck fractures and to analyze its risk factors. Patients and methods: From January 2015 to December 2016, 212 patients (57 males and 155 females) with displaced femoral neck fracture undergoing hip hemiarthroplasty were included in this study. The demographic and relevant clinical information of the patients were collected. According to the Gross’s formula, each patient’s height, weight, and preoperative and postoperative hematocrit were recorded and used for calculating the total perioperative blood loss and HBL. Risk factors were further analyzed by multivariate linear regression. Results: The HBL was 525±217 mL, with 61.0%±13.6% in the total perioperative blood loss (859±289 mL), and the perioperative hemoglobin (Hb) loss was 23.8±7.4 g/L. Multivariate linear regression analysis revealed that HBL was positively associated with higher American Society of Anesthesiologists (ASA) classification (regression coefficient=62.169, 95% CI=15.616–108.722; P=0.009), perioperative gastrointestinal bleeding/ulcer (regression coefficient=155.589, 95% CI=38.095–273.083; P=0.010), and transfusion (regression coefficient=192.118, 95% CI=135.578–248.659; P<0.001). Compared with females, males had a risk of increased HBL (regression coefficient=87.414, 95% CI=28.547–146.280; P=0.004), and general anesthesia had an increased HBL compared with spinal anesthesia (regression coefficient=68.920, 95% CI=11.707–126.134; P=0.018). Conclusion: HBL should not be ignored in patients who underwent hip hemiarthroplasty for displaced femoral neck fractures in the perioperative period, because it is a significant portion of TBL. Female patients, patients with higher ASA classification and perioperative gastrointestinal bleeding/ulcer, patients who were administered general anesthesia, or patients who underwent transfusion had a greater amount of HBL after hip hemiarthroplasty was performed. Having a correct understanding of HBL may help surgeons improve clinical assessment capabilities and ensure patients’ safety.

15 November 2022 in Journal of Orthopaedic Translation
Verified
Journal Article
Open access
JWJia Wu
Jia Wu
HLHaoliang Li
Haoliang Li
FHFei Hu
Fei Hu
PLPeng Luo
Peng Luo
Osteoarthritis (OA) is a chronic disease that may cause articular cartilage degeneration, and synovial inflammation, resulting in considerable pain, poor quality of life, and functional limitations. Previous research has shown that ECM degradation and inflammation are involved in the progression of OA. Stevioside (STE), a naturally diterpenoid glycoside, is isolated from the Stevia rebaudiana (Bertoni), which has been exerted a variety of pharmacological activities, involving anti-inflammatory, anti-oxidative, and neuroprotective effects. However, STE's effects on OA and its mechanism still need further research. In the present study, we examined the anti-inflammatory effects of STE (STE) in both mouse chondrocytes and OA model induced by destabilization of the medial meniscus (DMM). In vitro, the mouse chondrocytes were treated with STE (0, 10, 20, 40 ​M, 24 ​h) after stimulated with IL-1β (10 ​ng/mL, 24 ​h). The expression of ant-inflammation-relative mediators iNOS and Cox-2 were detected by Western blot and RT-PCR. The catabolic factors (MMP-13, ADAMTS-4) and cartilage matrix constituent (Aggrecan, Collagen II) were measured by Western blot and Immunofluorescence staining. The Nrf2/HO-1/NF-κB signaling molecules were detected by Western blot. In vivo, histological analysis was used to evaluate the severity of mouse OA models. STE remarkably inhibited the IL-1β-induced expression of iNOS and Cox-2, generation of MMP-13, ADAMTS-4 and degradation of Aggrecan and Collagen II. Furthermore, we found that the chondroprotective effect of STE via Nrf2/HO-1/NF-κB signaling pathway. In vivo, the cartilage treated with STE displayed attenuated degeneration, low OARIS scores compared with DMM group. In conclusion, we considered that STE might be a promising therapeutic agent for the treatment of OA in future. Our findings indicated that STE can ameliorate the development of OA via inhibiting the inflammation. The underlying mechanism may be related to the Nrf2/HO-1/NF-κB signaling pathway. Moreover, the treatment of STE significantly relieves the progression in the mouse DMM model. All of the results demonstrated the therapeutic of STE in OA treatment. This study demonstrates a more efficient and safe application of STE in treating osteoarthritis, provide a new concept for the cartilage targeted application of natural compounds.

10 July 2024 in Acta Biomaterialia
Verified
Journal Article
Open access
XTXian Tong
Xian Tong
DMDaoyi Miao
Daoyi Miao
RZRunqi Zhou
Runqi Zhou
XSXinkun Shen
Xinkun Shen
PLPeng Luo
Peng Luo
XSXuecheng Sun
Xuecheng Sun
Biodegradable Zn alloys have significant application potential for hard-tissue implantation devices owing to their suitable degradation behavior and favorable biocompatibility. Nonetheless, pure Zn and its alloys in the as-cast state are mechanically instable and low in strength, which restricts their clinical applicability. Here, we report the exceptional mechanical, corrosion, and biocompatibility properties of hot-extruded Zn-5RE (wt.%, RE = rare earth of Y; or Ho; or Er) alloys intended for use in biodegradable bone substitutes. The microstructural characteristics, mechanical behavior, corrosion resistance, cytocompatibility, osteogenic differentiation, and capacity of osteogenesis in vivo of the Zn-5RE alloys are comparatively investigated. The Zn-5Y alloy demonstrates the best tensile properties, encompassing a 138 MPa tensile yield strength, a 302 MPa ultimate tensile strength, and 63% elongation, while the Zn-5Ho alloy shows the highest compression yield strength of 260 MPa and Vickers hardness of 104 HV. The Zn-5Er alloy shows a 126 MPa tensile yield strength, a 279 MPa ultimate tensile strength, 52% elongation, a 196 MPa compression yield strength, and a 101 HV Vickers microhardness. Further, the Zn-5Er alloy has a 130 µm per year corrosion rate in electrochemical tests and a 26 µm per year degradation rate in immersion tests, which is the lowest among the tested alloys. It also has the best in vitro osteogenic differentiation ability and capacity for osteogenesis and osteointegration in vivo after implantation in rat femurs among the Zn-5RE alloys, indicating promising potential in load-bearing biodegradable internal bone-fixation applications. STATEMENT OF SIGNIFICANCE: This work reports the exceptional mechanical, corrosion, and biocompatibility properties of hot-extruded (HE) Zn-5 wt.%-rare earth (Zn-5RE) alloys using single yttrium (Y), holmium (Ho), and erbium (Er) alloying for biodegradable bone-implant applications. Our findings demonstrate that the HE Zn-5Er alloy showed σuts of 279 MPa, tensile yield strength of 126 MPa, elongation of 51.6%, compression yield strength of 196 MPa, and microhardness of 101.2 HV. Further, HE Zn-5Er showed the lowest electrochemical corrosion rate of 130 µm/y and lowest degradation rate of 26 µm/y, and the highest in vitro osteogenic differentiation ability, in vivo osteogenesis, and osteointegration ability after implantation in rat femurs among the Zn-5RE alloys, indicating promising potential in load-bearing biodegradable internal bone-fixation applications.

1 February 2019 in Injury
Verified
Journal Article
Closed access
JWJi-Qi Wang
Ji-Qi Wang
ZCZe-Xin Chen
Ze-Xin Chen
WGWei-Jun Guo
Wei-Jun Guo
YZYou-Ming Zhao
You-Ming Zhao
PLPeng Luo
Peng Luo

1 December 2017 in Medicine
Verified
Journal Article
Open access
PDF file
PLPeng Luo
Peng Luo
DXDing Xu
Ding Xu
JWJia Wu
Jia Wu
YCYi-Heng Chen
Yi-Heng Chen
This article is a systematic review of the published literature about the biomechanics, functional outcomes, and complications of a locked plate as an external fixator in treating tibial fractures. We searched the PubMed, Ovid Medline, Embase, ScienceDirect, and Cochrane Library databases to retrieve the relevant studies. Studies published in English and Chinese which assessed adult patients and more than 4 cases who had sustained any type of fresh tibial fracture treated with the external locking plate, provided that they reported functional outcomes, range of motion (ROM), union or complication rates, and the biomechanical studies of external locked plating are also included. The electronic search strategy revealed 248 studies, and 2 studies were identified as relevant through manual search of references. Finally, 12 studies were included in this systematic review. These consist of 3 pure biomechanical studies, 8 case series, and 1 study including both of biomechanics and case series. Due to the heterogeneity of biomechanical studies, we can only conclude that external locked plate shows inferior structural stiffness than internal locked plate. The clinical studies reported that external locked plating gave a satisfactory ROM of the knee and ankle, functional outcomes, union rate, and low complication rate. We can only conclude that external locked plate shows inferior structural stiffness than internal locked plate because of the heterogeneity of biomechanical studies. The clinical studies showed locked plating as an external fixator in treating tibial fractures can be considered as a safe and successful procedure. However, as yet, there is unconvincing evidence that it is superior to standard techniques with regards to clinical and functional outcomes. More and well-designed studies about this technique should be carried out.

19 March 2020 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
ZTZhengbo Tao
Zhengbo Tao
WLWenbo Liu
Wenbo Liu
WMWeifeng Ma
Weifeng Ma
PLPeng Luo
Peng Luo
SZShengpeng Zhi
Shengpeng Zhi
RZRenyi Zhou
Renyi Zhou
Background: The incidence of rupture of the quadriceps or patellar tendon s is low, especially that of bilateral quadriceps tendon rupture, and it is generally considered a complication secondary to chronic systemic disorders. We report two rare cases of simultaneous bilateral tendon rupture affecting the extensor function of the knee in patients with chronic kidney disease who have been treated with long-term haemodialysis. Case presentation: Two young males with a history of chronic kidney disease who were being treated with long-term haemodialysis presented to our hospital with clinical signs of disruption of the extensor mechanism of the knee. One patient was diagnosed with bilateral quadriceps tendon rupture, and the other patient had bilateral patellar tendon rupture. They underwent surgical repair of the tendons, and their knees were actively mobilized during physiotherapy. Conclusion: Bilateral quadriceps or patellar tendons rupture is a rare occurrence in patients with chronic kidney disease who are being treated with long-term haemodialysis. Timely surgical treatment and scientific physiotherapy can lead to good recovery of knee joint function.