Paul Diego

Mr. Paul Diego

PhD Student at the Faculty of Engineering in Bilbao (UPV/EHU)

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 May 2021 in Materials
Verified
Journal Article
Open access
PDF file
HAHegoi Amestoy
Hegoi Amestoy
PDPaul Diego
Paul Diego
Emilio MeaurioEmilio Meaurio
Emilio Meaurio
jone muñozjone muñoz
jone muñoz
Jose-Ramon SarasuaJose-Ramon Sarasua
Jose-Ramon Sarasua
Poly(ε-caprolactone) (PCL) was mixed with submicron particles of barium sulfate to obtain biodegradable radiopaque composites. X-ray images comparing with aluminum samples show that 15 wt.% barium sulfate (BaSO4) is sufficient to present radiopacity. Thermal studies by differential scanning calorimetry (DSC) show a statistically significant increase in PCL degree of crystallinity from 46% to 52% for 25 wt.% BaSO4. Non-isothermal crystallization tests were performed at different cooling rates to evaluate crystallization kinetics. The nucleation effect of BaSO4 was found to change the morphology and quantity of the primary crystals of PCL, which was also corroborated by the use of a polarized light optical microscope (PLOM). These results fit well with Avrami–Ozawa–Jeziorny model and show a secondary crystallization that contributes to an increase in crystal fraction with internal structure reorganization. The addition of barium sulfate particles in composite formulations with PCL improves stiffness but not strength for all compositions due to possible cavitation effects induced by debonding of reinforcement interphase.

14 May 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PDPaul Diego
Paul Diego
SVSaioa Herrero Villalibre
Saioa Herrero Villalibre
EMErik Macho
Erik Macho
Javier CorralJavier Corral
Javier Corral
MDMikel Diez
Mikel Diez
CPCharles Pinto
Charles Pinto
Gait and balance have a direct impact on patients’ independence and quality of life. Due to a higher life expectancy, the number of patients suffering neurological disorders has increased exponentially, with gait and balance impairments being the main side effects. In this context, the use of rehabilitation robotic devices arises as an effective and complementary tool to recover gait and balance functions. Among rehabilitation devices, end effectors present some advantages and have shown encouraging outcomes. The objective of this study is twofold: to propose a general classification of devices for gait and balance rehabilitation and to provide a review of the existing end effectors for such purposes. We classified the devices into five groups: treadmills, exoskeletons, patient-guided systems, perturbation platforms, and end effectors. Overall, 55 end effectors were identified in the literature, of which 16 were commercialized. We found a disproportionate number of end effectors capable of providing both types of rehabilitation (2/55) and those focused on either balance (21/55) or gait (32/55). The analysis of their features from a mechanical standpoint (degrees of freedom, topology, and training mode) allowed us to identify the potential of parallel manipulators as driving mechanisms of end effector devices and to suggest several future research directions.

17 October 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PDPaul Diego
Paul Diego
EMErik Macho
Erik Macho
SVSaioa Herrero Villalibre
Saioa Herrero Villalibre
FCFrancisco J. Campa
Francisco J. Campa
MDMikel Diez
Mikel Diez
CPCharles Pinto
Charles Pinto
This paper presents a novel parallel manipulator capable of generating two translations (2T), inside a vertical plane, and two rotations (2R), about horizontal axes, which are required in aerospace, manufacturing and rehabilitation fields. These four degrees of freedom are reached by means of a unique RRU and three RSS kinematic chains connected to a rhomboid-shaped mobile platform. The kinematic analysis of the new manipulator is provided, which includes the resolution of the inverse position problem and the velocity equations relating to input and output variables. Additionally, a methodology is proposed for obtaining the workspace free of singularities, collisions and kinematic joint range limitation. This systematic methodology allows designers to identify the critical factors affecting the workspace and, thus, to rearrange the mechanical design accordingly for optimum path planning. We represent the workspace using its two-dimensional subspaces (i.e., translational and rotational workspace). The results are analyzed for different working modes of the manipulator to see its potential use in applications wherein 2T2R motion is necessary.

4 August 2025 in Sensors
Verified
Journal Article
Open access
PDF file
ACAdrián Schmedling Casas
Adrián Schmedling Casas
EMErik Macho
Erik Macho
FCFrancisco J. Campa
Francisco J. Campa
RMRuben Valenzuela Montes
Ruben Valenzuela Montes
MDMikel Diez
Mikel Diez
CPCharles Pinto
Charles Pinto
In the study of biomechanical models, balance represents a complex problem due to the issue of indeterminate forces while standing. In order to solve this problem, it is essential to measure the ground reaction forces (GRFs) applied to each foot independently. The present work proposes a methodology for determining the independent GRF applied to each foot while standing when only one forceplate is available. For this purpose, an analytical method is proposed to determine the distribution of vertical GRFs and the position of the independent center of pressure (CoP) in each foot. Concurrently, several neural network (NN) models are trained to improve the results obtained. This hypothesis is experimentally validated by a self-developed device that allows one to simultaneously obtain the vertical GRF and CoP location of each foot at the same time that the GRF and the global CoP location are obtained from a single forceplate. The results obtained achieve a CoP position error of less than 8% and a vertical force error of 2%. The analytical hypothesis is demonstrated to offer a satisfactory level of precision, while the NN is shown to result in considerable improvement in some cases.

22 December 2025 in Mechanism and Machine Theory
Verified
Journal Article
Open access
PDPaul Diego
Paul Diego
EMErik Macho
Erik Macho
FCFrancisco J. Campa
Francisco J. Campa
SVSaioa Herrero Villalibre
Saioa Herrero Villalibre
MDMikel Diez
Mikel Diez
CPCharles Pinto
Charles Pinto

5 November 2023
Verified
Book Chapter
Closed access
PDF file
PDPaul Diego
Paul Diego
EMErik Macho
Erik Macho
SVSaioa Herrero Villalibre
Saioa Herrero Villalibre
Javier CorralJavier Corral
Javier Corral
MDMikel Diez
Mikel Diez
CPCharles Pinto
Charles Pinto