Midwave infrared interband-cascade light-emitting devices (ICLEDs) have the potential to improve the selectivity, stability, and sensitivity of low-cost gas sensors. We demonstrate a broadband direct absorption CH4 sensor with an ICLED coupled to a plastic hollow-core fiber (1 m length, 1500 µm inner diameter). The sensor achieves a 1σ noise equivalent absorption of approximately 0.2 ppmv CH4 at 1 Hz, while operating at a low drive power of 0.5 mW. A low-cost sub-ppmv CH4 sensor would make monitoring emissions more affordable and more accessible for many relevant industries, such as the petroleum, agriculture, and waste industries.
Population growth and urbanization are driving the demand for centralized wastewater treatment, a primary source of N2O and CH4 emissions. We have conducted the first comprehensive assessment of CH4, N2O and NH3 emissions across diurnal, day-to-day and seasonal scales at 96 US water resource recovery facilities (WRRFs) that collectively treat 9% of US centralized wastewater. Facility-level emissions were scaled to the national level using a probabilistic approach. Here we show that the measured emissions were 1.9 times higher for N2O (95% confidence interval (CI): 1.3–2.6) and 2.4 times higher for CH4 (CI: 1.9–2.9) than current US inventories. Considering the cumulative climate impacts of CH4 and N2O, the top 10% of emitters contributed 74% of the carbon footprint, with the top half contributing 98%, highlighting priorities for mitigation. Although detected at only a small fraction of facilities, measurements of NH3 emissions (86 kt yr−1 in the USA) suggest WRRFs are an overlooked source of urban NH3. Finally, the contribution of centralized wastewater treatment to global greenhouse gas emissions will increase 2- to 17-fold by 2100 under future scenarios. Overall, greater consideration of wastewater treatment emissions is needed to reach sustainability targets.
20 August 2021 in Atmospheric Measurement Techniques
We report on applications of the ultraviolet-light-emitting-diode-based incoherent broadband cavity-enhanced absorption spectroscopy (UV-LED-IBBCEAS) technique for optical monitoring of HONO, NO2 and CH2O in a simulation chamber. Performance intercomparison of UV-LED-IBBCEAS with a wet chemistry-based NitroMAC sensor and a Fourier transform infrared (FTIR) spectrometer has been carried out on real-time simultaneous measurement of HONO, NO2 and CH2O concentrations during the reaction of NO2 with H2O vapour in CESAM (French acronym for Experimental Multiphasic Atmospheric Simulation Chamber). The 1σ (signal-to-noise ratio (SNR) = 1) detection limits of 112 pptv for NO2, 56 pptv for HONO and 41 ppbv for CH2O over 120 s were found for the UV-LED-IBBCEAS measurement. On the contrary to many set-ups where cavities are installed outside the simulation chamber, we describe here an original in situ permanent installation. The intercomparison results demonstrate that IBBCEAS is a very well suitable technique for in situ simultaneous measurements of multiple chemically reactive species with high sensitivity and high precision even if the absorption bands of these species are overlapped. It offers excellent capacity for non-invasive optical monitoring of chemical reactions without any perturbation. For the application to simulation chambers, it has the advantage to provide a spatially integrated measurement across the reactor and hence to avoid point-sampling-related artefacts.
A spectroscopic instrument based on a mid-infrared external cavity quantum cascade laser was developed for high-accuracy measurements of N2O5 at the ppbv-level.