Martina  Rafanelli

Dr. Martina Rafanelli


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2015 in EP Europace
Verified
Journal Article
Open access
PDF file
MBMichele Brignole
Michele Brignole
FAFrancesco Arabia
Francesco Arabia
FAFabrizio Ammirati
Fabrizio Ammirati
MTMarco Tomaino
Marco Tomaino
FQFabio Quartieri
Fabio Quartieri
SISyncope Unit Project 2 (SUP 2) investigators
Syncope Unit Project 2 (SUP 2) investigators
The aim of this study was to determine the long-term effects and determinants of success of cardiac pacing in patients affected by reflex syncope enrolled in the Syncope Unit Project 2 (SUP 2) study. Initial results have validated the effectiveness of a standardized guideline-based algorithm which can be used in clinical practice in order to select suitable candidates for cardiac pacing. In this prospective, multicentre, observational study, patients aged >40 years, affected by severe unpredictable recurrent reflex syncope, underwent carotid sinus massage (CSM), followed by tilt testing (TT) if CSM was negative, followed by implantation of an implantable loop recorder (ILR) if TT was negative. Those who had an asystolic response to one of these tests received a dual-chamber pacemaker. Of 281 patients who met the inclusion criteria, 137 (49%) received a pacemaker and were followed up for a mean of 26 ± 11 months: syncope recurred in 25 (18%) of them. At 3 years, the actuarial syncope recurrence rate was 20% [95% confidence interval (CI) 12–30] and was significantly lower than in 142 patients who did not receive a pacemaker and were observed by means of an ILR [43% (95% CI 29–57), P = 0.01]. The 3-year recurrence rate was not different among 78 CSM+, 38 TT+, and 21 ILR+ patients, whereas it was lower in 20 patients with negative TT [5% (95% CI 0–15)] than in 61 patients with positive TT [24% (95% CI 10–38)]. The benefit of cardiac pacing is maintained at 3 years, irrespective of the index diagnostic test, and is maximum in patients with negative TT. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01509534.

28 June 2016 in Journal of the American Geriatrics Society
Verified
Journal Article
Closed access
PDF file
AUAndrea Ungar
Andrea Ungar
CMChiara Mussi
Chiara Mussi
ACAlice Ceccofiglio
Alice Ceccofiglio
GBGiuseppe Bellelli
Giuseppe Bellelli
FNFranco Nicosia
Franco Nicosia
PAPasquale Abete
Pasquale Abete

30 August 2013 in Aging Clinical and Experimental Research
Verified
Journal Article
Closed access
PDF file
MRMartina Rafanelli
Martina Rafanelli
ERE. Ruffolo
E. Ruffolo
VCV. M. Chisciotti
V. M. Chisciotti
MBM. A. Brunetti
M. A. Brunetti
ACA. Ceccofiglio
A. Ceccofiglio
AUAndrea Ungar
Andrea Ungar

14 May 2015 in EP Europace
Verified
Journal Article
Closed access
PDF file
AUAndrea Ungar
Andrea Ungar
FTFrancesca Tesi
Francesca Tesi
VCValentina Maddalena Chisciotti
Valentina Maddalena Chisciotti
GPGiuseppe Pepe
Giuseppe Pepe
SVSimone Vanni
Simone Vanni
MBMichele Brignole
Michele Brignole
Aims High hospitalization rates (39–58% in the literature) of patients admitted to Emergency Department (ED) for transient loss of consciousness (T-LOC) suspected for syncope are still an unresolved issue. The presence of an Observation Unit has reduced hospital admissions and the duration of hospitalization in controlled studies, and a Syncope Unit (SU) in the hospital may reduce hospitalization and increase the number of diagnoses in patients with T-LOC. We assessed the effect of a structured organization on hospitalization rate and outcome. Methods and results Consecutive patients referred to the ED for a T-LOC of a suspected syncopal nature as the main diagnosis were included. The ED physician was trained to choose between: hospital admission (directly or after short observation); discharge after short (<48-h) observation; discharge on a fast track to the SU; and direct discharge without any further diagnostics. From January to June 2010, 362 patients were evaluated in the ED: 29% were admitted, 20% underwent short observation in the ED, 20% were referred to the SU, and 31% were directly discharged. Follow-up data were available on 295 patients who were discharged alive: of these, 1 (0.3%) previously hospitalized patient died within 30 days and 16 (5.4%) died within 1 year. Death rates were 12.9, 3.3, 0, and 2.5% among admitted, observation, SU, and ED-discharged patients, respectively. No death could be directly attributed to T-LOC. Re-admission within 1 year for any cause occurred in 72 (24%) patients; re-admission rates were 45.9, 19.3, 11.5, and 18.0% among admitted, observation, SU, and ED-discharged patients, respectively. Conclusions The availability of short observation and a SU seems to reduce the hospitalization rate compared with previous reported historical reports from our and other centres. Most deaths during follow-up occurred in patients who had been hospitalized. High rates of re-admission to the ED within 1 year are still an issue.

31 January 2016 in Age and Ageing
Verified
Journal Article
Open access
PDF file
AUAndrea Ungar
Andrea Ungar
GRGiulia Rivasi
Giulia Rivasi
MRMartina Rafanelli
Martina Rafanelli
GTGiulia Toffanello
Giulia Toffanello
CMChiara Mussi
Chiara Mussi
RKRose Anne Kenny
Rose Anne Kenny
Objective: to evaluate the safety and tolerability of Tilt Testing (TT) and Carotid Sinus Massage (CSM) in octogenarians with unexplained syncope.

25 March 2014 in EP Europace
Verified
Journal Article
Open access
PDF file
RMRoberto Maggi
Roberto Maggi
MRMartina Rafanelli
Martina Rafanelli
ACAlice Ceccofiglio
Alice Ceccofiglio
DSDiana Solari
Diana Solari
MBMichele Brignole
Michele Brignole
AUAndrea Ungar
Andrea Ungar
Non-syncopal transient loss of consciousness (T-LOC) encompasses disorders that sometimes resemble syncope, and the differential diagnosis with true syncope may be challenging. The implantable loop recorder (ILR) is potentially useful, but has never been systematically assessed. The aim of the study is to evaluate the diagnostic value of ILR in distinguishing syncope from non-syncopal forms of T-LOC. We implanted an ILR in 58 patients (mean age 71 ± 17 years, 25 males) who had had 4.6 ± 2.3 episodes of real or apparent T-LOC, in order to distinguishing epilepsy from syncope (#28), unexplained fall from syncope (#29), or functional pseudo-syncope from syncope (#1). During 20 ± 13 months of follow-up, 33 patients (57%) had a spontaneous event documented by ILR. A diagnosis of syncope was established by ILR documentation of an arrhythmia in 15 (26%) patients: an asystole of 6 s (IQR 4–10 s) duration was documented at the time of the spontaneous event in seven patients with initial suspicion of epilepsy and in five patients with unexplained fall; atrial tachyarrhythmia was documented at the time of the spontaneous event in 1 and 1 patient, respectively, and ventricular tachycardia in 1 patient with unexplained fall. Conversely, in another 18 patients, ILR monitoring documented no significant rhythm abnormalities at the time of T-LOC recurrence, thus excluding an arrhythmic syncope. Finally, ILR was unable to document any syncopal episode in 25 (43%) patients. Among the 15 patients with an established diagnosis of arrhythmic syncope, syncope recurred during follow-up in 2 of 11 patients who were on pacemaker therapy and in 3 of 4 patients who were on other therapies. Implantable loop recorder monitoring provides additional diagnostic value in ‘difficult’ patients with an initial diagnosis of non-syncopal real or apparent T-LOC.