To determine the effect of isotretinoin on corneal sensitivity in acne patients. Fifty patients (13 men and 37 women) with a mean age of 23.24 ± 3.4 years were selected among patients receiving isotretinoin (1.0 mg/kg) for acne according to inclusion criteria. The Cochet-Bonnet esthesiometer was used to measure corneal sensitivity (in mm filament length) two times (the measurements were done immediately before starting the medication, then 3 months after that), including 3 measurements each time, between 11 a.m. and 1 p.m. by an experienced operator. The average of the 3 measurements in each time was recorded as the final value. One-way analysis of variance and Chi square were used for quantitative and qualitative comparison of corneal sensitivity before and after isotretinoin use, respectively. The mean corneal sensitivity was 5.54 ± 0.05 before medication consumption which decreased to 5.41 ± 0.05 after isotretinoin treatment for 3 months (P < 0.005). After controlling the effect of age and sex, the decrease of corneal sensitivity was markedly significant (P = 0.003) as decreased corneal sensitivity was more pronounced at higher ages and in female gender. In non-parametric evaluation, corneal sensitivity was categorized as substantial (5.5-6 mm), intermediate (4.5-5.5 mm), and low (3.5-4.5). About 72% of the participants had substantial corneal sensitivity before drug consumption, which decreased to 60% after 3 months of treatment. According to the results of this study, corneal sensitivity decreases after three months of treatment with isotretinoin. This decrease is more pronounced at higher ages and in women.
1 January 2015 in Journal of Ophthalmic and Vision Research
To determine the short-term effect of rigid gas permeable (RGP) contact lenses on corneal aberrations in keratoconic patients. Sixteen keratoconic eyes with no history of RGP lens wear were included. They all had corneal aberrometry using Pentacam, and different aberration indices of the anterior and posterior surfaces of the cornea were measured before and 3 months after fitting RGP lenses. The effect of baseline parameters on these changes was tested in univariate and multiple models. Total aberrations and individual Zernike coefficients did not show statistically significant changes after using RGP lenses. Although not statistically significant, vertical coma decreased in the anterior (p = 0.073) and posterior surface (p = 0.095). Relationships that remained statistically significant in the multiple model were between baseline central corneal thickness and changes in total higher order aberrations and anterior 4th order astigmatism 0°, and between baseline 2nd order astigmatism 45° and its changes. In this study, corneal aberrations remained unchanged 3 months after wearing RGP contact lens. Further studies with sufficient samples in different groups of keratoconus severity or baseline aberrations are needed to obtain more accurate results.
Purpose: To evaluate the diagnostic value of visual evoked potentials (VEPs) and to find out which test setting has the most sensitivity and specificity for amblyopia diagnosis. Methods: Thirty-three adult anisometropic amblyopes were intended in this study and were tested for visual evoked potentials with different stimulus conditions including three spatial frequencies [1, 2, and 4-cycles-per-degree (cpd)] at four contrast levels (100, 50, 25, and 5%). We also tested psychophysical contrast sensitivity and compared the results with electrophysiological ones. We plotted Receiver Operating Characteristic (ROC) curve for each VEP recording and psychophysical contrast sensitivity to evaluate the area under the curve, sensitivity, specificity, and cut-point value of each test stimulus for detecting amblyopic eyes. Results: Thirty-three amblyopic and 33 non-amblyopic eyes were examined for psychophysical contrast sensitivity and VEPs. Area under the ROC curve (AURC) findings showed that VEP with different stimulus settings can significantly detect amblyopic eyes, as well as psychophysical contrast sensitivity test. We found that P100 amplitudes had the largest AURC in response to stimuli of 2-cpd spatial frequency at 50 (P < 0.001) and 25% (P < 0.001) contrast levels, respectively. Cut-off amplitudes for these stimuli were 8.65 and 4.50 mu V, which had a sensitivity of 0.758 and 0.697 and a specificity of 0.788 and 0.848, respectively. The sensitivity and specificity of VEP P100 amplitude in response to the stimuli with 2 cpd spatial frequency and 50 and 25% contrast were greater than the findings obtained from psychophysical contrast sensitivity test. Conclusion: According to our findings, assessment of VEP amplitudes in response to stimuli of 2-cpd spatial frequency at 50 and 25% contrast levels can best detect amblyopia with highest sensitivity and specificity and thus, are the protocols of choice for detection of amblyopic eyes. Copyright (C) 2018, Iranian Society of Ophthalmology. Production and hosting by Elsevier B.V.
1 September 2019 in Journal of Current Ophthalmology
Purpose: To determine the agreement of table-mounted and handheld auto-refractometers and to evaluate the effect of age and different types of refractive errors on this comparison. Methods: In this cross-sectional study conducted in 2015 using multi-stage cluster sampling, two underserved villages were selected randomly in the north and southwest of Iran. All the selected participants underwent optometric and ophthalmic examinations. Refraction was measured using handheld and table-mounted auto-refractometers in 652 subjects. Results: The mean age of the subjects was 32.7 +/- 18.72 years, and 58.3% of them were female. A significant difference was observed in the results of sphere, spherical equivalent (SE), and J45 vector between the two devices (P < 0.012), but there was no significant difference in J0 vector. There was a significant difference in the results of sphere between the two devices in all age groups under 50 years (P = 0.005), but there was no difference in age groups above 50 years. Correlation coefficients of the two devices were 0.989, 0.986, 0.908, and 0.951 for the results of sphere, SE, J0 vector, and J45 vector, respectively (P < 0.0001). The 95% limit of agreement (LOA) of the two devices was -0.31 to +0.53 for sphere, -0.27 to +0.63 for SE, -0.27 to +0.27 for J0 vector, and -0.16 to -0.17 for J45 vector. Conclusions: According to our findings, the spherical error and cylindrical power measurements of the two devices have a significant correlation. Although there is a significant difference in the mean values between the two devices, this difference may be considered clinically insignificant, and considering the narrow 95% LOA between the two devices, the results may be used interchangeably. Copyright (C) 2018, Iranian Society of Ophthalmology. Production and hosting by Elsevier B.V.
Purpose: The aim of this study is to evaluate the effect of active vision therapy in adults with anisometropic amblyopia. Methods: In this study, 20 adults with anisometropic amblyopia aged from 17-35 years old were treated for five sessions (one session per week) with vision therapy techniques which include accommodative rock, vergence rock, and saccadic training. Moreover, computerized vision therapy was performed by Optosys (R) software. Also, patients had been given a daily program for home training, including accommodative and vergence rock, and Optosys (R) software. Best corrected visual acuity (BCVA) was measured before and after treatment. Results: Comparison of data using t-test showed that BCVA significantly improved after the vision therapy period. Initial BCVA (Log MAR) was 0.37 +/- 0.04 (mean +/- standard deviation) which improved to 0.14 +/- 0.03 after treatment. The correlation between initial BCVA and the amount of improvement showed that the worse the pre-treatment visual acuity was, the greater improvement that occurred. Conclusion: The improvement of visual acuity in adult anisometropic amblyopes showed that there are some degrees of plasticity in the visual system of amblyopic patients even in adulthood. Thus, therapists should give the chance of treatment to adult amblyopes.