Zhiyi Liu

Mr. Zhiyi Liu


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2012 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
LLLe Liu
Le Liu
XCXiangliang Chen
Xiangliang Chen
ZLZhiyi Liu
Zhiyi Liu
SMSuihua Ma
Suihua Ma
CDChan Du
Chan Du
JGJihua Guo
Jihua Guo

1 May 2010 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
ZLZhiyi Liu
Zhiyi Liu
YHYonghong He
Yonghong He
LLLe Liu
Le Liu
SMSuihua Ma
Suihua Ma
XCXinyuan Chong
Xinyuan Chong
JGJihua Guo
Jihua Guo

25 October 2011 in Sensors
Verified
Journal Article
Open access
PDF file
ZLZhiyi Liu
Zhiyi Liu
HSHeng Shi
Heng Shi
LLLe Liu
Le Liu
SDSunan Deng
Sunan Deng
YJYanhong Ji
Yanhong Ji
YHYonghong He
Yonghong He
Conventional fluorescence scanners utilize multiple filters to distinguish different fluorescent labels, and problems arise because of this filter-based mechanism. In this work we propose a line-monitoring, hyperspectral fluorescence technique which is designed and optimized for applications in multi-channel microfluidic systems. In contrast to the filter-based mechanism, which only records fluorescent intensities, the hyperspectral technique records the full spectrum for every point on the sample plane. Multivariate data exploitation is then applied to spectra analysis to determine ratios of different fluorescent labels and eliminate unwanted artifacts. This sensor is designed to monitor multiple fluidic channels simultaneously, providing the potential for multi-analyte biosensing. The detection sensitivity is approximately 0.81 fluors/μm2, and this sensor is proved to act with a good homogeneity. Finally, a model experiment of detecting short oligonucleotides has demonstrated the biomedical application of this hyperspectral fluorescence biosensor.

12 February 2009
Verified
Conference Paper
Closed access
SMSuihua Ma
Suihua Ma
LLLe Liu
Le Liu
ZZZhong Zhang
Zhong Zhang
YHYonghong He
Yonghong He
ZLZhiyi Liu
Zhiyi Liu
ZWZhanshan Wang
Zhanshan Wang
In a SPR sensor, a glass slide is coated with a metal film, whose thicknesses, density and dielectric constant deadly affect the measurement sensitivity and precision in bio-detection. The optimum thickness of gold film used in SPR is between 40nm and 50nm without adhesive film, according to calculations based on multilayer reflection model cited in large numbers of literatures. But experimental study on the optimum film parameters are still lacking attribute to the limitation of film coating technology and high-precision thickness measurement technology. The optimum gold film thickness is not 45nm observed in our SPR bio-detection, and the property of adhesive film which is needed for enhancing the adhesion of metal film affects the SPR responsive bandwidth and minimum reflectivity. The experiment study on the sensor gold film and the property of adhesive film for SPR sensor are described in this paper using high precision SPR detection system, X-ray diffraction and magnetron sputtering technology. The optimum thickness for single gold film is 44nm and is 42nm for gold film with 2.4nm Cr adhesive layer. A new estimating factor is proposed to evaluate the quality and resolution of metallic film.

1 January 2012 in Chinese Optics Letters
Verified
Journal Article
Closed access
XCXiangliang Chen Xiangliang Chen
Xiangliang Chen Xiangliang Chen
LLLe Liu Le Liu
Le Liu Le Liu
ZLZhiyi Liu
Zhiyi Liu
HSHeng Shi Heng Shi
Heng Shi Heng Shi
SMSuihua Ma Suihua Ma
Suihua Ma Suihua Ma
JGJihua Guo Jihua Guo
Jihua Guo Jihua Guo
We propose a surface plasmon resonance (SPR) sensor based on phase modulation and polarization interferometry, both of which provide a refractive index (RI) resolution of the same order as that of SPR sensors of the phase type. And it has a wide dynamic range and insensitivity of RI resolution to the thickness of metal films as that of the intensity type SPR sensors. In this letter, we choose electro-optic (EO) phase modulation instead of the angle modulation. We demonstrate theoretically that with the EO phase modulation, our sensor could provide a better RI resolution.

24 August 2009
Verified
Conference Paper
Closed access
LLLe Liu
Le Liu
CZChongwen Zhang
Chongwen Zhang
ZLZhiyi Liu
Zhiyi Liu
XCXinyuan Chong
Xinyuan Chong
SMSuihua Ma
Suihua Ma
JGJihua Guo
Jihua Guo
Surface plasmon resonance (SPR) is an optical label-free sensing technique with high sensitivity and has been widely used in biological and chemical studies. Recently, there are many reports about sensing DNA microarrays with two-dimensional surface plasmon resonance imaging (SPRi) technique. However, the relations between the SPR refractive index response and the conditions of DNA immobilization are still not well known. This impedes the development of SPR bio-sensing. In this paper, we use a SPR imaging technique which we have previously reported-parallel scan spectral SPR imaging-to study the equivalent refractive index of the DNA probes (Bacterial 16S rDNA universal primer) immobilized on gold surface of the SPR sensing module. We change the immobilization conditions including types of the buffer solution, the incubation time and the concentrations of probe, obtain the equivalent refractive index of these biochemical molecules on the gold surface. From the relations of the equivalent refractive index and these conditions, we finally conclude with the optimal conditions of the DNA immobilization. These results are useful for further DNA microarray studies base on SPR.