Within the current SARS-CoV-2 pandemic, personal protective equipment, including face masks, is one important tool to interrupt virus transmission chains within the community. In this context, the quality of different face masks is frequently discussed and should, therefore, be evaluated. In this study, nanofleece textiles with a particle filtering effect and textiles with a self-disinfecting treatment were examined, which may be combined in face masks. Firstly, newly developed nanofleece textiles were tested regarding their filtration efficiency against airborne coronavirus, using feline coronavirus (FCoV) as a surrogate for SARS-CoV-2. The tested nanofleece textiles showed filtration efficiencies of over 95% against FCoV when used as a double layer and were, therefore, almost on par with the FFP-2 mask material, which was used as a reference. Secondly, eight treated, self-disinfecting textiles, which may increase the safety in the handling of potentially contaminated masks, were tested against SARS-CoV-2. Three out of eight treated textiles showed significant activity against SARS-CoV-2 and achieved about three LOG10 (99.9%) of virus titer reduction after twelve hours of incubation. Since all possible transmission paths of SARS-CoV-2, as well as the minimal infection doses, remain unknown, both investigated approaches seem to be useful tools to lower the virus spread within the community.
Enveloped respiratory viruses, including the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), can be transmitted through aerosols and contact with contaminated surfaces. The stability of these viruses outside the host significantly impacts their transmission dynamics and the spread of diseases. In this study, we investigated the tenacity of Feline Coronavirus (FCoV) in aerosols and on surfaces under varying environmental conditions. We found that airborne FCoV showed different stability depending on relative humidity (RH), with higher stability observed at low and high RH. Medium RH conditions (50–60%) were associated with increased loss of infectivity. Furthermore, FCoV remained infectious in the airborne state over 7 h. On stainless-steel surfaces, FCoV remained infectious for several months, with stability influenced by organic material and temperature. The presence of yeast extract and a temperature of 4 °C resulted in the longest maintenance of infectivity, with a 5 log10 reduction of the initial concentration after 167 days. At 20 °C, this reduction was achieved after 19 days. These findings highlight the potential risk of aerosol and contact transmission of respiratory viruses, especially in enclosed environments, over extended periods. Studying surrogate viruses like FCoV provides important insights into the behavior of zoonotic viruses like SARS-CoV-2 in the environment.
The COVID-19 pandemic has highlighted the risk of airborne transmission of viruses, especially in public indoor spaces or healthcare settings. Effective indoor air purification systems are necessary to limit the spread of these pathogens, and the deployment of portable air cleaners (PACs) has increased rapidly since then. Germicidal ultraviolet (UV) radiation technologies have recently supplemented conventional air filtration technologies. Thus, the purpose of this study was to evaluate the air decontamination efficacy of a PAC using a 275-nm UVC-LED unit and fibrous-media air filters. Two different filters were used in the study: a High-Efficiency Particulate Air (HEPA) filter and an Efficient Particulate Air (EPA) filter. The PAC was operated in an experimental aerosol chamber with an airflow rate of 200 m³/hour for 10 or 20 minutes. Subsequently, the concentration of infectious viruses and particles in the air was measured. Decontamination efficacy was compared between UVC-LED radiation, filtration, and a combination thereof against Feline Coronavirus (FCoV) and influenza A virus (H3N2) aerosols. Infectious virus reductions were comparable between the UVC and filter measurements. A decrease of 94% in FCoV concentration was observed after 10 minutes of device runtime, increasing to 99.8% after 20 minutes compared to control measurements. H3N2 showed greater susceptibility, with a reduction of 99.7% achieved after 10 minutes. Interestingly, a synergistic effect was observed with significantly lower virus concentrations when both technologies were combined. These findings highlight the potential of PACs equipped with emerging UVC-LED technologies as effective tools for indoor air decontamination. The deployment of PACs equipped with UVC radiation and filtration could be a promising alternative or supplement to ventilation systems, especially in healthcare settings and other public spaces.