Moritz Friedrich Lodde

Dr. Moritz Friedrich Lodde

University hospital Münster
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2021 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
MLMoritz Friedrich Lodde
Moritz Friedrich Lodde
MRM. J. Raschke
M. J. Raschke
JSJ. Stolberg-Stolberg
J. Stolberg-Stolberg
JEJ. Everding
J. Everding
SRS. Rosslenbroich
S. Rosslenbroich
JKJ. C. Katthagen
J. C. Katthagen
Background: The optimal treatment strategy for the surgical management of femur fractures and non-unions remains unknown. The aim of this study is to assess union rates, complications and outcome after femoral double plating. Treatment of shaft, distal, periprosthetic fractures and pathological proximal femur fractures as well as femoral non-unions with double plating were evaluated.Methods: A systematic review according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) statement was conducted. Published literature reporting on the treatment and clinical outcome of femoral fractures and non-unions with double plating was identified. In total, 24 studies with 436 cases of double plating, 64 cases of single plating, 84 cases of intramedullary nailing (IM), and 1 interfragmentary screw treatment met the inclusion criteria of this systematic review. The evaluated literature was published between 1991 and 2020.Results: Double plating of femoral fractures achieved high healing rates and few complications were reported. It displayed significantly less intraoperative haemorrhage, shorter surgery time reduced risk of malunion in polytraumatised patients when compared to IM. Fracture healing rate of double-plating distal femoral fractures was 88.0%. However, there were no significant differences regarding fracture healing, complication or functional outcome when compared to single plating. Treatment of periprosthetic fractures with double plating displayed high healing rates (88.5%). Double plating of non-unions achieved excellent osseous union rates (98.5%).Conclusions: The literature provides evidence for superior outcomes when using double plating in distal femoral fractures, periprosthetic fractures and femoral non-unions. Some evidence suggests that the use of double plating of femoral fractures in polytraumatised patients may be beneficial over other types of fracture fixation.Level of evidence: IV.

Verified
Journal Article
Open access
PDF file
MLMoritz Friedrich Lodde
Moritz Friedrich Lodde
J. Christoph KatthagenJ. Christoph Katthagen
J. Christoph Katthagen
CSClemens Schopper
Clemens Schopper
IZIvan Zderic
Ivan Zderic
RRRobert Geoff Richards
Robert Geoff Richards
René HartensuerRené Hartensuer
René Hartensuer
Background: Incidence of pelvic ring fractures has increased over the past four decades, especially after low-impact trauma—classified as fragility fractures of the pelvis (FFP). To date, there is a lack of biomechanical evidence for the superiority of one existing fixation technique over another. An FFP type IIc was simulated in 50 artificial pelvises, assigned to 5 study groups: Sacroiliac (SI) screw, SI screw plus supra-acetabular external fixator, SI screw plus plate, SI screw plus retrograde transpubic screw, or S1/S2 ala–ilium screws. The specimens were tested under progressively increasing cyclic loading. Axial stiffness and cycles to failure were analysed. Displacement at the fracture sites was evaluated, having been continuously captured via motion tracking. Results: Fixation with SI screw plus plate and SI screw plus retrograde transpubic screw led to higher stability than the other tested techniques. The S1/S2 ala–ilium screws were more stable than the SI screw or the SI screw plus external fixator. Conclusions: In cases with displaced fractures, open reduction and plate fixation provides the highest stability, whereas in cases where minimally invasive techniques are applicable, a retrograde transpubic screw or S1/S2 ala–ilium screws can be considered as successful alternative treatment options.

17 August 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
René HartensuerRené Hartensuer
René Hartensuer
MLMoritz Friedrich Lodde
Moritz Friedrich Lodde
JKJonas Keller
Jonas Keller
MEMaria Eveslage
Maria Eveslage
JSJosef Stolberg-Stolberg
Josef Stolberg-Stolberg
MRMichael Johannes Raschke
Michael Johannes Raschke
Background: Minimally invasive sacroiliac-screw (SI-screw) fixation of the pelvis is used in energy trauma (Arbeitsgemeinschaft für Osteosynthesefragen (AO) classified) and fragility fractures (Fragility Fracture of the Pelvis (FFP) classified). However, available clinical data are based on small case series and biomechanical data seem to be contradictory. Methods: The present single center retrospective cohort study investigated percutaneous SI-screw fixation and augmentation over 15 years. Groups were compared concerning the general epidemiological data, mobilization, complication rates, duration of stay, and safety of SI-screw insertion. Multivariable analyses were performed using logistic regression. Results: Between 2005 and March 2020, 448 patients with 642 inserted SI-screws were identified. Iatrogenic neurological impairment was documented in 2.47% and correlated with screw misplacement. There was an increased complication risk in patients with AO type C over patients with AO type B and in FFP II over FFP III/IV patients. Cement-augmented FFP patients showed a 25% reduced stay in hospital and a reduced complication risk. Cement-associated complications were seen in 22% without correlation to neurologic impairment. Conclusions: The present study confirms the safety and usability of percutaneous SI-screw fixation, despite specific risks. Cement augmentation seems to reduce the complication risk in FFP patients and shorten hospital stay for some reasons, without increased specific complications or correlated neurological impairment.

8 October 2020 in Der Unfallchirurg
Verified
Journal Article
Closed access
PDF file
MLMoritz Friedrich Lodde
Moritz Friedrich Lodde
JKJ. Christoph Katthagen
J. Christoph Katthagen
OROliver Riesenbeck
Oliver Riesenbeck
MRMichael J. Raschke
Michael J. Raschke
René HartensuerRené Hartensuer
René Hartensuer

16 December 2021 in Medicina
Verified
Journal Article
Open access
PDF file
MLMoritz Friedrich Lodde
Moritz Friedrich Lodde
J. Christoph KatthagenJ. Christoph Katthagen
J. Christoph Katthagen
CSClemens Schopper
Clemens Schopper
IZIvan Zderic
Ivan Zderic
RRRobert Geoff Richards
Robert Geoff Richards
René HartensuerRené Hartensuer
René Hartensuer
Background and Objectives: The stability of the pelvic ring mainly depends on the integrity of its posterior part. Percutaneous sacroiliac (SI) screws are widely implanted as standard of care treatment. The main risk factors for their fixation failure are related to vertical shear or transforaminal sacral fractures. The aim of this study was to compare the biomechanical performance of fixations using one (Group 1) or two (Group 2) standard SI screws versus one SI screw with bone cement augmentation (Group 3). Materials and Methods: Unstable fractures of the pelvic ring (AO/OTA 61-C1.3, FFP IIc) were simulated in 21 artificial pelvises by means of vertical osteotomies in the ipsilateral anterior and posterior pelvic ring. A supra-acetabular external fixator was applied to address the anterior fracture. All specimens were tested under progressively increasing cyclic loading until failure, with monitoring by means of motion tracking. Fracture site displacement and cycles to failure were evaluated. Results: Fracture displacement after 500 cycles was lowest in Group 3 (0.76 cm [0.30] (median [interquartile range, IQR])) followed by Group 1 (1.42 cm, [0.21]) and Group 2 (1.42 cm [1.66]), with significant differences between Groups 1 and 3, p = 0.04. Fracture displacement after 1000 cycles was significantly lower in Group 3 (1.15 cm [0.37]) compared to both Group 1 (2.19 cm [2.39]) and Group 2 (2.23 cm [3.65]), p ≤ 0.04. Cycles to failure (Group 1: 3930 ± 890 (mean ± standard deviation), Group 2: 3676 ± 348, Group 3: 3764 ± 645) did not differ significantly between the groups, p = 0.79. Conclusions: In our biomechanical setup cement augmentation of one SI screw resulted in significantly less displacement compared to the use of one or two SI screws. However, the number of cycles to failure was not significantly different between the groups. Cement augmentation of one SI screw seems to be a useful treatment option for posterior pelvic ring fixation, especially in osteoporotic bone.

28 October 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MLMoritz Friedrich Lodde
Moritz Friedrich Lodde
J. Christoph KatthagenJ. Christoph Katthagen
J. Christoph Katthagen
CSClemens Schopper
Clemens Schopper
IZIvan Zderic
Ivan Zderic
RRRobert Geoff Richards
Robert Geoff Richards
René HartensuerRené Hartensuer
René Hartensuer
Background: Fractures of the four anterior pubic rami are described as “straddle fractures”. The aim of this study was to compare biomechanical anterior plating (group 1) versus the bilateral use of retrograde transpubic screws (group 2). Methods: A straddle fracture was simulated in 16 artificial pelvises. All specimens were tested under progressively increasing cyclic loading, with monitoring by means of motion tracking. Results: Axial stiffness did not differ significantly between the groups, p = 0.88. Fracture displacement after 1000–4000 cycles was not significantly different between the groups, p ≥ 0.38; however, after 5000 cycles it was significantly less in the retrograde transpubic screw group compared to the anterior plating group, p = 0.04. No significantly different flexural rotations were detected between the groups, p ≥ 0.32. Moreover, no significant differences were detected between the groups with respect to their cycles to failure and failure loads, p = 0.14. Conclusion: The results of this biomechanical study reveal less fracture displacement in the retrograde transpubic screw group after long-term testing with no further significant difference between anterior plating and bilateral use of retrograde transpubic screws. While the open approach using anterior plating allows for better visualization of the fracture site and open reduction, the use of bilateral retrograde transpubic screws, splinting the fracture, presents a minimally invasive and biomechanically stable technique.