Jean-Jacques Rouby

Prof. Dr. Jean-Jacques Rouby

Multidisciplinary Intensive Care Unit, Department of Anaesthesiology and Critical Care, La Pitié-Salpêtrière Hospital, Assistance Publique Hôpitaux de Paris, Medicine Sorbonne University, Paris, France

Research Focus & Metrics

Academic Career Length

49Years (1978-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2012 in Intensive Care Medicine
Verified
Journal Article
Closed access
PDF file
I(International Liaison Committee on Lung Ultrasound (ILC-LUS) for the International Consensus Conference on Lung Ultrasound (ICC-LUS)
International Liaison Committee on Lung Ultrasound (ILC-LUS) for the International Consensus Conference on Lung Ultrasound (ICC-LUS)
GVGiovanni Volpicelli
Giovanni Volpicelli
MEMahmoud Elbarbary
Mahmoud Elbarbary
MBMichael Blaivas
Michael Blaivas
DLDaniel A. Lichtenstein
Daniel A. Lichtenstein
TPTomislav Petrovic
Tomislav Petrovic

1 January 2004 in Anesthesiology
Verified
Journal Article
Closed access
DLDaniel Lichtenstein
Daniel Lichtenstein
IGIvan Goldstein
Ivan Goldstein
EMEric Mourgeon
Eric Mourgeon
PCPhilippe Cluzel
Philippe Cluzel
PGPhilippe Grenier
Philippe Grenier
Jean-Jacques RoubyJean-Jacques Rouby
Jean-Jacques Rouby
Background: Lung auscultation and bedside chest radiography are routinely used to assess the respiratory condition of ventilated patients with acute respiratory distress syndrome (ARDS). Clinical experience suggests that the diagnostic accuracy of these procedures is poor. Methods: This prospective study of 32 patients with ARDS and 10 healthy volunteers was performed to compare the diagnostic accuracy of auscultation, bedside chest radiography, and lung ultrasonography with that of thoracic computed tomography. Three pathologic entities were evaluated in 384 lung regions (12 per patient): pleural effusion, alveolar consolidation, and alveolar-interstitial syndrome. Results: Auscultation had a diagnostic accuracy of 61% for pleural effusion, 36% for alveolar consolidation, and 55% for alveolar-interstitial syndrome. Bedside chest radiography had a diagnostic accuracy of 47% for pleural effusion, 75% for alveolar consolidation, and 72% for alveolar-interstitial syndrome. Lung ultrasonography had a diagnostic accuracy of 93% for pleural effusion, 97% for alveolar consolidation, and 95% for alveolar-interstitial syndrome. Lung ultrasonography, in contrast to auscultation and chest radiography, could quantify the extent of lung injury. Interobserver agreement for the ultrasound findings as assessed by the kappa statistic was satisfactory: 0.74, 0.77, and 0.73 for detection of alveolar-interstitial syndrome, alveolar consolidation, and pleural effusion, respectively. Conclusions: At the bedside, lung ultrasonography is highly sensitive, specific, and reproducible for diagnosing the main lung pathologic entities in patients with ARDS and can be considered an attractive alternative to bedside chest radiography and thoracic computed tomography.

1 February 2011 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
BBBelaïd Bouhemad
Belaïd Bouhemad
HBHélène Brisson
Hélène Brisson
MLMorgan Le-Guen
Morgan Le-Guen
CACharlotte Arbelot
Charlotte Arbelot
QLQin Lu
Qin Lu
Jean-Jacques RoubyJean-Jacques Rouby
Jean-Jacques Rouby
Rationale: In the critically ill patients, lung ultrasound (LUS) is increasingly being used at the bedside for assessing alveolar-interstitial syndrome, lung consolidation, pneumonia, pneumothorax, and pleural effusion. It could be an easily repeatable noninvasive tool for assessing lung recruitment. Objectives: Our goal was to compare the pressure–volume (PV) curve method with LUS for assessing positive end-expiratory pressure (PEEP)-induced lung recruitment in patients with acute respiratory distress syndrome/acute lung injury (ARDS/ALI). Methods: Thirty patients with ARDS and 10 patients with ALI were prospectively studied. PV curves and LUS were performed in PEEP 0 and PEEP 15 cm H2O. PEEP-induced lung recruitment was measured using the PV curve method. Measurements and Main Results: Four LUS entities were defined: consolidation; multiple, irregularly spaced B lines; multiple coalescent B lines; and normal aeration. For each of the 12 lung regions examined, PEEP-induced ultrasound changes were measured, and an ultrasound reaeration score was calculated. A highly significant correlation was found between PEEP-induced lung recruitment measured by PV curves and ultrasound reaeration score (Rho = 0.88; P < 0.0001). An ultrasound reaeration score of +8 or higher was associated with a PEEP-induced lung recruitment greater than 600 ml. An ultrasound lung reaeration score of +4 or less was associated with a PEEP-induced lung recruitment ranging from 75 to 450 ml. A statistically significant correlation was found between LUS reaeration score and PEEP-induced increase in PaO2 (Rho = 0.63; P < 0.05). Conclusions: PEEP-induced lung recruitment can be adequately estimated with bedside LUS. Because LUS cannot assess PEEP-induced lung hyperinflation, it should not be the sole method for PEEP titration.

1 January 2007 in Critical Care
Verified
Journal Article
Open access
PDF file
Jean-Jacques RoubyJean-Jacques Rouby
Jean-Jacques Rouby
FFFabio Ferrari
Fabio Ferrari
BBBélaïd Bouhemad
Bélaïd Bouhemad
QLQin Lu
Qin Lu
In patients with acute respiratory distress syndrome, positive end-expiratory pressure is associated with alveolar recruitment and lung hyperinflation despite the administration of a low tidal volume. The best positive end-expiratory pressure should correspond to the best compromise between recruitment and distension, a condition that coincides with the best respiratory elastance.

1 July 2012 in Critical Care Medicine
Verified
Journal Article
Closed access
ASAlexis Soummer
Alexis Soummer
SPSébastien Perbet
Sébastien Perbet
HBHélène Brisson
Hélène Brisson
CACharlotte Arbelot
Charlotte Arbelot
JCJean-Michel Constantin
Jean-Michel Constantin
LGLung Ultrasound Study Group
Lung Ultrasound Study Group
Objective: Postextubation distress after a successful spontaneous breathing trial is associated with increased morbidity and mortality. Predicting postextubation distress is therefore a major issue in critically ill patients. To assess whether lung derecruitment during spontaneous breathing trial assessed by lung ultrasound is predictive of postextubation distress. Design and Setting: Prospective study in two multidisciplinary intensive care units within University Hospital. Patients and Methods: One hundred patients were included in the study. Lung ultrasound, echocardiography, and plasma B-type natriuretic peptide levels were determined before and at the end of a 60-min spontaneous breathing trial and 4 hrs after extubation. To quantify lung aeration, a lung ultrasound score was calculated. Patients were followed up to hospital discharge. Measurements and Main Results: Fourteen patients failed the spontaneous breathing trial, 86 were extubated, 57 were definitively weaned (group 1), and 29 suffered from postextubation distress (group 2). Loss of lung aeration during the successful spontaneous breathing trial was observed only in group 2 patients: lung ultrasound scores increased from 15 [13;17] to 19 [16; 21] (p < .01). End-spontaneous breathing trial lung ultrasound scores were significantly higher in group 2 than in group 1 patients: 19 [16;21] vs. 10 [7;13], respectively (p < .001) and predicted postextubation distress with an area under the receiver operating characteristic curve of 0.86. Although significantly higher in group 2, B-type natriuretic peptide and echocardiography cardiac filling pressures were not clinically helpful in predicting postextubation distress. Conclusion: Lung ultrasound determination of aeration changes during a successful spontaneous breathing trial may accurately predict postextubation distress.

1 August 2015 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
AMAntoine Monsel
Antoine Monsel
YZYing-Gang Zhu
Ying-Gang Zhu
SGStephane Gennai
Stephane Gennai
QHQi Hao
Qi Hao
SHShuling Hu
Shuling Hu
JLJae W. Lee
Jae W. Lee
Rationale: Microvesicles (MVs) are anuclear fragments of cells released from the endosomal compartment or shed from surface membranes. We and other investigators demonstrated that MVs released by mesenchymal stem cells (MSCs) were as effective as the cells themselves in inflammatory injuries, such as after endotoxin-induced acute lung injury. However, the therapeutic effects of MVs in an infectious model of acute lung injury remain unknown. Objectives: We investigated the effects of human MSC MVs on lung inflammation, protein permeability, bacterial clearance, and survival after severe bacterial pneumonia. Methods: We tested the effects of MVs derived from human MSCs on Escherichia coli pneumonia in mice. We also studied the interactions between MVs and human monocytes and human alveolar epithelial type 2 cells. Measurements and Main Results: Administration of MVs derived from human MSCs improved survival in part through keratinocyte growth factor secretion and decreased the influx of inflammatory cells, cytokines, protein, and bacteria in mice injured with bacterial pneumonia. In primary cultures of human monocytes or alveolar type 2 cells, the uptake of MVs was mediated by CD44 receptors, which were essential for the therapeutic effects. MVs enhanced monocyte phagocytosis of bacteria while decreasing inflammatory cytokine secretion and increased intracellular ATP levels in injured alveolar epithelial type 2 cells. Prestimulation of MSCs with a toll-like receptor 3 agonist further enhanced the therapeutic effects of the released MVs. Conclusions: MVs derived from human MSCs were as effective as the parent stem cells in severe bacterial pneumonia.