Jan-Christoph Zarges

Dr. Jan-Christoph Zarges

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2021 in Polymers
Verified
Journal Article
Open access
PDF file
RZRafal Zurawik
Rafal Zurawik
JVJulia Volke
Julia Volke
JZJan-Christoph Zarges
Jan-Christoph Zarges
HHHans-Peter Heim
Hans-Peter Heim
During injection molding of short glass fiber reinforced composites, a complex structure is formed due to the fiber movement. The resulting fiber orientation can be predicted using various simulation models. However, the models are known to have inadequacies andthe influence of process and model parameters is not clearly and comprehensively described. In this study, the aforementioned model and process parameters are investigated to determine the dependencies of the individual influences on the real and simulated fiber orientation. For this purpose, specimens are injection molded at different process parameters. Representative regions of the specimens are measured using X-ray microtomography and dynamic image analysis to determine the geometric properties of the fibers as well as their orientations. Furthermore, simulations are performed with the simulation software Moldflow® using different mesh types and densities as well as varying parameters of the MRD model to represent the real fiber orientations. The results show that different orientation areas arise in the samples, which cannot be represented with a simulation varying only one parameter. Several simulations must be carried out in order to represent flow regions occurring in the specimen as realistically as possible.

18 August 2023 in Polymers
Verified
Journal Article
Open access
PDF file
NKNatalie Krug
Natalie Krug
JZJan-Christoph Zarges
Jan-Christoph Zarges
HHHans-Peter Heim
Hans-Peter Heim
In order to encourage the substitution of petrochemical polymers in medical technology with sustainable, bio-based materials, there is an urgent need for further investigations, especially data regarding their sterility performance. Within the scope of the investigations, selected material properties of poly-L-lactic-acid (PLLA), a specific type of poly(lactic-acid) (PLA), were analyzed before and after sterilization (using ethylene oxide or gamma irradiation) in order to investigate deviations in its chemical structure, wettability, optical, and mechanical properties. In particular, parameters such as molecular weight, complex viscosity, tensile strength, water contact angle, and color were discussed. Sterilization temperatures close to the glass transition of PLA, high humidity, and interactions with the ethylene oxide molecules have resulted in an increase in crystallinity, a decrease in elongation at break, and in some cases, a variation in wettability. As a consequence of exposure to high-energy radiation, the material’s toughness is reduced due to chain scission, which is manifested through a decrease in molecular weight, an increase in crystallinity, and a partial change in surface energy. For the selected PLLA-materials (Luminy® L130, NP HT 202, and NP HT 203), ethylene oxide sterilization resulted in a comparatively minor variation in the characteristics behavior, and was chosen as the preferred method.


25 July 2024 in Materials
Verified
Journal Article
Open access
PDF file
VGVictoria Goetjes
Victoria Goetjes
JZJan-Christoph Zarges
Jan-Christoph Zarges
HHHans-Peter Heim
Hans-Peter Heim
For the application of poly(lactic acid) (PLA) and PLA/starch composites in technical components such as toys, it is essential to know their degradation behavior under relevant application conditions in a hydrothermal environment. For this purpose, composites made from PLA and native potato starch were produced using twin-screw extruders and then processed into test specimens, which were then subjected to various one-week ageing processes with varying temperatures (23, 50, 70, 90 °C) and humidity levels (10, 50, 75, 90%). This was followed by mechanical characterization (tensile test) and identification of degradation using Gel Permeation Chromatography (GPC), Thermogravimetric Analysis (TGA), Fourier Transform Infrared Spectroscopy (FTIR), and Nuclear Magnetic Resonance spectroscopy (NMR). With increasing temperature and humidity, there was a clear degradation of the PLA, which could be reduced or slowed down by adding 50 wt.% starch, due to increased crystallinity. Hydrolysis was identified as the main degradation mechanism for PLA and PLA/starch composites, especially above the glass transition temperature, with thermo-oxidative degradation also playing a subordinate role. Both hydrolytic degradation and thermo-oxidative degradation led to a reduction in mechanical properties such as tensile strength.

13 May 2021 in Polymers
Verified
Journal Article
Open access
PDF file
SMSelim Mrzljak
Selim Mrzljak
ADAlexander Delp
Alexander Delp
ASAndré Schlink
André Schlink
JZJan-Christoph Zarges
Jan-Christoph Zarges
DHDaniel Hülsbusch
Daniel Hülsbusch
Frank WaltherFrank Walther
Frank Walther
Short glass fiber reinforced plastics (SGFRP) offer superior mechanical properties compared to polymers, while still also enabling almost unlimited geometric variations of components at large-scale production. PA6-GF30 represents one of the most used SGFRP for series components, but the impact of injection molding process parameters on the fatigue properties is still insufficiently investigated. In this study, various injection molding parameter configurations were investigated on PA6-GF30. To take the significant frequency dependency into account, tension–tension fatigue tests were performed using multiple amplitude tests, considering surface temperature-adjusted frequency to limit self-heating. The frequency adjustment leads to shorter testing durations as well as up to 20% higher lifetime under fatigue loading. A higher melt temperature and volume flow rate during injection molding lead to an increase of 16% regarding fatigue life. In situ X-ray microtomography analysis revealed that this result was attributed to a stronger fiber alignment with larger fiber lengths in the flow direction. Using digital volume correlation, differences of up to 100% in local strain values at the same stress level for different injection molding process parameters were identified. The results prove that the injection molding parameters have a high influence on the fatigue properties and thus offer a large optimization potential, e.g., with regard to the component design.

23 March 2023 in Polymers
Verified
Journal Article
Open access
PDF file
CFCelia Katharina Falkenreck
Celia Katharina Falkenreck
NGNicole Gemmeke
Nicole Gemmeke
JZJan-Christoph Zarges
Jan-Christoph Zarges
HHHans-Peter Heim
Hans-Peter Heim
With regard to the sustainability and biological origin of plastic components, regenerated cellulose fiber (RCF)-reinforced polymers are expected to replace other composites in the future. For use under severe conditions, for example, as a housing in the engine compartment, the resistance of the composites and the impact on the fiber and fiber-matrix adhesion must be investigated. Composites of bio-polyamide with a reinforcement of 20 wt.% RCF were compounded using a twin-screw extruder. The test specimens were manufactured with an injection molding machine and aged under conditions of high humidity at 90% r. H, a high temperature of 70 °C, and water storage using a water temperature of 23 °C for 504 h. Mechanical tests, single-fiber tensile tests (SFTT), single-fibre pull-out tests (SFPT), and optical characterization revealed significant changes in the properties of the composites. The results of the SFPT show that accelerated aging had a significant effect on the bio-polymer and an even stronger effect on the fiber, as the single-fiber tensile strength decreased by 27.5%. Supplementary notched impact strength tests revealed a correlation of the impact strength and the accelerated aging of the RCF-reinforced composites. In addition, it could be verified that the tensile strength also decreased at about 37% due to the aging effect on the RCF and a lowered fiber-matrix adhesion. The largest aging impact was on the Young’s modulus with a decrease of 45% due to the accelerated aging. In summary, the results show that the strengthening effect with 20 wt.% RCF was highly decreased subsequent to the accelerated aging due to hydrolysis and debonding because of the shrinkage and swelling of the matrix and fiber. These scientific findings are essential, as it is important to ensure that this bio-based material used in the automotive sector can withstand these stresses without severe degradation. This study provides information about the aging behavior of RCF-reinforced bio-based polyamide, which provides fundamental insights for future research.